Objective: Heparin coating reduces complement activation on the surface of extracorporeal circuits, In this study we investigated its effect on activation of the contact system in 30 patients undergoing coronary artery bypass grafting with the use of a heparin-coated (Duraflo II, Baxter Healthcare Corp., Edwards Division, Santa Ana, Calif.; n = 15) or an uncoated extracorporeal circuit (n = 15), Methods: Plasma markers that reflect activation of contact (kallikrein-C1-inhibitor complexes), coagulation (prothrombin fragments F1+2), or fibrinolytic (plasmin-alpha(2)-antiplasmin complexes) systems were determined before and during the operation, The generation of kallikrein-C1-inhibitor complexes was reduced by 62% (p = 0.06) after the onset of cardiopulmonary bypass and by 43% (p = 0.026) after the cessation of bypass in the group in which a heparin-coated circuit was used compared with the group in which the circuit was uncoated, Generation was reduced by 58% (p = 0.06) when the ratio of kallikrein-C1-inhibitor to prekallikrein after onset of bypass was considered, We detected significant increases in F1+2 levels in both groups and increases in plasmin-alpha(2)-antiplasmin complexes in the heparin-coated group at cessation of bypass, but no intergroup differences were observed, Thus use of heparin-coated extracorporeal circuits during cardiac operations reduces formation of kallikrein-C1-inhibitor complexes when compared with use of uncoated circuits, The heparin coating is not accompanied by similar reductions in coagulation or fibrinolysis, suggesting that thrombin and plasmin formation during cardiopulmonary bypass occurs mainly independently of the contact system activation.
引用
收藏
页码:117 / 122
页数:6
相关论文
共 29 条
[21]  
RENT R, 1976, CLIN EXP IMMUNOL, V23, P264
[22]   CONTROL OF CONTACT ACTIVATION ON END-POINT IMMOBILIZED HEPARIN - THE ROLE OF ANTITHROMBIN AND THE SPECIFIC ANTITHROMBIN-BINDING SEQUENCE [J].
SANCHEZ, J ;
ELGUE, G ;
RIESENFELD, J ;
OLSSON, P .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1995, 29 (05) :655-661
[23]  
TEVELTHUIS H, 1996, ANN THORAC SURG, V61, P1153
[24]  
VIDEM V, 1992, J THORAC CARDIOV SUR, V103, P806
[25]  
WACHTFOGEL YT, 1989, BLOOD, V73, P468
[26]  
WACHTFOGEL YT, 1993, J THORAC CARDIOV SUR, V106, P1
[27]   SELECTIVE KALLIKREIN INHIBITORS ALTER HUMAN NEUTROPHIL ELASTASE RELEASE DURING EXTRACORPOREAL-CIRCULATION [J].
WACHTFOGEL, YT ;
HACK, CE ;
NUIJENS, JH ;
KETTNER, C ;
REILLY, TM ;
KNABB, RM ;
BISCHOFF, R ;
TSCHESCHE, H ;
WENZEL, H ;
KUCICH, U ;
EDMUNDS, LH ;
COLMAN, RW .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 1995, 268 (03) :H1352-H1357
[28]   HEPARIN-COATED CARDIOPULMONARY BYPASS CIRCUITS - HEMOSTATIC ALTERATIONS AND POSTOPERATIVE BLOOD-LOSS [J].
WAGNER, WR ;
JOHNSON, PC ;
THOMPSON, KA ;
MARRONE, GC .
ANNALS OF THORACIC SURGERY, 1994, 58 (03) :734-740
[29]   INACTIVATION OF FACTOR XIA IN HUMAN PLASMA ASSESSED BY MEASURING FACTOR XIA-PROTEASE INHIBITOR COMPLEXES - MAJOR ROLE FOR C1-INHIBITOR [J].
WUILLEMIN, WA ;
MINNEMA, M ;
MEIJERS, JCM ;
ROEM, D ;
EERENBERG, AJM ;
NUIJENS, JH ;
TENCATE, H ;
HACK, CE .
BLOOD, 1995, 85 (06) :1517-1526