Rapid determination of Pu isotopes and atom ratios in small amounts of environmental samples by an on-line sample pre-treatment system and isotope dilution high resolution inductively coupled plasma mass spectrometry

被引:95
作者
Kim, CS [1 ]
Kim, CK
Lee, JI
Lee, KJ
机构
[1] Korea Inst Nucl Safety, Dept Environm Radioact Assessment, Taejon 305338, South Korea
[2] Korea Adv Inst Sci & Technol, Dept Nucl Engn, Seoul 131, South Korea
关键词
D O I
10.1039/a907739a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Isotope dilution (ID) high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) combined with an on-line sample pre-treatment method was applied to the trace determination of Pu-239, Pu-240 and Pu-240/Pu-239 ratios in small amounts of environmental samples. To reduce the interference effect of U-238, a microconcentric nebulizer, MCN-6000(R), was used as a sample introduction method, which showed a 5-fold lower UH+/U+ ratio than the conventional pneumatic nebulizer. U-238 separation and preconcentration of Pu were performed sequentially on two extraction resins, Sr-Spec(R) and TEVA-Spec(R), which were sequentially combined in PrepLab(TM), an integrated liquid handing system. By reducing the final sample volume to 2.4 ml, injecting it into the HR-ICP-MS system and employing the MCN-6000, the analysis of Pu isotopes is feasible in 1 g of soil and sediment having the environmental level of Pu. The detection limits for Pu-239, Pu-240 and Pu-242 by this method were about 4 fg ml(-1) (9.2 mu Bq ml(-1)), 3 fg ml(-1) (25 mu Bq ml(-1)) and 6 fg ml(-1) (0.87 mu Bq ml(-1)), respectively. These represent total amounts of 9.6, 7.2 and 14 fg for Pu-239, Pu-240 and Pu-242 in a final sample volume. After digestion of the sample, the U-238 elimination and Pu preconcentration procedures were fully automated. Sample preparation is therefore far simpler and the full sample analysis process can be achieved within about 5 h. The analytical reliability was confirmed using several certified or standard reference materials (NIST SRM-4350b, IAEA-6, IAEA-300, IAEA-367, IAEA-368, IAEA-375).
引用
收藏
页码:247 / 255
页数:9
相关论文
共 30 条
[1]   Determination of long-lived radionuclides by inductively coupled plasma quadrupole mass spectrometry using different nebulizers [J].
Becker, JS ;
Soman, RS ;
Sutton, KL ;
Caruso, JA ;
Dietze, HJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (06) :933-937
[2]  
CHIAPPINI R, 1999, J ANAL ATOM SPECTROM, V14, P933
[3]   ENVIRONMENTAL-STUDY OF FALLOUT PLUTONIUM IN SOILS FROM THE PIEMONTE REGION (NORTHWEST ITALY) [J].
CIGNA, AA ;
ROSSI, LC ;
SGORBINI, S ;
ZURLINI, G .
JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 1987, 5 (01) :71-81
[4]   HYDRIDE INTERFERENCE ON THE DETERMINATION OF MINOR ACTINIDE ISOTOPES BY INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY [J].
CRAIN, JS ;
ALVARADO, J .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (11) :1223-1227
[5]  
*EICHR IND, 1996, EXTR CHROM MAT RAP S
[6]   Determination of plutonium in seawater using co-precipitation and inductively coupled plasma mass spectrometry with ultrasonic nebulisation [J].
Eroglu, AE ;
McLeod, CW ;
Leonard, KS ;
McCubbin, D .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (6-8) :1221-1233
[7]   Reduction of water loading effects in inductively coupled plasma mass spectrometry by a Nafion membrane dryer device [J].
Fitzgerald, N ;
Tyson, JF ;
Leighty, DA .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (01) :13-16
[8]   Procedures to define Pu isotopic ratios characterizing a contaminated area in Palomares (Spain) [J].
Gasco, CP ;
Anton, MP ;
Espinosa, A ;
Aragon, A ;
Alvarez, A ;
Navarro, N ;
Garcia-Torano, E .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1997, 222 (1-2) :81-86
[9]   GLOBAL INVENTORY AND DISTRIBUTION OF FALLOUT PLUTONIUM [J].
HARDY, EP ;
KREY, PW ;
VOLCHOK, HL .
NATURE, 1973, 241 (5390) :444-445
[10]   INVENTORY OF PU-238 AND PU-239,PU-240 IN THE SOIL OF CZECHOSLOVAKIA IN 1990 [J].
HOLGYE, Z ;
FILGAS, R .
JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 1995, 27 (02) :181-189