Improved separation of the 209 polychlorinated biphenyl congeners using comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry

被引:76
作者
Focant, JF [1 ]
Sjödin, A [1 ]
Patterson, DG [1 ]
机构
[1] Ctr Dis Control & Prevent, Natl Ctr Environm Hlth, Div Sci Lab, Organ Analyt Toxicol Branch, Atlanta, GA 30341 USA
关键词
resolution; gas chromatography; comprehensive two-dimensional; polychlorinated biphenyls;
D O I
10.1016/j.chroma.2004.04.003
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The separation of the 209 polychlorinated biphenyl (PCB) congeners has been studied using comprehensive two-dimensional gas chromatography coupled to time-of-flight mass spectrometry (GC x GC-TOFMS). Four column combinations based on thermally stable phases, DB-/HT-8, DB-XLB/HT-8, DB-XLB/BPX-50, and HT-8/BPX-50, have been investigated. The HT-8/13PX-50 set produced the best separation. The distribution of the 100 to 150ms wide peaks was highly structured in the chromatographic space and based on the degree of ortho-substitution within each separated homologue series. A total of 192 congeners were resolved in 146 min (1.3 analyte per min) using this column set. Eight coelutions involved 17 congeners. Among them, seven congeners were present in Aroclors at levels > 1.0wt.% (CBs 33, 47, 48, 95, 97, 163, 187). Except for CBs 47 and 48, none of the major constituents of commercial mixtures were coeluting. CB 138 was well separated from CBs 163 and 164 in the second dimension. For all column sets, CBs 20, 33, and 109 always coeluted with other PCBs. The 12 toxic dioxin-like congeners (CBs 77, 81, 105, 114, 118, 123, 126, 156, 157, 167, 169, 189), and the seven European Union marker PCBs (CBs 28, 52, 101, 118, 138, 153, 180) were separated from any interfering congeners. This was not the case for the other investigated column sets. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:227 / 238
页数:12
相关论文
共 53 条
[1]   ANALYSIS OF POLYCHLORINATED-BIPHENYLS (PCB) BY GLASS-CAPILLARY GAS-CHROMATOGRAPHY - COMPOSITION OF TECHNICAL AROCLOR-PCB AND CLOPHEN-PCB MIXTURES [J].
BALLSCHMITER, K ;
ZELL, M .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1980, 302 (01) :20-31
[2]  
BALLSCHMITER K, 1992, HRC-J HIGH RES CHROM, V15, P260
[3]   ISOMER-SPECIFIC IDENTIFICATION OF PCB CONGENERS IN TECHNICAL MIXTURES AND ENVIRONMENTAL-SAMPLES BY HRGC-ECD AND HRGC-MSD [J].
BALLSCHMITER, K ;
SCHAFER, W ;
BUCHERT, H .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1987, 326 (03) :253-257
[4]  
Bertsch W, 1999, HRC-J HIGH RES CHROM, V22, P647, DOI 10.1002/(SICI)1521-4168(19991201)22:12<647::AID-JHRC647>3.0.CO
[5]  
2-V
[6]   Gas chromatographic methods for oil analysis [J].
Blomberg, J ;
Schoenmakers, PJ ;
Brinkman, UAT .
JOURNAL OF CHROMATOGRAPHY A, 2002, 972 (02) :137-173
[7]   PHYSICAL, SPECTRAL AND CHROMATOGRAPHIC PROPERTIES OF ALL 209 INDIVIDUAL PCB CONGENERS [J].
BOLGAR, M ;
CUNNINGHAM, J ;
COOPER, R ;
KOZLOSKI, R ;
HUBBALL, J ;
MILLER, DP ;
CRONE, T ;
KIMBALL, H ;
JANOOBY, A ;
MILLER, B ;
FAIRLESS, B .
CHEMOSPHERE, 1995, 31 (02) :2687-2705
[8]   Recent developments in the high-resolution gas chromatography of polychlorinated biphenyls [J].
Cochran, JW ;
Frame, GM .
JOURNAL OF CHROMATOGRAPHY A, 1999, 843 (1-2) :323-368
[9]   Fast gas chromatography-time-of-flight mass spectrometry of polychlorinated biphenyls and other environmental contaminants [J].
Cochran, JW .
JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2002, 40 (05) :254-268
[10]   Mass spectrometric detection in narrow-bore (0.10 mm ID) capillary chromatography - Fast, sensitive and selective analysis of polychlorinated biphenyls [J].
Covaci, A ;
Schepens, P .
JOURNAL OF CHROMATOGRAPHY A, 2001, 923 (1-2) :287-293