Evaluation of the radiation pattern of a split aperture linear phased array for high frequency imaging

被引:6
作者
Talman, JR [1 ]
Lockwood, GR [1 ]
机构
[1] Cleveland Clin Fdn, Dept Biomed Engn ND20, Cleveland, OH 44195 USA
关键词
Acoustic arrays - Diffraction gratings - Medical imaging - Signal receivers - Transmitters - Ultrasonic transducers;
D O I
10.1109/58.818754
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Developing transducer arrays for high frequency medical imaging is complicated because of the extremely small size and spacing of the array elements. For example, a 50 MHz linear phased array requires a center-to-center spacing of only 15 mu m tone-half wavelength in water) to avoid the formation of grating lobes in the radiation pattern of the array. Fabricating an array with these dimensions is difficult using conventional technology. A split aperture design that permits much larger element spacing (3 to 4 times) while avoiding the formation of grating lobes is described. The 3-D radiation pattern of a 1.9 x 1.4 mm, 50-MHz split aperture linear phased array with 33 transmit elements and 33 receive elements has been evaluated theoretically. The azimuthal beam width is 90 mu m at a distance of 4.0 mm. Grating lobes are suppressed by at least 60 dB at distances > 4.0 mm (similar to f/2). The elevation beam width is 220 mu m at 4.0 mm, and a useful depth of field over the axial range from 4 to 10 mm is obtained.
引用
收藏
页码:117 / 124
页数:8
相关论文
共 11 条
[1]  
BOURRIOT N, 1997 IEEE ULTR S P, V2, P113
[2]   Broad-bandwidth radiation patterns of sparse two-dimensional vernier arrays [J].
Brunke, SS ;
Lockwood, GR .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1997, 44 (05) :1101-1109
[3]   CHARACTERIZATION OF LEAD ZIRCONATE TITANATE CERAMICS FOR USE IN MINIATURE HIGH-FREQUENCY (20-80 MHZ) TRANSDUCERS [J].
FOSTER, FS ;
RYAN, LK ;
TURNBULL, DH .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1991, 38 (05) :446-453
[4]   ULTRASOUND TRANSDUCERS FOR PULSE-ECHO MEDICAL IMAGING [J].
HUNT, JW ;
ARDITI, M ;
FOSTER, FS .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1983, 30 (08) :453-481
[5]   A 100-MHZ ULTRASONIC TRANSDUCER ARRAY USING ZNO THIN-FILMS [J].
ITO, Y ;
KUSHIDA, K ;
SUGAWARA, K ;
TAKEUCHI, H .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1995, 42 (02) :316-324
[6]   Optimizing the radiation pattern of sparse periodic linear arrays [J].
Lockwood, GR ;
Li, PC ;
ODonnell, M ;
Foster, FS .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1996, 43 (01) :7-14
[7]  
LUKACS M, P SPIE, V3341, P272
[8]  
MARION JB, 1965, CLASSICAL ELECTROMAG, P394
[9]   Synthetic phased arrays for intraluminal imaging of coronary arteries [J].
ODonnell, M ;
Eberle, MJ ;
Stephens, DN ;
Litzza, JL ;
SanVicente, K ;
Shapo, BM .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1997, 44 (03) :714-721
[10]  
Ritter T, 1998, ULTRASON, P1851, DOI 10.1109/ULTSYM.1998.765312