Simplified and Efficient Quantification of Low-abundance Proteins at Very High Multiplex via Targeted Mass Spectrometry*

被引:58
作者
Burgess, Michael W. [1 ]
Keshishian, Hasmik [1 ]
Mani, D. R. [1 ]
Gillette, Michael A. [1 ,2 ]
Carr, Steven A. [1 ]
机构
[1] Broad Inst MIT & Harvard, Cambridge Ctr 7, Cambridge, MA 02142 USA
[2] Massachusetts Gen Hosp, Boston, MA 02114 USA
基金
美国国家卫生研究院;
关键词
PEPTIDE IMMUNOAFFINITY ENRICHMENT; KINETIC PERFORMANCE; PEAK-CAPACITY; PLASMA; VERIFICATION; BIOMARKERS; PIPELINE; ASSAYS; SIZE;
D O I
10.1074/mcp.M113.034660
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Liquid chromatography-multiple reaction monitoring mass spectrometry (LC-MRM-MS) of plasma that has been depleted of abundant proteins and fractionated at the peptide level into six to eight fractions is a proven method for quantifying proteins present at low nanogram-per-milliliter levels. A drawback of fraction-MRM is the increased analysis time due to the generation of multiple fractions per biological sample. We now report that the use of heated, long, fused silica columns (> 30 cm) packed with 1.9 mu m of packing material can reduce or eliminate the need for fractionation prior to LC-MRM-MS without a significant loss of sensitivity or precision relative to fraction-MRM. We empirically determined the optimal column length, temperature, gradient duration, and sample load for such assays and used these conditions to study detection sensitivity and assay precision. In addition to increased peak capacity, longer columns packed with smaller beads tolerated a 4- to 6-fold increase in analyte load without a loss of robustness or reproducibility. The longer columns also provided a 4-fold improvement in median limit-of-quantitation values with increased assay precision relative to the standard 12 cm columns packed with 3 mu m material. Overall, the optimized chromatography provided an approximately 3-fold increase in analysis throughput with excellent robustness and less than a 2-fold reduction in quantitative sensitivity relative to fraction-MRM. The value of the system for increased multiplexing was demonstrated by the ability to configure an 800-plex MRM-MS assay, run in a single analysis, comprising 2400 transitions with retention time scheduling to monitor 400 unlabeled and heavy labeled peptide pairs.
引用
收藏
页码:1137 / 1149
页数:13
相关论文
共 23 条
[1]   Automated Detection of Inaccurate and Imprecise Transitions in Peptide Quantification by Multiple Reaction Monitoring Mass Spectrometry [J].
Abbatiello, Susan E. ;
Mani, D. R. ;
Keshishian, Hasmik ;
Carr, Steven A. .
CLINICAL CHEMISTRY, 2010, 56 (02) :291-305
[2]   A pipeline that integrates the discovery and verification of plasma protein biomarkers reveals candidate markers for cardiovascular disease [J].
Addona, Terri A. ;
Shi, Xu ;
Keshishian, Hasmik ;
Mani, D. R. ;
Burgess, Michael ;
Gillette, Michael A. ;
Clauser, Karl R. ;
Shen, Dongxiao ;
Lewis, Gregory D. ;
Farrell, Laurie A. ;
Fifer, Michael A. ;
Sabatine, Marc S. ;
Gerszten, Robert E. ;
Carr, Steven A. .
NATURE BIOTECHNOLOGY, 2011, 29 (07) :635-U119
[3]   The kinetic plot method applied to gradient chromatography: Theoretical framework and experimental validation [J].
Broeckhoven, K. ;
Cabooter, D. ;
Lynen, F. ;
Sandra, P. ;
Desmet, G. .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (17) :2787-2795
[4]   Geometry-independent plate height representation methods for the direct comparison of the kinetic performance of LC supports with a different size or morphology [J].
Desmet, G ;
Clicq, D ;
Gzil, P .
ANALYTICAL CHEMISTRY, 2005, 77 (13) :4058-4070
[5]   Multiplexed MS/MS for improved data-independent acquisition [J].
Egertson, Jarrett D. ;
Kuehn, Andreas ;
Merrihew, Gennifer E. ;
Bateman, Nicholas W. ;
MacLean, Brendan X. ;
Ting, Ying S. ;
Canterbury, Jesse D. ;
Marsh, Donald M. ;
Kellmann, Markus ;
Zabrouskov, Vlad ;
Wu, Christine C. ;
MacCoss, Michael J. .
NATURE METHODS, 2013, 10 (08) :744-+
[6]   Implications of column peak capacity on the separation of complex peptide mixtures in single- and two-dimensional high-performance liquid chromatography [J].
Gilar, M ;
Daly, AE ;
Kele, M ;
Neue, UD ;
Gebler, JC .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1061 (02) :183-192
[7]   METHOD OF THE YEAR Quantitative analysis of peptides and proteins in biomedicine by targeted mass spectrometry [J].
Gillette, Michael A. ;
Carr, Steven A. .
NATURE METHODS, 2013, 10 (01) :28-34
[8]   Effects of Column and Gradient Lengths on Peak Capacity and Peptide Identification in Nanoflow LC-MS/MS of Complex Proteomic Samples [J].
Hsieh, Edward J. ;
Bereman, Michael S. ;
Durand, Stanley ;
Valaskovic, Gary A. ;
MacCoss, Michael J. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2013, 24 (01) :148-153
[9]   Quantitative, multiplexed assays for low abundance proteins in plasma by targeted mass spectrometry and stable isotope dilution [J].
Keshishian, Hasmik ;
Addona, Terri ;
Burgess, Michael ;
Kuhn, Eric ;
Carr, Steven A. .
MOLECULAR & CELLULAR PROTEOMICS, 2007, 6 (12) :2212-2229
[10]   Quantification of Cardiovascular Biomarkers in Patient Plasma by Targeted Mass Spectrometry and Stable Isotope Dilution [J].
Keshishian, Hasmik ;
Addona, Terri ;
Burgess, Michael ;
Mani, D. R. ;
Shi, Xu ;
Kuhn, Eric ;
Sabatine, Marc S. ;
Gerszten, Robert E. ;
Carr, Steven A. .
MOLECULAR & CELLULAR PROTEOMICS, 2009, 8 (10) :2339-2349