We introduce capillary electrophoresis-mass spectrometry (CE-MS) as an efficient means for the on-line separation and identification of protein mixtures. It was found that while CE/electrospray ionization (ESI)-MS analysis of whole-cell lysate was too complicated for the one-dimensional CE-MS analysis, the technique was useful for the analysis of protein mixtures of moderate complexity (similar to50 intact proteins). CE/ESI-MS was applied to the subcellular proteomics of ribosomal Escherichia coli. 55 out of the 56 ribosomal proteins were detected with ease by using only similar to3.4 ng of ribosomal proteins. In addition, it was found that the mass accuracy of the conventional MS (such as quadrupole ion traps) was good enough to identify many post-translational modifications of the intact proteins by simply comparing their measured average molecular weight with the average molecular weight predicted from gene banks.
引用
收藏
页码:1981 / 1987
页数:7
相关论文
共 24 条
[1]   Observation of Escherichia coli ribosomal proteins and their posttranslational modifications by mass spectrometry [J].
Arnold, RJ ;
Reilly, JP .
ANALYTICAL BIOCHEMISTRY, 1999, 269 (01) :105-112
[2]   Mass spectrometry of ribosomes and ribosomal subunits [J].
Benjamin, DR ;
Robinson, CV ;
Hendrick, JP ;
Hartl, FU ;
Dobson, CM .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1998, 95 (13) :7391-7395
[3]   Pressure-assisted and pressure-programmed capillary electrophoresis/electrospray ionization time of flight - mass spectrometry for the analysis of peptide mixtures [J].
Cao, P ;
Moini, M .
ELECTROPHORESIS, 1998, 19 (12) :2200-2206
[4]  
Chong BE, 1997, RAPID COMMUN MASS SP, V11, P1900, DOI 10.1002/(SICI)1097-0231(199711)11:17<1900::AID-RCM95>3.0.CO
[5]  
2-K
[6]   Probing proteomes using capillary isoelectric focusing-electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry [J].
Jensen, PK ;
Pasa-Tolic, L ;
Anderson, GA ;
Horner, JA ;
Lipton, MS ;
Bruce, JE ;
Smith, RD .
ANALYTICAL CHEMISTRY, 1999, 71 (11) :2076-2084
[7]   Top down versus bottom up protein characterization by tandem high-resolution mass spectrometry [J].
Kelleher, NL ;
Lin, HY ;
Valaskovic, GA ;
Aaserud, DJ ;
Fridriksson, EK ;
McLafferty, FW .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1999, 121 (04) :806-812
[8]   Shotgun proteomics and biomarker discovery [J].
McDonald, WH ;
Yates, JR .
DISEASE MARKERS, 2002, 18 (02) :99-105
[9]   Design and performance of a universal sheathless capillary electrophoresis to mass spectrometry interface using a split-flow technique [J].
Moini, M .
ANALYTICAL CHEMISTRY, 2001, 73 (14) :3497-3501
[10]   Analysis of carbonic anhydrase in human red blood cells using capillary electrophoresis/electrospray ionization-mass spectrometry [J].
Moini, M ;
Demars, SM ;
Huang, HL .
ANALYTICAL CHEMISTRY, 2002, 74 (15) :3772-3776