Determination of acetone in human breath by gas chromatography-mass spectrometry and solid-phase microextraction with on-fiber derivatization

被引:488
作者
Deng, CH
Zhang, J
Yu, XF
Zhang, W
Zhang, XM
机构
[1] Fudan Univ, Dept Chem, Shanghai 200433, Peoples R China
[2] Huadong Hosp, Shanghai 200040, Peoples R China
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2004年 / 810卷 / 02期
关键词
acetone; breath analysis; derivatization; GC;
D O I
10.1016/j.jchromb.2004.08.013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Analysis of breath acetone has been used as a diagnostic tool for diabetes. Due to its nature of volatility and activity, it is very difficult to accurately measure the concentration of acetone in human breath by gas chromatography-mass spectrometry (GC-MS). To overcome this problem, we developed a new method using GC-MS and solid-phase microextraction (SPME) with on-fiber derivatization to determine acetone in human breath. Breath gas from controls and diabetic patients was collected in 3-1 Tedlar bags. 0-2,3,4,5,6-(Pentafluorobenzyl) hydroxylamine hydrochloride (PFBHA) in solution was firstly adsorbed on the SPME fiber of 65 mum polydimethylsiloxane-divinylbenzene (PDMS-DVB), and then the fiber was further headspace exposed in exhaled gas in the Tedlar bag at 40degreesC for 4 min. Finally, the formed acetone oxime on the fiber was desorbed and analyzed by GC-MS. Using external standard method, acetone in the human breath was quantitatively analyzed by measurement of its oxime. The method provided a low detection limit of 0.049 ppbv for acetone in breath, relative standard deviation (R.S.D.) value of 3.4%, excellent accuracy. In addition, the method required simple sample preparation and no organic solvent. Acetone in diabetic breath was found to be higher than 1.71 ppmv, while its concentration in normal breath was lower than 0.76 ppmv. The results show that GC-MS and SPME with on-fiber derivatization is a simple, rapid and sensitive and solvent-free method for determination of low concentration acetone in breath and analysis of breath acetone can be used as supplementary tool for diagnosis of diabetes. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:269 / 275
页数:7
相关论文
共 33 条
  • [1] ANALYSIS OF ENVIRONMENTAL AIR SAMPLES BY SOLID-PHASE MICROEXTRACTION AND GAS-CHROMATOGRAPHY ION-TRAP MASS-SPECTROMETRY
    CHAI, M
    PAWLISZYN, J
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1995, 29 (03) : 693 - 701
  • [2] Crofford O B, 1977, Trans Am Clin Climatol Assoc, V88, P128
  • [3] Rapid determination of acetone in human plasma by gas chromatography-mass spectrometry and solid-phase microextraction with on-fiber derivatization
    Deng, CH
    Zhang, W
    Zhang, J
    Zhang, XM
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 805 (02): : 235 - 240
  • [4] Solid-phase microextraction for the analysis of human breath
    Grote, C
    Pawliszyn, J
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (04) : 587 - 596
  • [5] Hyspler R, 2000, J CHROMATOGR B, V739, P183
  • [6] On the mammalian acetone metabolism: from chemistry to clinical implications
    Kalapos, MP
    [J]. BIOCHIMICA ET BIOPHYSICA ACTA-GENERAL SUBJECTS, 2003, 1621 (02): : 122 - 139
  • [7] KNEEPKENS CMF, 1994, FREE RADICAL BIO MED, V17, P127
  • [8] BREAK ACETONE IN CONGESTIVE-HEART-FAILURE
    KUPARI, M
    LOMMI, J
    VENTILA, M
    KARJALAINEN, U
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1995, 76 (14) : 1076 - &
  • [9] Breath analysis and monitoring by membrane extraction with sorbent interface
    Lord, H
    Yu, YF
    Segal, A
    Pawliszyn, J
    [J]. ANALYTICAL CHEMISTRY, 2002, 74 (21) : 5650 - 5657
  • [10] DETERMINATION OF ALDEHYDES AND OTHER LIPID-PEROXIDATION PRODUCTS IN BIOLOGICAL SAMPLES BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY
    LUO, XP
    YAZDANPANAH, M
    BHOOI, N
    LEHOTAY, DC
    [J]. ANALYTICAL BIOCHEMISTRY, 1995, 228 (02) : 294 - 298