An automated biochemical assay for haptoglobin: Prevention of interference from albumin

被引:86
作者
Eckersall, PD
Duthie, S
Safi, S
Moffatt, D
Horadagoda, NU
Doyle, S
Parton, R
Bennett, D
Fitzpatrick, JL
机构
[1] Univ Glasgow, Sch Vet, Dept Vet Med, Clin Biochem Sect, Glasgow G61 1QH, Lanark, Scotland
[2] Univ Glasgow, Sch Vet, Dept Vet Clin Studies, Div Small Anim Clin Studies, Glasgow G61 1QH, Lanark, Scotland
[3] Univ Glasgow, Sch Vet, Dept Vet Clin Studies, Div Farm Anim Clin Studies & Anim Prod, Glasgow G61 1QH, Lanark, Scotland
[4] Univ Glasgow, Inst Biomed & Life Sci, Div Infect & Immun, Glasgow, Lanark, Scotland
[5] Natl Univ Ireland, Dept Biol, Maynooth, Kildare, Ireland
来源
COMPARATIVE HAEMATOLOGY INTERNATIONAL | 1999年 / 9卷 / 03期
关键词
assay; cattle; dog; haemoglobin binding; haptoglobin; rat;
D O I
10.1007/s005800050020
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Measurement of the acute phase serum protein, haptoglobin (Hp), is performed by biochemical methods based on haemoglobin binding, in many veterinary diagnostic laboratories. During attempts to develop a robust biochemical assay for serum Hp it was discovered that serum albumin interfered with the assay system increasing results by as much as 0.28 mg/ml, which could affect interpretation of results especially in species with low normal Hp concentrations. A reagent cocktail (SB-7) was devised which inhibited the interfering effect of albumin. An automated assay for Hp utilising SB-7 was developed for production as a biochemical assay kit and was evaluated for use in veterinary diagnosis. The intra-assay coefficients of variation were of 0.9%, 0.9% and 1.3% for Hp concentrations of 2.0, 1.0 and 0.23 mg/ml, respectively and interassay coefficients of variation of 1.7% and 4.5% for Hp of 2.08 mg/ml and 0.24 mg/ml, respectively. The lower Limit of detection of was 0.02 mg/ml, linearity extended to 8 mg/ml and recovery was 101+/-7% (mean +/- SD). The assay had correlation coefficients (R-2) of 0.96 and 0.90 when compared with immunodiffusion assays of canine Hp and bovine Hp, respectively. Lipaemia and bilirubinaemia caused no interference. Haemolysis did not affect measurement of low levels of Hp, but at serum Hp concentrations of 0.4 and 1.8 mg/ml the apparent Hp concentration was decreased. Elevated concentrations of Hp were measured in cattle with mastitis, dogs with polyarthritis and rats experimentally infected with Bordetella pertussis. The automated assay is precise and has negligible interference from albumin.
引用
收藏
页码:117 / 124
页数:8
相关论文
共 18 条
[1]  
BENESCH RE, 1990, J BIOL CHEM, V265, P14881
[2]  
Eckersall P. D., 1988, Animal clinical biochemistry - the future., P225
[3]  
Eckersall PD, 1999, ADV VET MED-ACAD PR, V41, P643
[4]   ACUTE-PHASE PROTEINS AS MARKERS OF INFLAMMATORY LESIONS [J].
ECKERSALL, PD .
COMPARATIVE HAEMATOLOGY INTERNATIONAL, 1995, 5 (02) :93-97
[5]   BOVINE AND CANINE ACUTE PHASE PROTEINS [J].
ECKERSALL, PD ;
CONNER, JG .
VETERINARY RESEARCH COMMUNICATIONS, 1988, 12 (2-3) :169-178
[6]  
EURELL TE, 1992, CAN J VET RES, V56, P6
[7]   Stability of the heme-globin linkage in alpha beta dimers and isolated chains of human hemoglobin - A study of the heme transfer reaction from the immobilized proteins to albumin [J].
Gattoni, M ;
Boffi, A ;
Sarti, P ;
Chiancone, E .
JOURNAL OF BIOLOGICAL CHEMISTRY, 1996, 271 (17) :10130-10136
[8]   COUGH PRODUCTION, LEUKOCYTOSIS AND SEROLOGY OF RATS INFECTED INTRABRONCHIALLY WITH BORDETELLA-PERTUSSIS [J].
HALL, E ;
PARTON, R ;
WARDLAW, AC .
JOURNAL OF MEDICAL MICROBIOLOGY, 1994, 40 (03) :205-213
[9]  
Harvey J W, 1986, Vet Clin Pathol, V15, P4, DOI 10.1111/j.1939-165X.1986.tb00648.x
[10]   IMMEDIATE RESPONSES IN SERUM TNF-ALPHA AND ACUTE-PHASE PROTEIN CONCENTRATIONS TO INFECTION WITH PASTEURELLA-HAEMOLYTICA A1 IN CALVES [J].
HORADAGODA, A ;
ECKERSALL, PD ;
HODGSON, JC ;
GIBBS, HA ;
MOON, GM .
RESEARCH IN VETERINARY SCIENCE, 1994, 57 (01) :129-132