摘要
We have measured the intensity profile and transmission of x rays focused by a series of biconcave spherical unit lenses fabricated from beryllium. The use of beryllium extends the range of operation of compound refractive lenses, improving transmission, aperture size, and gain. The compound refractive lens was composed of 160 biconcave unit lenses, each with a radius of curvature of 1.9 mm. Two-dimensional focusing with a gain of 1.5 was obtained at 6.5 keV with a focal length of 93 cm. The effective aperture of the compound refractive lens was measured as 600 mum, with 9% peak transmission. (C) 2002 Optical Society of America.
引用
收藏
页码:778 / 780
页数:3
相关论文
共 17 条
[11]   Two-dimensional x-ray focusing from compound lenses made of plastic [J].
Piestrup, MA ;
Cremer, JT ;
Beguiristain, HR ;
Gary, CK ;
Pantell, RH .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (12) :4375-4379
[12]  
PIESTRUP MA, 2001, Patent No. 6269145
[13]   Potential of a beryllium x-ray lens [J].
Smither, RK ;
Khounsary, AM ;
Xu, SL .
HIGH HEAT FLUX AND SYNCHROTRON RADIATION BEAMLINES, 1997, 3151 :150-163
[14]   Refractive lenses for high energy X-ray focusing [J].
Snigirev, A ;
Filseth, B ;
Elleaume, P ;
Klocke, T ;
Kohn, V ;
Lengeler, B ;
Snigireva, I ;
Souvorov, A ;
Tummler, J .
HIGH HEAT FLUX AND SYNCHROTRON RADIATION BEAMLINES, 1997, 3151 :164-170
[15]   A compound refractive lens for focusing high-energy X-rays [J].
Snigirev, A ;
Kohn, V ;
Snigireva, I ;
Lengeler, B .
NATURE, 1996, 384 (6604) :49-51
[16]  
Tomie T., 1994, Japanese Patent, Patent No. [6-045288, 6045288]
[17]   FRESNEL AND REFRACTIVE LENSES FOR X-RAYS [J].
YANG, BX .