Synthetic phased arrays for intraluminal imaging of coronary arteries

被引:89
作者
ODonnell, M
Eberle, MJ
Stephens, DN
Litzza, JL
SanVicente, K
Shapo, BM
机构
[1] UNIV MICHIGAN,DEPT BIOMED ENGN,ANN ARBOR,MI 48109
[2] ENDOSON CORP,RANCHO CORDOVA,CA 95670
基金
美国国家卫生研究院;
关键词
D O I
10.1109/58.658335
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A 64-element, high efficiency, ceramic piezoelectric array transducer operating at 20 MHz has been constructed for ultrasonic intraluminal imaging. The array is mounted on the surface of a 1,2 mm diameter catheter appropriate for coronary artery applications. Integrated into the catheter tip is a custom analog chip set permitting complete data capture from the array. That is, on each firing any combination of array elements can be selected independently as transmitter or receiver. Using data acquired in this way, a complete phased array aperture (i,e., independent transmit and receive apertures) can be synthesized. Reconstruction hardware based an a custom application specific integrated circuit (ASIC) has been designed and built to produce real-time images. Beam forming coefficients are derived using an optimal filtering approach accounting for the circular geometry of the array. Simulated and measured beam patterns for this system are compared. In addition, images of coronary anatomy acquired with the real-time system are displayed demonstrating the marked image quality improvement compared to previous synthetic aperture intraluminal systems.
引用
收藏
页码:714 / 721
页数:8
相关论文
共 15 条
  • [1] CMOS CHIP FOR INVASIVE ULTRASOUND IMAGING
    BLACK, WC
    STEPHENS, DN
    [J]. IEEE JOURNAL OF SOLID-STATE CIRCUITS, 1994, 29 (11) : 1381 - 1387
  • [2] Bom N, 1989, Int J Card Imaging, V4, P79, DOI 10.1007/BF01745137
  • [3] BOMMER WJ, 1995, CIRCULATION, V92, P1
  • [4] Hodgson J M, 1989, Int J Card Imaging, V4, P187, DOI 10.1007/BF01745149
  • [5] EVALUATIONAL SPATIAL COMPOUNDING
    LI, PC
    ODONNELL, M
    [J]. ULTRASONIC IMAGING, 1994, 16 (03) : 176 - 189
  • [6] LOCKWOOD GR, P 1990 IEEE ULTR S, P1409
  • [7] FEASIBILITY OF HIGH-RESOLUTION, INTRAVASCULAR ULTRASONIC-IMAGING CATHETERS
    MEYER, CR
    CHIANG, EH
    FECHNER, KP
    FITTING, DW
    WILLIAMS, DM
    BUDA, AJ
    [J]. RADIOLOGY, 1988, 168 (01) : 113 - 116
  • [8] ULTRASOUND GUIDANCE OF PALMAZ-SCHATZ INTRACORONARY STENTING WITH A COMBINED INTRAVASCULAR ULTRASOUND BALLOON CATHETER
    MUDRA, H
    KLAUSS, V
    BLASINI, R
    KROETZ, M
    RIEBER, J
    REGAR, E
    THEISEN, K
    [J]. CIRCULATION, 1994, 90 (03) : 1252 - 1261
  • [9] EFFICIENT SYNTHETIC APERTURE IMAGING FROM A CIRCULAR APERTURE WITH POSSIBLE APPLICATION TO CATHETER-BASED IMAGING
    ODONNELL, M
    THOMAS, LJ
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1992, 39 (03) : 366 - 380
  • [10] EXPERIMENTAL STUDIES ON AN EFFICIENT CATHETER ARRAY IMAGING-SYSTEM
    ODONNELL, M
    SHAPO, BM
    EBERLE, MJ
    STEPHENS, DN
    [J]. ULTRASONIC IMAGING, 1995, 17 (02) : 83 - 94