A new design of a diffused laser light optically pumped small cesium beam frequency standard

被引:13
作者
Chen, JB [1 ]
Wang, FZ [1 ]
Wang, YQ [1 ]
Yang, DH [1 ]
机构
[1] Peking Univ, Dept Elect, Beijing 100871, Peoples R China
关键词
D O I
10.1109/58.827435
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A new set-up of a small Cs clock has been successfully experimentally tested. The short-term stability (2 x 10(-11)/root tau) and the long-term stability (3.5 x 10(-13) for a day sample time) have been measured. Only one laser is needed without any frequency shift device. The light frequency shift caused by diffuse light was calculated and measured.
引用
收藏
页码:457 / 460
页数:4
相关论文
共 9 条
[1]   SLOWING OF RB-85 ATOMS WITH ISOTROPIC LIGHT [J].
BATELAAN, H ;
PADUA, S ;
YANG, DH ;
XIE, C ;
GUPTA, R ;
METCALF, H .
PHYSICAL REVIEW A, 1994, 49 (04) :2780-2784
[2]   Frequency shifts in cesium beam clocks induced by microwave leakages [J].
Boussert, B ;
Theobald, G ;
Cerez, P ;
de Clercq, E .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (03) :728-738
[3]  
HAGIMOTO K, 1998, CPEM 98 WASH DC, P14
[4]  
LEE WD, P 1997 IEEE INT FREQ, P249
[5]  
MAKDISSI A, CPEM 98 WASH DC, P16
[6]  
YANG D, P 1997 IEEE INT FREQ, P228
[7]   PRELIMINARY-RESULTS OF AN OPTICALLY PUMPED CESIUM BEAM FREQUENCY STANDARD AT PEKING UNIVERSITY [J].
YANG, DH ;
WANG, YQ .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1991, 40 (06) :1000-1002
[8]   EXPERIMENT ON OPTICALLY PUMPED CESIUM BEAM FREQUENCY STANDARD WITH SHARP ANGLE INCIDENCE PROBING LASER-BEAM [J].
YANG, DH ;
LI, EX ;
CHEN, LM ;
HUANG, BY ;
WANG, YQ .
OPTICS COMMUNICATIONS, 1991, 84 (5-6) :275-278
[9]  
YANG DH, P 1996 IEEE INT FREQ, P1051