Identification of cellular sections with imaging mass spectrometry following freeze fracture

被引:74
作者
Roddy, TP [1 ]
Cannon, DM [1 ]
Ostrowski, SG [1 ]
Winograd, N [1 ]
Ewing, AG [1 ]
机构
[1] Penn State Univ, Dept Chem, Davey Lab 152, University Pk, PA 16802 USA
关键词
D O I
10.1021/ac025574w
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Freeze-fracture techniques have been used to maintain chemical heterogeneity of frozen-hydrated mammalian cells for static TOF-SIMS imaging. The effects the fracture plane has on scanning electron microscopy and dynamic SIMS images of cells have been studied, but the implications this preparation method has on static SIMS have not been addressed to date. Interestingly, the chemical specificity and surface sensitivity of TOF-SIMS have allowed the identification of unique sections of rat pheochromocytoma cells exposed to the sample surface during freeze fracture. Using the extensive chemical information of the fractured surface, cellular sections have been determined using TOF-SIMS images of water, sodium, potassium, hydrocarbons, phosphocholine, and DiI, a fluorescent dye that remains in the outer leaflet of the cell membrane. Higher amounts of potassium have been imaged inside a cell versus the surrounding matrix in a cross-fractured cell. In other fractures exposing the cell membrane, phosphocholine and DiI have been imaged on the outer leaflet of the cell membrane, while phosphocholine alone has been imaged on the inner leaflet. In this paper, we discuss how imaging mass spectrometry is used to uniquely distinguish three possible sections of cells obtained during freeze fracture. The identification of these sections is important in choosing cells with a region of interest, like the cell membrane, exposed to the surface for a more thorough investigation with imaging static TOF-SIMS.
引用
收藏
页码:4020 / 4026
页数:7
相关论文
共 27 条
[11]  
Echlin P., 1992, LOW TEMPERATURE MICR
[12]  
Galle P, 1996, CELL MOL BIOL, V42, P325
[13]  
GREENE LA, 1987, METHOD ENZYMOL, V147, P207
[14]  
LeviSetti R, 1996, CELL MOL BIOL, V42, P301
[15]   HIGH MASS RESOLUTION SECONDARY ION MASS-SPECTROMETRY VIA SIMULTANEOUS DETECTION WITH A CHARGE-COUPLED DEVICE [J].
MANTUS, DS ;
VALASKOVIC, GA ;
MORRISON, GH .
ANALYTICAL CHEMISTRY, 1991, 63 (08) :788-792
[16]   Secondary ion images of the rodent brain [J].
McCandlish, CA ;
McMahon, JM ;
Todd, PJ .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2000, 11 (03) :191-199
[17]  
McMahon JM, 1996, RAPID COMMUN MASS SP, V10, P335, DOI 10.1002/(SICI)1097-0231(199602)10:3<335::AID-RCM516>3.3.CO
[18]  
2-N
[19]  
Pacholski ML, 1998, RAPID COMMUN MASS SP, V12, P1232, DOI 10.1002/(SICI)1097-0231(19980930)12:18<1232::AID-RCM319>3.3.CO
[20]  
2-7