Plasticizer contamination from vacuum system o-rings in a quadrupole ion trap mass spectrometer

被引:30
作者
Verge, KM [1 ]
Agnes, GR [1 ]
机构
[1] Simon Fraser Univ, Dept Chem, Burnaby, BC V5A 1S6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
D O I
10.1016/S1044-0305(02)00386-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The outgassing of plasticizers from Buna-N and Viton o-rings under vacuum lead to undesired ion-molecule chemistry in an Electrospray Quadrupole Ion Trap Mass Spectrometer. In experiments with the helium bath gas pressure >1.2 mTorr, or whenever analyte ions were stored for >100 ms, extensive loss of analyte ions by proton transfer or adduction with o-ring plasticizers bis(2-ethylhexyl) phthalate and bis(2-ethylhexyl) adipate occurred. A temporary solution to this contamination problem was found to be overnight refluxing in hexane of all the o-rings in the vacuum system. This procedure alleviated this plasticizer contamination for similar to100 hours of operation. These results, and those that lead to identification of the contamination as plasticizers outgassing from o-rings are described. (C) 2002 American Society for Mass Spectrometry.
引用
收藏
页码:901 / 905
页数:5
相关论文
共 27 条
[1]  
Aebi B, 1996, RAPID COMMUN MASS SP, V10, P947, DOI 10.1002/(SICI)1097-0231(19960610)10:8<947::AID-RCM609>3.0.CO
[2]  
2-B
[3]   Estimation of the environmental contamination by phthalic acid esters leaching from household wastes [J].
Bauer, MJ ;
Herrmann, R .
SCIENCE OF THE TOTAL ENVIRONMENT, 1997, 208 (1-2) :49-57
[4]   Poly(ethylene glycol) doubly and singly cationized by different alkali metal ions: Relative cation affinities and cation-dependent resolution in a quadrupole ion trap mass spectrometer [J].
Bogan, MJ ;
Agnes, GR .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2002, 13 (02) :177-186
[5]   TRACE IMPURITIES IN SOLVENTS COMMONLY USED FOR GAS-CHROMATOGRAPHIC ANALYSIS OF ENVIRONMENTAL-SAMPLES [J].
BOWERS, WD ;
PARSONS, ML ;
CLEMENT, RE ;
EICEMAN, GA ;
KARASEK, FW .
JOURNAL OF CHROMATOGRAPHY, 1981, 206 (02) :279-288
[6]   A combined linear ion trap time-of-flight system with improved performance and MSn capabilities [J].
Collings, BA ;
Campbell, JM ;
Mao, DM ;
Douglas, DJ .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (19) :1777-1795
[7]  
Ende M., 1982, MASS SPECTROM REV, P33, DOI DOI 10.1002/MAS.1280010105
[8]  
FURTMANN K, 1995, ANAL METHOD INSTRUM, V2, P254
[9]  
Hemberger P. H., 1989, RAPID COMMUN MASS SP, V3, P50
[10]   A COMPARISON OF DIFFERENT WAYS OF SAMPLE PREPARATION FOR THE DETERMINATION OF PHTHALIC-ACID ESTERS IN WATER AND PLANT MATRICES [J].
HOLADOVA, K ;
HAJSLOVA, J .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1995, 59 (01) :43-57