Effects of pollution from personal computers on perceived air quality, SBS symptoms and productivity in offices

被引:123
作者
Bakó-Biró, Z
Wargocki, P
Weschler, CJ
Fanger, PO
机构
[1] Tech Univ Denmark, Int Ctr Indoor Environm & Energy, DK-2800 Lyngby, Denmark
[2] Budapest Univ Technol & Econ, Dept Bldg Serv Engn 1, Budapest, Hungary
[3] Univ Med & Dent New Jersey, Robert Wood Johnson Med Sch, Dept Environm & Community Med, Piscataway, NJ 08854 USA
关键词
personal computers; perceived air quality; productivity; sensory pollution; SBS symptoms; chemical emissions;
D O I
10.1111/j.1600-0668.2004.00218.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In groups of six, 30 female subjects were exposed for 4.8 h in a low-polluting office to each of two conditions-the presence or absence of 3-month-old personal computers (PCs). These PCs were placed behind a screen so that they were not visible to the subjects. Throughout the exposure the outdoor air supply was maintained at 10 1/s per person. Under each of the two conditions the subjects performed simulated office work using old low-polluting PCs. They also evaluated the air quality and reported Sick Building Syndrome (SBS) symptoms. The PCs were found to be strong indoor pollution sources, even after they had been in service for 3 months. The sensory pollution load of each PC was 3.4 olf, more than three times the pollution of a standard person. The presence of PCs increased the percentage of people dissatisfied with the perceived air quality from 13 to 41% and increased by 9% the time required for text processing. Chemical analyses were performed to determine the pollutants emitted by the PCs. The most significant chemicals detected included phenol, toluene, 2-ethylhexanol, formaldehyde, and styrene. The identified compounds were, however, insufficient in concentration and kind to explain the observed adverse effects. This suggests that chemicals other than those detected, so-called 'stealth chemicals', may contribute to the negative effects.
引用
收藏
页码:178 / 187
页数:10
相关论文
共 43 条
[21]   Effectiveness of a VDT ergonomics training program [J].
Lewis, RJ ;
Fogleman, M ;
Deeb, J ;
Crandall, E ;
Agopsowicz, D .
INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS, 2001, 27 (02) :119-131
[22]   The genotoxic potential of electric and magnetic fields: an update [J].
McCann, J ;
Dietrich, F ;
Rafferty, C .
MUTATION RESEARCH-REVIEWS IN MUTATION RESEARCH, 1998, 411 (01) :45-86
[23]  
*NIOSH, 2002, PUBL DHHS
[24]  
PEJTERSEN J, 1999, P IND AIR 99 ED 8 IN, V2, P160
[25]  
REYNOLDS M, 2002, BILLIONTH PC SHIPS G
[26]  
SALTHAMMER T, 2002, P 9 INT C IND AIR CL, V2, P213
[27]   Flame retardants in indoor air at an electronics recycling plant and at other work environments [J].
Sjödin, A ;
Carlsson, H ;
Thuresson, K ;
Sjölin, S ;
Bergman, Å ;
Östman, C .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2001, 35 (03) :448-454
[28]  
Skyberg K, 1997, ADV HUM FACT ERGON, V21, P655
[29]   SICK BUILDING SYNDROME (SBS) IN OFFICE WORKERS AND FACIAL SKIN SYMPTOMS AMONG VDT-WORKERS IN RELATION TO BUILDING AND ROOM CHARACTERISTICS - 2 CASE-REFERENT STUDIES [J].
SUNDELL, J ;
LINDVALL, T ;
STENBERG, B ;
WALL, S .
INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1994, 4 (02) :83-94
[30]   The impact of keyboard design on comfort and productivity in a text-entry task [J].
Swanson, NG ;
Galinsky, TL ;
Cole, LL ;
Pan, CS ;
Sauter, SL .
APPLIED ERGONOMICS, 1997, 28 (01) :9-16