Discrimination of hip fractures by quantitative ultrasound of the phalanges and the calcaneus and dual X-ray absorptiometry

被引:21
作者
Damilakis, J [1 ]
Papadokostakis, G
Pertsinakis, K
Maris, T
Dimitriou, P
Hadjipavlou, A
Gourtsoyiannis, N
机构
[1] Univ Crete, Fac Med, Dept Med Phys, Iraklion, Crete, Greece
[2] Univ Crete, Fac Med, Dept Orthoped, Iraklion, Crete, Greece
[3] Univ Athens, Fac Med, Dept Radiol, Athens, Greece
[4] Univ Crete, Fac Med, Dept Radiol, Iraklion, Crete, Greece
关键词
osteoporosis; hip fractures; QUS; DXA;
D O I
10.1016/j.ejrad.2004.01.023
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of the current study was to evaluate the ability of different techniques used for the assessment of bone status to discriminate between postmenopausal women with and without hip fracture. Fifty-one postmenopausal women (mean age 64.5 +/- 6.5) who had sustained a low energy hip fracture and 51 age-matched controls (mean age 64.6 +/- 6.0) were studied. Quantitative ultrasound (QUIS) assessment was carried out using the Ubis 3000 device capable of measuring broadband ultrasound attenuation (BUA) and speed of sound at the calcaneus (SOSC) and the Sunlight Omnisense device capable of estimating speed of sound at the phalanges (SOSp). Femoral neck bone mineral density (BMD) was assessed using dual X-ray absorptiometry. Correlations between QUS variables ranged from r = 0.35 to 0.72 and between QUS variables and BMD from r = 0.30 to 0.36. BMD was the best discriminator of hip fractures (odds ratio = 3.61, area under Curve = 0.824). All QUS variables were significant discriminators of hip fractures with odds ratios ranging from 1.88 to 2.63 and areas under the ROC curves ranging from 0.663 to 0.740. Among the QUS variables, the SOSp showed the best odds ratio and area under curve. Comparison between the areas under the ROC curve did not show any significant difference between SOSp, BUA and BMD. On the contrary, the difference between SOSC and BMD was significant (P < 0.05). In conclusion, BMD and QUS variables investigated in the current study were significant discriminators of hip fractures. The differentiation of the hip fractures by BMD was significantly better than that of BUA measured at the calcaneus. Moreover, BMD discriminated fractured patients better than BUA and SOSp, although the difference did not reach statistical significance. (C) 2004 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:268 / 272
页数:5
相关论文
共 24 条
[1]   RISK-FACTORS FOR HIP FRACTURE IN WHITE WOMEN [J].
CUMMINGS, SR ;
NEVITT, MC ;
BROWNER, WS ;
STONE, K ;
FOX, KM ;
ENSRUD, KE ;
CAULEY, JC ;
BLACK, D ;
VOGT, TM .
NEW ENGLAND JOURNAL OF MEDICINE, 1995, 332 (12) :767-773
[2]   Epidemiology and outcomes of osteoporotic fractures [J].
Cummings, SR ;
Melton, LJ .
LANCET, 2002, 359 (9319) :1761-1767
[3]   Effect of region of interest location on ultrasound measurements of the calcaneus [J].
Damilakis, J ;
Perisinakis, K ;
Vagios, E ;
Tsinikas, D ;
Gourtsoyiannis, N .
CALCIFIED TISSUE INTERNATIONAL, 1998, 63 (04) :300-305
[4]   Imaging ultrasonometry of the calcaneus: Dependence on calcaneal area [J].
Damilakis, J ;
Perisinakis, K ;
Gourtsoyiannis, N .
CALCIFIED TISSUE INTERNATIONAL, 2000, 67 (01) :24-28
[5]   Can radial bone mineral density and quantitative ultrasound measurements reduce the number of women who need axial density skeletal assessment? [J].
Damilakis, J ;
Papadokostakis, G ;
Perisinakis, K ;
Hadjipavlou, A ;
Gourtsoyiannis, N .
OSTEOPOROSIS INTERNATIONAL, 2003, 14 (08) :688-693
[6]   Ultrasound velocity through the cortex of phalanges, radius, and tibia in normal and osteoporotic a new multisite postmenopausal women using quantitative ultrasound device [J].
Damilakis, J ;
Papadokostakis, G ;
Vrahoriti, H ;
Tsagaraki, I ;
Perisinakis, K ;
Hadjipavlou, A ;
Gourtsoyiannis, N .
INVESTIGATIVE RADIOLOGY, 2003, 38 (04) :207-211
[7]   Effect of lifetime occupational physical activity on indices of bone mineral status in healthy postmenopausal women [J].
Damilakis, J ;
Perisinakis, K ;
Kontakis, G ;
Vagios, E ;
Gourtsoyiannis, N .
CALCIFIED TISSUE INTERNATIONAL, 1999, 64 (02) :112-116
[8]   Broadband ultrasound attenuation imaging: algorithm development and clinical assessment of a region growing technique [J].
Damilakis, J ;
Stratakis, J ;
Perisinakis, K ;
Gourtsoyiannis, N .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (02) :315-325
[9]   Osteoporosis: Association of recent fractures with quantitative US findings [J].
Gluer, CC ;
Cummings, SR ;
Bauer, DC ;
Stone, K ;
Pressman, A ;
Mathur, A ;
Genant, HK .
RADIOLOGY, 1996, 199 (03) :725-732
[10]   Quantitative US of the calcaneus: Cutoff levels for the distinction of healthy and osteoporotic individuals [J].
Grampp, S ;
Henk, C ;
Lu, Y ;
Krestan, C ;
Resch, H ;
Kainberger, F ;
Youssefzadeh, S ;
Vorbeck, F ;
Imhof, H .
RADIOLOGY, 2001, 220 (02) :400-405