MRI-derived measurements of human subcortical, ventricular and intracranial brain volumes: Reliability effects of scan sessions, acquisition sequences, data analyses, scanner upgrade, scanner vendors and field strengths

被引:431
作者
Jovicich, Jorge [1 ]
Czanner, Silvester [2 ]
Han, Xiao [3 ]
Salat, David [4 ,6 ]
van der Kouwe, Andre [4 ,6 ]
Quinn, Brian [4 ,6 ]
Pacheco, Jenni [4 ,6 ]
Albert, Marilyn [8 ]
Killiany, Ronald [9 ]
Blacker, Deborah [6 ,7 ]
Maguire, Paul [10 ]
Rosas, Diana [4 ,5 ,6 ]
Makris, Nikos [4 ,6 ,11 ]
Gollub, Randy [4 ,6 ]
Dale, Anders [12 ]
Dickerson, Bradford C. [5 ,6 ,7 ,13 ]
Fischl, Bruce [4 ,6 ,14 ]
机构
[1] Univ Trento, Dept Cognit & Educ Sci, Ctr Mind Brain Sci, Trento, Italy
[2] Univ Warwick, Sch Engn, Warwick Mfg Grp, Coventry CV4 7AL, W Midlands, England
[3] CMS Inc, St Louis, MO USA
[4] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[5] Massachusetts Gen Hosp, Dept Neurol, Boston, MA 02114 USA
[6] Harvard Univ, Sch Med, Boston, MA USA
[7] Massachusetts Gen Hosp, Dept Psychiat, Gerontol Res Unit, Boston, MA 02114 USA
[8] Johns Hopkins Univ, Sch Med, Dept Neurol, Baltimore, MD 21218 USA
[9] Boston Univ, Sch Med, Dept Anat & Neurobiol, Boston, MA 02215 USA
[10] Pfizer Global Res & Dev, Groton, CT USA
[11] Massachusetts Gen Hosp, Ctr Morphometr Anal, Boston, MA 02114 USA
[12] Univ Calif San Diego, La Jolla, CA 92093 USA
[13] Brigham & Womens Hosp, Dept Neurol, Div Cognit & Behav Neurol, Boston, MA 02115 USA
[14] MIT, CSAIL HST, Cambridge, MA 02139 USA
关键词
Subcortical brain volumes; Reproducibility; Reliability; Structural MRI; Cerebral cortex; Morphology; VOXEL-BASED MORPHOMETRY; HUNTINGTONS-DISEASE; STRUCTURAL NEUROPATHOLOGY; CEREBRAL ATROPHY; PROGRESSION; SEGMENTATION; DEMENTIA; SHAPE;
D O I
10.1016/j.neuroimage.2009.02.010
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Automated MRI-derived measurements of in-vivo human brain volumes provide novel insights into normal and abnormal neuroanatomy, but little is known about measurement reliability. Here we assess the impact of image acquisition variables (scan session, MRI sequence, scanner upgrade, vendor and field strengths), FreeSurfer segmentation pre-processing variables (image averaging, B1 field inhomogeneity correction) and segmentation analysis variables (probabilistic atlas) on resultant image segmentation volumes from older (n = 15, mean age 69.5) and younger (both n = 5, mean ages 34 and 36.5) healthy subjects. The variability between hippocampal, thalamic, caudate, putamen, lateral ventricular and total intracranial volume measures across sessions on the same scanner on different days is less than 4.3% for the older group and less than 2.3% for the younger group. Within-scanner measurements are remarkably reliable across scan sessions, being minimally affected by averaging of multiple acquisitions, B1 correction, acquisition sequence (MPRAGE vs. multi-echo-FLASH), major scanner upgrades (Sonata-Avanto, Trio-TrioTIM), and segmentation atlas (MPRAGE or multi-echo-FLASH). Volume measurements across platforms (Siemens Sonata vs. GE Signa) and field strengths (1.5 T vs. 3 T) result in a volume difference bias but with a comparable variance as that measured within-scanner, implying that multi-site studies may not necessarily require a much larger sample to detect a specific effect. These results suggest that volumes derived from automated segmentation of T1-weighted structural images are reliable measures within the same scanner platform, even after upgrades; however, combining data across platform and across field-strength introduces a bias that should be considered in the design of multi-site studies, such as clinical drug trials. The results derived from the young groups (scanner upgrade effects and B1 inhomogeneity correction effects) should be considered as preliminary and in need for further validation with a larger dataset. (C) 2009 Elsevier Inc. All rights reserved.
引用
收藏
页码:177 / 192
页数:16
相关论文
共 62 条
[1]  
ALECCI M, 2000, P 8 ANN M ISMRM DENV, P109
[2]  
ALEMANGOMEZ Y, 2007, HUM BRAIN MAPP 12 AN
[3]   Cerebral atrophy measurement in clinically isolated syndromes and relapsing remitting multiple sclerosis: A comparison of registration-based methods [J].
Anderson, Valerie M. ;
Fernando, Kryshani T. M. ;
Davies, Gerard R. ;
Rashid, Waqar ;
Frost, Chris ;
Fox, Nick C. .
JOURNAL OF NEUROIMAGING, 2007, 17 (01) :61-68
[4]   The role of volumetric MRI in understanding mild cognitive impairment and similar classifications [J].
Anstey, KJ ;
Maller, JJ .
AGING & MENTAL HEALTH, 2003, 7 (04) :238-250
[5]   Voxel-based morphometry - The methods [J].
Ashburner, J ;
Friston, KJ .
NEUROIMAGE, 2000, 11 (06) :805-821
[6]   Automated measurement of hippocampal atrophy using fluid-registered serial MRI in AD and controls [J].
Barnes, Josephine ;
Lewis, Emma B. ;
Scahill, Rachael I. ;
Bartlett, Jonathan W. ;
Frost, Chris ;
Schott, Jonathan M. ;
Rossor, Martin N. ;
Fox, Nick C. .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2007, 31 (04) :581-587
[7]   Offering to share: How to put heads together in autism neuroimaging [J].
Belmonte, Matthew K. ;
Mazziotta, John C. ;
Minshew, Nancy J. ;
Evans, Alan C. ;
Courchesne, Eric ;
Dager, Stephen R. ;
Bookheimer, Susan Y. ;
Aylward, Elizabeth H. ;
Amaral, David G. ;
Cantor, Rita M. ;
Chugani, Diane C. ;
Dale, Anders M. ;
Davatzikos, Christos ;
Gerig, Guido ;
Herbert, Martha R. ;
Lainhart, Janet E. ;
Murphy, Declan G. ;
Piven, Joseph ;
Reiss, Allan L. ;
Schultz, Robert T. ;
Zeffiro, Thomas A. ;
Levi-Pearl, Susan ;
Lajonchere, Clara ;
Colamarino, Sophia A. .
JOURNAL OF AUTISM AND DEVELOPMENTAL DISORDERS, 2008, 38 (01) :2-13
[8]   Comparison of manual and automatic section positioning of brain MR images [J].
Benner, T ;
Wisco, JJ ;
van der Kouwe, AJW ;
Fischl, B ;
Vangel, MG ;
Hochberg, FH ;
Sorensen, AG .
RADIOLOGY, 2006, 239 (01) :246-254
[9]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[10]  
Camara O, 2007, LECT NOTES COMPUT SC, V4792, P785