Doping control analysis in human urine by liquid chromatography-electrospray ionization ion trap mass spectrometry for the Olympic Games Athens 2004: Determination of corticosteroids and quantification of ephedrines, salbutamol and morphine

被引:68
作者
Spyridaki, M. -H.
Kiousi, P.
Vonaparti, A.
Valavani, P.
Zonaras, V.
Zahariou, M.
Sianos, E.
Tsoupras, G.
Georgakopoulos, C.
机构
[1] Olymp Athlet Ctr Athens Spiros Louis, Athens Doping Control Lab, Athens 15123, Greece
[2] Agilent Technol Europe BV, Meyrin Branch, CH-1217 Geneva, Switzerland
关键词
liquid chromatography-electrospray ionization ion trap mass spectrometry; antidoping; corticosteroids; ephedrines; salbutamol; morphine;
D O I
10.1016/j.aca.2006.04.042
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
A new liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS) (n) ion trap method for the determination of corticosteroids in urine has been developed and validated. Some anabolic agents, such as epitrenbolone, trenbolone, 2-hydroxymethylformebolone, tetrahydrogestrinone, gestrinone and formoterol were included in the LC-ESI-MS method. Matrix interference, specificity, identification capability, carry over and robustness were estimated as validation parameters. Recoveries ranged from 74 to 113% at the minimum required performance limit (MRPL), which is 30 ng mL(-1) for corticosteroids and 10 ng mL(-1) for anabolic agents. Methods for the confirmation and quantification of norpseudoephedrine, ephedrine, methylephedrine, salbutamol, morphine and morphine glucuronide were also developed and validated and in order to minimize analysis time, direct urine injection was used. These methods proved to be specific, accurate and precise across a calibration range for each substance since matrix interference, specificity, carry over, within and between run precision, limit of detection, limit of quantification, intermediate precision and uncertainty were estimated. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:242 / 249
页数:8
相关论文
共 17 条
[1]
Analytical methodology for enantiomers of salbutamol in human urine for application in doping control [J].
Bergés, R ;
Segura, J ;
de la Torre, X ;
Ventura, R .
JOURNAL OF CHROMATOGRAPHY B, 1999, 723 (1-2) :173-184
[2]
Analysis of corticosteroids in hair by Liquid chromatography-electrospray ionization mass spectrometry [J].
Bévalot, F ;
Gaillard, Y ;
Lhermitte, MA ;
Pépin, G .
JOURNAL OF CHROMATOGRAPHY B, 2000, 740 (02) :227-236
[3]
DETERMINATION OF DEXAMETHASONE IN URINE AND FECES OF TREATED CATTLE WITH NEGATIVE CHEMICAL-IONIZATION - MASS-SPECTROMETRY [J].
COURTHEYN, D ;
VERCAMMEN, J ;
DEBRABANDER, H ;
VANDENREYT, I ;
BATJOENS, P ;
VANOOSTHUYZE, K ;
VANPETEGHEM, C .
ANALYST, 1994, 119 (12) :2557-2564
[4]
CUMMINSKEY J, 2001, CLUCOCORTICOIDS N DO
[5]
Screening for anabolic steroids in doping analysis by liquid chromatography/electrospray ion trap mass spectrometry [J].
Deventer, K. ;
Van Eenoo, P. ;
Delbeke, F. T. .
BIOMEDICAL CHROMATOGRAPHY, 2006, 20 (05) :429-433
[6]
Method for confirmation of synthetic corticosteroids in doping urine samples by liquid chromatography-electrospray ionisation mass spectrometry [J].
Fluri, K ;
Rivier, L ;
Dienes-Nagy, A ;
You, CH ;
Maître, A ;
Schweizer, C ;
Saugy, M ;
Mangin, P .
JOURNAL OF CHROMATOGRAPHY A, 2001, 926 (01) :87-95
[7]
FRAGAKAKI AG, IN PRESS TECHNOVATIO
[8]
Gay ML, 2001, J AOAC INT, V84, P761
[9]
LC-ESI-MS/MS analysis for the quantification of morphine, codeine, morphine-3-β-D-glucuronide, morphine-6-β-D-glucuronide, and codeine-6-β-D-glucuronide in human urine [J].
Murphy, CM ;
Huestis, MA .
JOURNAL OF MASS SPECTROMETRY, 2005, 40 (11) :1412-1416
[10]
Development of a coupled-column liquid chromatographic tandem mass spectrometric method for the direct determination of betamethasone in urine [J].
Polettini, A ;
Bouland, GM ;
Montagna, M .
JOURNAL OF CHROMATOGRAPHY B, 1998, 713 (02) :339-352