Improvements in ion signal reproducibility obtained using a homogeneous laser beam for on-line laser desorption/ionization of single particles

被引:1
作者
Wenzel, RJ
Prather, KA [1 ]
机构
[1] Univ Calif San Diego, Dept Chem & Biochem, La Jolla, CA 92093 USA
[2] Univ Calif Riverside, Dept Chem, Riverside, CA 92521 USA
关键词
D O I
10.1002/rcm.1509
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A major factor limiting on-line single particle mass spectrometry techniques from becoming more quantitative is the large shot-to-shot variability in ion intensities observed in the laser desorption/ionization (LDI) mass spectra. 1,2 In previous work, lab-generated particles showed fluctuations of up to 152% in the absolute ion intensities in averaged spectra of 200-300 'identical' particles.(2) Most of these fluctuations were attributed to inhomogeneities in the laser beam profile, leading to significant differences in the power each particle encountered depending on the position in the LDI laser beam where it underwent analysis. The goal of the work presented herein is to determine whether a fiber optic actually reduces the observed variability in single particle LDI mass spectral data. Initial results are presented for individual single component organic particles composed of 2,4-dihydroxybenzoic acid (2,4-DHB) analyzed using a low-power flat-top laser beam profile created by sending an ultraviolet (266 nm) DI laser through a fiber optic. Relative standard deviations of the total ion intensities for peaks in individual spectra are reduced to 31%. Single particle spectra, compared with and without laser homogenization at the same nominal laser fluence, show a marked enhancement. Specifically, the ion signal patterns of the 2,4-DHB particle spectra obtained using a homogenous LDI beam look identical to one another (i.e. only one particle type was produced with a commonly used neural network grouping algorithm), whereas without beam homogenization 25 different particle types (based on ion intensity patterns) were obtained. Future publications will explore more particle types and matrices but the initial results described herein are quite encouraging. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:1525 / 1533
页数:9
相关论文
共 33 条
[1]   MATRIX-ASSISTED ULTRAVIOLET-LASER DESORPTION - EVOLUTION AND PRINCIPLES [J].
BEAVIS, RC .
ORGANIC MASS SPECTROMETRY, 1992, 27 (06) :653-659
[2]   Source apportionment of fine particulate matter by clustering single-particle data: Tests of receptor model accuracy [J].
Bhave, PV ;
Fergenson, DP ;
Prather, KA ;
Cass, GR .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2001, 35 (10) :2060-2072
[3]   Time-of-flight mass spectrometric analysis of ions produced from adjacent sample spots irradiated simultaneously by a single 337 nm laser [J].
Bogan, MJ ;
Agnes, GR .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (22) :2557-2562
[4]   Infrared multiphoton dissociation with a hollow fiber waveguide [J].
Drader, JJ ;
Hannis, JC ;
Hofstadler, SA .
ANALYTICAL CHEMISTRY, 2003, 75 (15) :3669-3674
[5]   INFLUENCE OF THE LASER INTENSITY AND SPOT SIZE ON THE DESORPTION OF MOLECULES AND IONS IN MATRIX-ASSISTED LASER-DESORPTION IONIZATION WITH A UNIFORM BEAM PROFILE [J].
DREISEWERD, K ;
SCHURENBERG, M ;
KARAS, M ;
HILLENKAMP, F .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 1995, 141 (02) :127-148
[6]   The desorption process in MALDI [J].
Dreisewerd, K .
CHEMICAL REVIEWS, 2003, 103 (02) :395-425
[7]   EFFECTS OF LASER-BEAM PARAMETERS IN LASER ION MOBILITY SPECTROMETRY [J].
EICEMAN, GA ;
VANDIVER, VJ ;
LEASURE, CS ;
ANDERSON, GK ;
TIEE, JJ ;
DANEN, WC .
ANALYTICAL CHEMISTRY, 1986, 58 (08) :1690-1695
[8]   Real-time analysis of individual atmospheric aerosol particles: Design and performance of a portable ATOFMS [J].
Gard, E ;
Mayer, JE ;
Morrical, BD ;
Dienes, T ;
Fergenson, DP ;
Prather, KA .
ANALYTICAL CHEMISTRY, 1997, 69 (20) :4083-4091
[9]   Relative sensitivity factors for alkali metal and ammonium cations in single particle aerosol time-of-flight mass spectra [J].
Gross, DS ;
Gälli, ME ;
Silva, PJ ;
Prather, KA .
ANALYTICAL CHEMISTRY, 2000, 72 (02) :416-422
[10]   Capabilities of a homogenized 266 nm Nd:YAG laser ablation system for LA-ICP-MS [J].
Guillong, M ;
Horn, I ;
Günther, D .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (01) :8-14