An implantable MEMS drug delivery device for rapid delivery in ambulatory emergency care

被引:76
作者
Elman, N. M. [1 ]
Duc, H. L. Ho [1 ]
Cima, M. J. [1 ]
机构
[1] MIT, Dept Mat Sci & Engn, Cambridge, MA 02139 USA
关键词
MEMS; Drug delivery; Trauma care; Emergency; Micro-implant; Rapid delivery; Ambulatory emergency care; Cardiac device; Bolus; Subcutaneous; Cardiac; CARDIOVERTER-DEFIBRILLATOR; SYNCOPE; MICROCHIP; SURVIVAL;
D O I
10.1007/s10544-008-9272-6
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
We introduce the first implantable drug delivery system based on MEMS (Micro-Electro-Mechanical-Systems) technology specifically designed as a platform for treatment in ambulatory emergency care. The device is named IRD(3) (implantable rapid drug delivery device) and allows rapid delivery of drugs. Vasopressin was used as a model drug for in vitro tests as it is a commonly used drug for cardiac resuscitation. Experimental results reveal that the IRD(3) provides an effective method for rapid delivery without significant drug degradation. Several medical uses and delivery modalities for IRD(3) are proposed.
引用
收藏
页码:625 / 631
页数:7
相关论文
共 18 条
[1]
Aronow WS, 2003, J GERONTOL A-BIOL, V58, P927
[2]
Cavaco D, 2002, EUR HEART J, V23, P665
[3]
ELMAN NM, 2008, J MICROSYSTEM TECHNO, V14, P145
[4]
Improved survival in patients with nonischemic advanced heart failure and syncope treated with implantable cardioverter-defibrillator [J].
Fonarow, GC ;
Feliciano, Z ;
Boyle, NG ;
Knight, L ;
Woo, MA ;
Moriguchi, JD ;
Laks, H ;
Wiener, I .
AMERICAN JOURNAL OF CARDIOLOGY, 2000, 85 (08) :981-985
[5]
Evaluation of MEMS materials of construction for implantable medical devices [J].
Kotzar, G ;
Freas, M ;
Abel, P ;
Fleischman, A ;
Roy, S ;
Zorman, C ;
Moran, JM ;
Melzak, J .
BIOMATERIALS, 2002, 23 (13) :2737-2750
[6]
A new analytical solution for the load-deflection of square membranes [J].
MaierSchneider, D ;
Maibach, J ;
Obermeier, E .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 1995, 4 (04) :238-241
[7]
Electrothermally activated microchips for implantable drug delivery and biosensing [J].
Maloney, JM ;
Uhland, SA ;
Polito, BF ;
Sheppard, NF ;
Pelta, CM ;
Santini, JT .
JOURNAL OF CONTROLLED RELEASE, 2005, 109 (1-3) :244-255
[8]
Incidence of syncope after ICD implantation: low or high? [J].
Moran, Emilio Garcia ;
Mont, Lluis .
EUROPEAN HEART JOURNAL, 2006, 27 (20) :2481-2482
[9]
MEMS-micropumps: A review [J].
Nguyen, NT ;
Huang, XY ;
Chuan, TK .
JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2002, 124 (02) :384-392
[10]
Chronic, programmed polypeptide delivery from an implanted, multireservoir microchip device [J].
Prescott, JH ;
Lipka, S ;
Baldwin, S ;
Sheppard, NF ;
Maloney, JM ;
Coppeta, J ;
Yomtov, B ;
Staples, MA ;
Santini, JT .
NATURE BIOTECHNOLOGY, 2006, 24 (04) :437-438