Capillary isoelectric focusing-mass spectrometry: analysis of protein mixtures from human body fluids

被引:26
作者
Clarke, NJ
Naylor, S
机构
[1] Mayo Clin & Mayo Fdn, Dept Biochem & Mol Biol, Biomed Mass Spectrometry & Funct Proteom Facil, Rochester, MN 55905 USA
[2] Mayo Clin & Mayo Fdn, Div Biomol Engn, Dept Mol Pharmacol & Expt Therapeut, Rochester, MN 55905 USA
[3] Mayo Clin & Mayo Fdn, Div Biomol Engn, Clin Pharmacol Unit, Rochester, MN 55905 USA
关键词
D O I
10.1002/bmc.159
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Isoelectric focusing within a fused silica capillary (cIEF) has proved to be a powerful and practical method for high-resolution separation of analytes from complex biological mixtures. This technique overcomes many of the problems of isoelectric focusing within slab gel media. However current cIEF systems commonly utilize UV detection which limits the detail of analyte structural information that is obtained durin analysis. The use of mass spectrometry (MS) as the detection system provides much greater structural information about the detected analytes allowing accurate relative molecular mass (M-r) determination for proteins and polypeptides. We have constructed a cIEF-MS interface and compared the separation of standard proteins analyzed by cIEF-UV with cIEF-MS. This allowed rapid optimization of the cIEF-MS system performance. Further we have demonstrated the use of MS as a detection system provides accurate M-r information and can provide analyte modification details. These factors increase the likelihood of absolute identification for physiological proteins within complex in vivo-derived mixtures. To demonstrate the value of cIEF-MS in such analyses we have undertaken an examination of cerebrospinal fluid (CSF), and tentatively identified a number of constituent proteins. We have also analyzed whole blood from control and diabetic patients. We show that glycated alpha- and beta- chains of hemoglobin are found in almost equal abundance in diabetic patient blood. From these results we suggest cIEF-MS is an efficient and useful tool for the separation and examination of in vivo-derived analytes within physiological fluids. Copyright (C) 2002 John Wiley Sons, Ltd.
引用
收藏
页码:287 / 297
页数:11
相关论文
共 38 条
[1]  
BHOWN AS, 1990, HDB PROTEINS, P187
[2]  
BUNN HF, 1981, DIABETES, V30, P613
[3]   THE USE OF CAPILLARY ELECTROPHORESIS FOR THE DETERMINATION OF HEMOGLOBIN-VARIANTS [J].
CASTAGNOLA, M ;
MESSANA, I ;
CASSIANO, L ;
RABINO, R ;
ROSSETTI, DV ;
GIARDINA, B .
ELECTROPHORESIS, 1995, 16 (08) :1492-1498
[4]   On-line desalting of physiologically derived fluids in conjunction with capillary isoelectric focusing-mass spectrometry [J].
Clarke, NJ ;
Tomlinson, AJ ;
Naylor, S .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1997, 8 (07) :743-748
[5]   Capillary isoelectric focusing of physiologically derived proteins with on-line desalting of isotonic salt concentrations [J].
Clarke, NJ ;
Tomlinson, AJ ;
Schomburg, G ;
Naylor, S .
ANALYTICAL CHEMISTRY, 1997, 69 (14) :2786-2792
[6]   Capillary isoelectric focusing of hemoglobin variants in the pediatric clinical laboratory [J].
Hempe, JM ;
Granger, JN ;
Craver, RD .
ELECTROPHORESIS, 1997, 18 (10) :1785-1795
[7]  
Hempe JM, 2000, ELECTROPHORESIS, V21, P743, DOI 10.1002/(SICI)1522-2683(20000301)21:4<743::AID-ELPS743>3.3.CO
[8]  
2-T
[9]   ADAPTATION OF THE EQUIPMENT FOR HIGH-PERFORMANCE ELECTROPHORESIS TO ISOELECTRIC-FOCUSING [J].
HJERTEN, S ;
ZHU, MD .
JOURNAL OF CHROMATOGRAPHY, 1985, 346 (OCT) :265-270
[10]   Characterization of cellobiohydrolase I (Cel7A) glycoforms from extracts of Trichoderma reesei using capillary isoelectric focusing and electrospray mass spectrometry [J].
Hui, JPM ;
Lanthier, P ;
White, TC ;
McHugh, SG ;
Yaguchi, M ;
Roy, R ;
Thibault, P .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2001, 752 (02) :349-368