Clinical Experience with a Single Catheter for Mapping and Ablation of Pulmonary Vein Ostium

被引:12
作者
De Filippo, Paolo
He, Ding Sheng [2 ]
Brambilla, Roberta
Gavazzi, Antonello
Cantu, Francesco [1 ]
机构
[1] Osped Riuniti Bergamo, Cardiovasc Dept, Cardiol Unit, I-24128 Bergamo, Italy
[2] Univ Arizona, Tucson, AZ USA
关键词
catheter ablation; atrial fibrillation; pulmonary vein isolation; mapping; mesh ablator; CIRCUMFERENTIAL ULTRASOUND ABLATION; PAROXYSMAL ATRIAL-FIBRILLATION; FIBEROPTIC BALLOON CATHETER; DOUBLE-LASSO TECHNIQUE; INITIAL-EXPERIENCE; NAVIGATION SYSTEM; ANATOMIC APPROACH; RADIOFREQUENCY ABLATION; CRYOABLATION CATHETER; ANTRUM ISOLATION;
D O I
10.1111/j.1540-8167.2008.01340.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A Single Catheter for Mapping and Ablation of Pulmonary Vein. Introduction: The aim of this single center study is to evaluate the safety and the efficacy of performing pulmonary vein isolation (PVI) using a single high-density mesh ablator (HDMA) catheter. Methods: A total of 17 consecutive patients with paroxysmal (10 patients) or persistent atrial fibrillation (7 patients) and no heart disease were enrolled. A single transseptal puncture was performed and the HDMA was placed at each PV ostium identified with anatomic and electrophysiological mapping. Pulsed radiofrequency (RF) energy was delivered at the targeted temperature of 58 degrees C with maximum power of 80 watts. No other ablation system was utilized. The primary objective of the study was acute isolation of the targeted PV, and the secondary objective was clinical efficacy and safety of PVI with HDMA for atrial fibrillation (AF) prevention. Patients were followed at intervals of 1, 3, 6, and 12 months. Results: PVI was attempted with HDMA in 67/67 PVs. [Correction made after online publication October 27, 2008: PVs changed from 6/67 to 67/67] Acute success rate were: 100% (16/16) for left superior PV, 100% (16/16) for left inferior PV, 100% (17/17) for right superior PV, 100% (1/1) for left common trunk and 47% (8/17) for right inferior PV. Total procedure time was 200 +/- 36 minutes (range 130-240 minutes) and total fluoroscopy time was 42 +/- 18 minutes (range 23-75 minutes). During a mean follow-up of 11 +/- 4 months, 64% of patients remained in sinus rhythm (8/10 paroxysmal AF and 3/7 for persistent AF). No complications occurred either acutely or at follow-up. Conclusions: PV isolation with HDMA is feasible and safe. The midterm efficacy in maintaining sinus rhythm is higher in paroxysmal than in persistent patients. (J Cardiovasc Electrophysiol, Vol. 20, pp. 367-373, April 2009).
引用
收藏
页码:367 / 373
页数:7
相关论文
共 33 条
[1]   Feasibility and safety of pulmonary vein isolation using a new mapping and navigation system in patients with refractory atrial fibrillation [J].
Arentz, T ;
von Rosenthal, J ;
Blum, T ;
Stockinger, J ;
Bürkle, G ;
Weber, R ;
Jander, N ;
Neumann, FJ ;
Kalusche, D .
CIRCULATION, 2003, 108 (20) :2484-2490
[2]   Effects of circumferential ostial radiofrequency lesions on pulmonary vein activation recorded with a multipolar basket catheter [J].
Arentz, T ;
Von Rosenthal, J ;
Weber, R ;
Bürkle, G ;
Blum, T ;
Stockinger, J ;
Neumann, FJ ;
Kalusche, D .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2005, 16 (03) :302-308
[3]   A novel mesh electrode catheter for mapping and radiofrequency delivery at the left atrium-pulmonary vein junction: A single-catheter approach to pulmonary vein antrum isolation [J].
Arruda, Mauricio S. ;
He, Ding Sheng ;
Friedman, Paul ;
Nakagawa, Hiroshi ;
Bruce, Charles ;
Azegami, Koji ;
Anders, Robert ;
Kozel, Peter ;
Chiavetta, Amedeo ;
Marad, Paul ;
Macadam, David ;
Jackman, Warren ;
Wilber, David J. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 (02) :206-211
[4]  
ARRUDA MS, 2001, PACE, V24, P633
[5]  
DEFILIPPO P, 2006, GIORNALE ITALIANO AR, V9, pS22
[6]   Laser ablation of the pulmonary veins by using a fiberoptic balloon catheter: Implications for treatment of paroxysmal atrial fibrillation [J].
Fried, NM ;
Tsitlik, A ;
Rent, KC ;
Berger, RD ;
Lardo, AC ;
Calkins, H ;
Halperin, HR .
LASERS IN SURGERY AND MEDICINE, 2001, 28 (03) :197-203
[7]  
FRIEDMAN PA, 2007, GIORNALE ITALIANO AR, V10, P53
[8]   Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins [J].
Haïssaguerre, M ;
Jaïs, P ;
Shah, DC ;
Takahashi, A ;
Hocini, M ;
Quiniou, G ;
Garrigue, S ;
Le Mouroux, A ;
Le Métayer, P ;
Clémenty, J .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (10) :659-666
[9]  
HE DS, CIRCULATION S, V98, P436
[10]   Empirical pulmonary vein isolation in patients with chronic atrial fibrillation using a three-dimensional nonfluoroscopic mapping system: Long-term follow-up [J].
Kanagaratnam, L ;
Tomassoni, G ;
Schweikert, R ;
Pavia, S ;
Bash, D ;
Beheiry, S ;
Lesh, M ;
Niebauer, M ;
Saliba, W ;
Chung, M ;
Tchou, P ;
Natale, A .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2001, 24 (12) :1774-1779