Halogenated Peptides as Internal Standards (H-PINS) INTRODUCTION OF AN MS-BASED INTERNAL STANDARD SET FOR LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY

被引:21
作者
Mirzaei, Hamid [1 ]
Brusniak, Mi-Youn [1 ]
Mueller, Lukas N. [2 ]
Letarte, Simon [1 ]
Watts, Julian D. [1 ]
Aebersold, Ruedi [1 ,2 ,3 ]
机构
[1] Inst Syst Biol, Seattle, WA 98103 USA
[2] ETH Honggerberg, Swiss Fed Inst Technol Zurich, ETH Zurich, Inst Mol Syst Biol, CH-8093 Zurich, Switzerland
[3] Univ Zurich, Fac Sci, CH-8006 Zurich, Switzerland
基金
美国国家卫生研究院;
关键词
CODED AFFINITY TAGS; ABSOLUTE QUANTIFICATION; QUANTITATIVE-ANALYSIS; PROTEOMICS; PROTEINS; IDENTIFICATION; DISCOVERY; MIXTURES; PROFILES; DATABASE;
D O I
10.1074/mcp.M800569-MCP200
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
As the application for quantitative proteomics in the life sciences has grown in recent years, so has the need for more robust and generally applicable methods for quality control and calibration. The reliability of quantitative proteomics is tightly linked to the reproducibility and stability of the analytical platforms, which are typically multicomponent (e.g. sample preparation, multistep separations, and mass spectrometry) with individual components contributing unequally to the overall system reproducibility. Variations in quantitative accuracy are thus inevitable, and quality control and calibration become essential for the assessment of the quality of the analyses themselves. Toward this end, the use of internal standards cannot only assist in the detection and removal of outlier data acquired by an irreproducible system (quality control) but can also be used for detection of changes in instruments for their subsequent performance and calibration. Here we introduce a set of halogenated peptides as internal standards. The peptides are custom designed to have properties suitable for various quality control assessments, data calibration, and normalization processes. The unique isotope distribution of halogenated peptides makes their mass spectral detection easy and unambiguous when spiked into complex peptide mixtures. In addition, they were designed to elute sequentially over an entire aqueous to organic LC gradient and to have m/z values within the commonly scanned mass range (300-1800 Da). In a series of experiments in which these peptides were spiked into an enriched N-glycosite peptide fraction (i.e. from formerly N-glycosylated intact proteins in their deglycosylated form) isolated from human plasma, we show the utility and performance of these halogenated peptides for sample preparation and LC injection quality control as well as for retention time and mass calibration. Further use of the peptides for signal intensity normalization and retention time synchronization for selected reaction monitoring experiments is also demonstrated. Molecular & Cellular Proteomics 8: 1934-1946, 2009.
引用
收藏
页码:1934 / 1946
页数:13
相关论文
共 28 条
[21]   An Integrated, Directed Mass Spectrometric Approach for In-depth Characterization of Complex Peptide Mixtures [J].
Schmidt, Alexander ;
Gehlenborg, Nils ;
Bodenmiller, Bernd ;
Mueller, Lukas N. ;
Campbell, Dave ;
Mueller, Markus ;
Aebersold, Ruedi ;
Domon, Bruno .
MOLECULAR & CELLULAR PROTEOMICS, 2008, 7 (11) :2138-2150
[22]   Quantitative proteome analysis using isotope-coded affinity tags and mass spectrometry [J].
Shiio, Yuzuru ;
Aebersold, Ruedi .
NATURE PROTOCOLS, 2006, 1 (01) :139-145
[23]   High sensitivity detection of plasma proteins by multiple reaction monitoring of N-glycosites [J].
Stahl-Zeng, Jianru ;
Lange, Vinzenz ;
Ossola, Reto ;
Eckhardt, Katrin ;
Krek, Wilhelm ;
Aebersold, Ruedi ;
Domon, Bruno .
MOLECULAR & CELLULAR PROTEOMICS, 2007, 6 (10) :1809-1817
[24]   Pseudo internal standard approach for label-free quantitative proteomics [J].
Tabata, Tsuyoshi ;
Sato, Toshitaka ;
Kuromitsu, Junro ;
Oda, Yoshiya .
ANALYTICAL CHEMISTRY, 2007, 79 (22) :8440-8445
[25]   THE BEHAVIOR OF PEPTIDES ON REVERSE-PHASE SUPPORTS DURING HIGH-PRESSURE LIQUID-CHROMATOGRAPHY [J].
WILSON, KJ ;
HONEGGER, A ;
STOTZEL, RP ;
HUGHES, GJ .
BIOCHEMICAL JOURNAL, 1981, 199 (01) :31-41
[26]   Mass defect profiles of biological matrices and the general applicability of mass defect filtering for metabolite detection [J].
Zhang, Haiying ;
Zhu, Mingshe ;
Ray, Kenneth L. ;
Ma, Li ;
Zhang, Donglu .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2008, 22 (13) :2082-2088
[27]  
Zhang Hui, 2006, V328, P177
[28]   Isolation of N-linked glycopeptides from plasma [J].
Zhou, Yong ;
Aebersold, Ruedi ;
Zhang, Hui .
ANALYTICAL CHEMISTRY, 2007, 79 (15) :5826-5837