Improving the biomechanical properties of the T-fix using oblique direction: in vitro study on bovine menisci

被引:17
作者
Karaoglu, S [1 ]
Duygulu, F [1 ]
Inan, M [1 ]
Baktir, A [1 ]
机构
[1] Erciyes Univ, Sch Med, Dept Orthoped Surg & Traumatol, TR-38039 Kayseri, Turkey
关键词
meniscus repair; T-fix; pullout-strength;
D O I
10.1007/s00167-002-0281-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This study compared pull-out strengths of the T-fix device versus horizontal suture toward improving T-fix biomechanical properties. Twenty bovine medial menisci were used for this study. Four groups were tested and mean tearing stress were obtained. In group 1 a standard T-fix suture was performed (50.2+/-4.2 N); in group 2 horizontal mattress sutures were placed in the meniscus using 2-0 vicryl (54.6+/-4.2 N); in group 3 three T-fix suture anchors were placed: the central suture a double suture anchor and those on either side single suture anchors, resulting in two horizontal sutures (61.8+/-3.8 N); in group 4 we modified the technique used in group 3. The double suture anchor was placed the incision, at a 30degrees angle oblique to the horizontal (71.0+/-5.9 N). There was a statistically significant difference between groups 3 and 4 but not between groups 1 and 2. In conclusion: Using it T-fix suture anchor in the standard technique has similar biomechanical properties to the horizontal mattress suture. To improve the tensile properties of the T-fix suture a double T-fix suture anchor should be used obliquely to the other two single T-fix sutures on either side.
引用
收藏
页码:198 / 201
页数:4
相关论文
共 18 条
[1]
Failure strength of a new meniscus arrow repair technique: Biomechanical comparison with horizontal suture [J].
AlbrechtOlsen, P ;
Lind, T ;
Kristensen, G ;
Falkenberg, B .
ARTHROSCOPY, 1997, 13 (02) :183-187
[2]
LATE DEGENERATIVE CHANGES AFTER MENISCECTOMY - FACTORS AFFECTING THE KNEE AFTER OPERATION [J].
ALLEN, PR ;
DENHAM, RA ;
SWAN, AV .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1984, 66 (05) :666-671
[3]
Tensile fixation strengths of absorbable meniscal repair devices as a function of hydrolysis time - An in vitro experimental study [J].
Arnoczky, SP ;
Lavagnino, M .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2001, 29 (02) :118-123
[4]
Strength of different meniscus suturing techniques [J].
Aşik M. ;
Şener N. ;
Akpinar S. ;
Durmaz H. ;
Göksan A. .
Knee Surgery, Sports Traumatology, Arthroscopy, 1997, 5 (2) :80-83
[5]
Barber F A, 1987, Arthroscopy, V3, P25, DOI 10.1016/S0749-8063(87)80006-3
[6]
Meniscal repair devices [J].
Barber, FA ;
Herbert, MA .
ARTHROSCOPY, 2000, 16 (06) :613-618
[7]
ACCELERATED REHABILITATION FOR MENISCUS REPAIRS [J].
BARBER, FA .
ARTHROSCOPY, 1994, 10 (02) :206-210
[8]
Barrett G R, 1996, Am J Knee Surg, V9, P151
[9]
T-FIX ENDOSCOPIC MENISCAL REPAIR - TECHNIQUE AND APPROACH TO DIFFERENT TYPES OF TEARS [J].
BARRETT, GR ;
RICHARDSON, K ;
KOENIG, V .
ARTHROSCOPY, 1995, 11 (02) :245-251
[10]
Preliminary results of the T-fix endoscopic meniscus repair technique in an anterior cruciate ligament reconstruction population [J].
Barrett, GR ;
Treacy, SH ;
Ruff, CG .
ARTHROSCOPY, 1997, 13 (02) :218-223