All-inside meniscal repair devices - An experimental study in the goat model

被引:27
作者
Miller, MD
Kline, AJ
Jepsen, KG
机构
[1] Univ Virginia, Dept Orthopaed Surg, Sch Med, Charlottesville, VA 22908 USA
[2] Wilford Hall USAF Med Ctr, Lackland AFB, TX 78236 USA
关键词
knee; meniscus; repair; all-inside;
D O I
10.1177/0363546503260068
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Although the use of "all-inside" absorbable meniscal repair devices has become popular, numerous complications have been reported. The authors applied their well-established goat model to evaluate three "all-inside" meniscal repair devices. Methods: A "tear" was created in the medial meniscus of both knees in 26 goats. The animals were randomized into four groups, and the meniscus was treated as follows: (A) meniscal repair with Mitek Fastner, (B) meniscal repair with BioStinger, (C) meniscal repair with Mitek Clearfix Screw, and (D) no repair. All animals were sacrificed at 6 months postoperatively, and all specimens were carefully evaluated and results recorded and compared with historical results of meniscal repair with suture in this same animal model. Results: Meniscal repair results with all three all-inside devices studied were inferior to suture repair. Chondral injury was present in 75% to 100% of repairs with all-inside devices and none of the control specimens. Discussion/Conclusion: Although new all-inside meniscal repair devices are relatively quick and easy, results may not be as good as with traditional suture techniques. The high rate of chondral injury associated with these devices in the goat model is worrisome for chondral damage in humans, especially in patients with smaller or tighter knees.
引用
收藏
页码:858 / 862
页数:5
相关论文
共 28 条
[1]
Biodegradable arrows for arthroscopic repair of meniscal tears [J].
Al-Othman, AA .
INTERNATIONAL ORTHOPAEDICS, 2002, 26 (04) :247-249
[2]
Chondral injury following meniscal repair with a biodegradable implant [J].
Anderson, K ;
Marx, RG ;
Hannafin, J ;
Warren, RF .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2000, 16 (07) :749-753
[3]
Meniscal repair devices [J].
Barber, FA ;
Herbert, MA .
ARTHROSCOPY, 2000, 16 (06) :613-618
[4]
Pull-out strength and stiffness of meniscal repair using absorbable arrows or Ti-Cron vertical and horizontal loop sutures [J].
Boenisch, UW ;
Faber, KJ ;
Ciarelli, M ;
Steadman, JR ;
Arnoczky, SP .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1999, 27 (05) :626-631
[5]
Broken arrow: A complication of meniscal repair [J].
Calder, SJ ;
Myers, PT .
ARTHROSCOPY, 1999, 15 (06) :651-652
[6]
DARVIN GF, 1997, ARTHROSCOPY, V13, P296
[7]
Clinical evaluation of meniscus repair with a bioabsorbable arrow: a 2-to 3-year follow-up study [J].
Ellermann, A ;
Siobold, R ;
Buelow, JU ;
Sobau, C .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2002, 10 (05) :289-293
[8]
KNEE JOINT CHANGES AFTER MENISCECTOMY [J].
FAIRBANK, TJ .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1948, 30 (04) :664-670
[9]
Outcomes after meniscal repair using the meniscus arrow in knees undergoing concurrent anterior cruciate ligament reconstruction [J].
Gill, SS ;
Diduch, DR .
ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2002, 18 (06) :569-577
[10]
Cystic hematoma formation following use of a biodegradable arrow for meniscal repair [J].
Hechtman, KS ;
Uribe, JW .
ARTHROSCOPY, 1999, 15 (02) :207-210