An ultrasound-assisted approach facilitates spinal anesthesia for total joint arthroplasty

被引:64
作者
Chin, Ki Jinn [1 ]
Perlas, Anahi [1 ]
Singh, Mandeep [1 ]
Arzola, Cristian [2 ]
Prasad, Arun [1 ]
Chan, Vincent [1 ]
Brull, Richard [1 ]
机构
[1] Toronto Western Hosp, Dept Anesthesia, Toronto, ON M5T 2S8, Canada
[2] Mt Sinai Hosp, Dept Anesthesia, Toronto, ON M5G 1X5, Canada
来源
CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE | 2009年 / 56卷 / 09期
关键词
OBSTETRIC EPIDURAL-ANESTHESIA; LUMBAR INTERSPACE; NEURAXIAL BLOCK; LEVEL; DIFFICULT; IDENTIFY; PUNCTURE; SPACE; IDENTIFICATION; LANDMARKS;
D O I
10.1007/s12630-009-9132-8
中图分类号
R614 [麻醉学];
学科分类号
100217 [麻醉学];
摘要
Spinal anesthesia can be challenging in patients undergoing total joint arthroplasty because of poorly palpable surface landmarks and age-related changes in the lumbar spine. We hypothesized that pre-procedural ultrasound imaging would be effective in identifying the lumbar intervertebral spaces and would provide an accurate measure of the depth to the intrathecal space. Fifty patients undergoing elective total joint arthroplasty were recruited in this prospective descriptive study. Using a curved-array 2-5 MHz transducer, the lumbar spine was imaged in two views, i.e., longitudinal parasagittal (LP) and transverse midline (TM). The intervertebral levels were identified by counting upwards from the sacrum. The locations of the interlaminar spaces were identified by visualizing the ligamentum flavum-dura mater complex and the posterior aspect of the vertebral body. The needle insertion point for a midline approach was determined from the ultrasound examination and was marked on the skin of the patient's back. The mean patient age was 67 +/- A 10 yr, and 46% of the patients had a body mass index > 30 kg center dot A m(-2). Surface landmarks were difficult or impossible to palpate in 38% of the patients. The scan quality on the LP and TM views was adequate or better in 100 and 98% of the patients, respectively. Dural puncture was achieved with one needle insertion attempt and within two needle insertion attempts in 84% and 98% of the patients, respectively. The ultrasound-measured depth to the intrathecal space correlated well with the actual needle insertion depth (concordance correlation coefficient = 0.82, accuracy 0.95, precision 0.86), with a tendency to overestimate the depth by just 2.1 +/- A 5.4 mm. Ultrasound imaging of the lumbar spine provides clinically useful information that can facilitate spinal anesthesia in the older orthopedic patient population.
引用
收藏
页码:643 / 650
页数:8
相关论文
共 25 条
[1]
Arzola C, 2006, CAN J ANESTH, V53, P26291
[2]
Arzola C, 2007, CAN J ANAESTH, V54, P620, DOI 10.1007/BF03022955
[3]
Ultrasound using the transverse approach to the lumbar spine provides reliable landmarks for labor epidurals [J].
Arzola, Cristian ;
Davies, Sharon ;
Rofaeel, Ayman ;
Carvalho, Jose C. A. .
ANESTHESIA AND ANALGESIA, 2007, 104 (05) :1188-1192
[4]
Development of a difficulty score for spinal anaesthesia [J].
Atallah, MM ;
Demian, AD ;
Shorrab, AA .
BRITISH JOURNAL OF ANAESTHESIA, 2004, 92 (03) :354-360
[5]
Ability of anaesthetists to identify a marked lumbar interspace [J].
Broadbent, CR ;
Maxwell, WB ;
Ferrie, R ;
Wilson, DJ ;
Gawne-Cain, M ;
Russell, R .
ANAESTHESIA, 2000, 55 (11) :1122-1126
[6]
Carvalho Jose Carlos Almeida, 2008, Anesthesiol Clin, V26, P145, DOI 10.1016/j.anclin.2007.11.007
[7]
Predictors of successful neuraxial block: a prospective study. [J].
de Oliveira, GR ;
Gomes, HP ;
da Fonseca, MHZ ;
Hoffman, JC ;
Pederneiras, SG ;
Garcia, JHS .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2002, 19 (06) :447-451
[8]
An evaluation of ultrasound imaging for identification of lumbar intervertebral level [J].
Furness, G ;
Reilly, MP ;
Kuchi, S .
ANAESTHESIA, 2002, 57 (03) :277-280
[9]
Grau T, 2003, CAN J ANAESTH, V50, P1047, DOI 10.1007/BF03018371
[10]
Efficacy of ultrasound imaging in obstetric epidural anesthesia [J].
Grau, T ;
Leipold, RW ;
Conradi, R ;
Martin, E ;
Motsch, J .
JOURNAL OF CLINICAL ANESTHESIA, 2002, 14 (03) :169-175