LC-MS-MS determination of exemestane in human plasma with heated nebulizer interface following solid-phase extraction in the 96 well plate format

被引:30
作者
Cenacchi, V [1 ]
Barattè, S [1 ]
Cicioni, P [1 ]
Frigerio, E [1 ]
Long, J [1 ]
James, C [1 ]
机构
[1] Pharmacia & Upjohn Inc, Drug Metab Res, I-20014 Milan, Italy
关键词
exemestane; human plasma; LC-MS-MS system; 96 well plate format;
D O I
10.1016/S0731-7085(00)00235-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A sensitive, specific and rapid analytical method for the quantitation of exemestane (EXE) in human plasma has been developed. EXE, 6-methylen-androsta-1,4-diene-3,17-dione, is an orally active irreversible steroidal aromatase inhibitor used for the therapy of metastatic postmenopausal breast cancer, with estrogen-dependent pathological conditions. The method involves extraction of EXE from human plasma by solid phase extraction using C2 endcapped sorbent in the 96 well plate format (50 mg/2 mi). After conditioning of the sorbent with 1 ml of acetonitrile (x2) the plates were rinsed with 1 ml of water (sl). The prepared samples (0.5 ml plasma, spiked with [C-13(3)] EXE as internal standard (IS) and diluted with 0.5 mi water) were loaded and drawn through the plate with a minimum of vacuum. The plates were then washed with 1 ml acetonitrile:water (10:90) followed by a drying step for 30 min at full vacuum. Elution was by 0.15 ml of 0.1% trifluoracetic acid in acetonitrile (x2) under a minimum of vacuum. Aliquots of 80 mu l were finally injected into the LC-MS-MS system. A Zorbax SE C8 column (4.6 x 150 mm, 5 mu m) was used to perform the chromatographic separation; the mobile phase was 100% acetonitrile. RIS detection used the heated nebulizer interface, with multiple reaction monitoring (MRM) (297 --> 121 m/z for EXE and 300 --> 123 m/z for IS) operated in positive ion mode. A weighed linear regression analysis (weighing factor 1/x(2)) was used to calculate EXE concentration in standard and unknown samples. The method was fully validated in the concentration range 0.05-25 ng ml(-1). (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:451 / 460
页数:10
相关论文
共 8 条
[1]   DETERMINATION OF PLASMA-LEVELS OF EXEMESTANE (FCE-24304), A NEW IRREVERSIBLE AROMATASE INHIBITOR, USING THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
ALLIEVI, C ;
ZUGNONI, P ;
BENEDETTI, MS ;
DOSTERT, P .
JOURNAL OF MASS SPECTROMETRY, 1995, 30 (05) :693-697
[2]   DETERMINATION OF EXEMESTANE, A NEW AROMATASE INHIBITOR, IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ULTRAVIOLET DETECTION [J].
BREDA, M ;
PIANEZZOLA, E ;
BENEDETTI, MS .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 620 (02) :225-231
[3]   AROMATASE AND ITS INHIBITORS IN BREAST-CANCER-TREATMENT - OVERVIEW AND PERSPECTIVE [J].
BRODIE, AMH ;
SANTEN, RJ .
BREAST CANCER RESEARCH AND TREATMENT, 1994, 30 (01) :1-6
[4]   AROMATASE IN BREAST-CANCER AND THE ROLE OF AMINOGLUTETHIMIDE AND OTHER AROMATASE INHIBITORS [J].
BRODIE, AMH ;
SANTEN, RJ .
CRC CRITICAL REVIEWS IN ONCOLOGY/HEMATOLOGY, 1986, 5 (04) :361-396
[5]   EXEMESTANE (FCE-24304), A NEW STEROIDAL AROMATASE INHIBITOR [J].
DISALLE, E ;
ORNATI, G ;
GIUDICI, D ;
LASSUS, M ;
EVANS, TRJ ;
COOMBES, RC .
JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 1992, 43 (1-3) :137-143
[6]   6-METHYLENANDROSTA-1,4-DIENE-3,17-DIONE (FCE 24304) - A NEW IRREVERSIBLE AROMATASE INHIBITOR [J].
GIUDICI, D ;
ORNATI, G ;
BRIATICO, G ;
BUZZETTI, F ;
LOMBARDI, P ;
DISALLE, E .
JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 1988, 30 (1-6) :391-394
[7]   Determination of the new aromatase inhibitor exemestane in biological fluids by automated high-performance liquid chromatography followed by radioimmunoassay [J].
Persiani, S ;
Broutin, F ;
Cicioni, P ;
Benedetti, MS .
EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 1996, 4 (06) :331-340
[8]  
Segaloff A., 1978, ADV RES TREATMENT, P1