Dynamic elastic modulus of porcine articular cartilage determined at two different levels of tissue organization by indentation-type atomic force microscopy

被引:377
作者
Stolz, M
Raiteri, R
Daniels, AU
VanLandingham, MR
Baschong, W
Aebi, U
机构
[1] Univ Basel, Biozentrum, ME Muller Inst Struct Biol, CH-4056 Basel, Switzerland
[2] Univ Genoa, Dept Biophys & Elect Engn, Genoa, Italy
[3] Univ Basel, Felix Platter Hosp, Lab Orthoped Biomech, CH-4003 Basel, Switzerland
[4] Army Res Lab, Aberdeen Proving Ground, MD USA
[5] Univ Basel, Dept Oral Surg, CH-4003 Basel, Switzerland
关键词
D O I
10.1016/S0006-3495(04)74375-1
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Cartilage stiffness was measured ex vivo at the micrometer and nanometer scales to explore structure-mechanical property relationships at smaller scales than has been done previously. A method was developed to measure the dynamic elastic modulus, \E*\, in compression by indentation-type atomic force microscopy (IT AFM). Spherical indenter tips (radius=similar to2.5 mum) and sharp pyramidal tips (radius=similar to20 nm) were employed to probe micrometer-scale and nanometer-scale response, respectively. \E*\ values were obtained at 3 Hz from 1024 unloading response curves recorded at a given location on subsurface cartilage from porcine femoral condyles. With the microsphere tips, the average modulus was similar to2.6 MPa, in agreement with available millimeter-scale data, whereas with the sharp pyramidal tips, it was typically 100-fold lower. In contrast to cartilage, measurements made on agarose gels, a much more molecularly amorphous biomaterial, resulted in the same average modulus for both indentation tips. From results of AFM imaging of cartilage, the micrometer-scale spherical tips resolved no. ne structure except some chondrocytes, whereas the nanometer-scale pyramidal tips resolved individual collagen fibers and their 67-nm axial repeat distance. These results suggest that the spherical AFM tip is large enough to measure the aggregate dynamic elastic modulus of cartilage, whereas the sharp AFM tip depicts the elastic properties of its. ne structure. Additional measurements of cartilage stiffness following enzyme action revealed that elastase digestion of the collagen moiety lowered the modulus at the micrometer scale. In contrast, digestion of the proteoglycans moiety by cathepsin D had little effect on \E*\ at the micrometer scale, but yielded a clear stiffening at the nanometer scale. Thus, cartilage compressive stiffness is different at the nanometer scale compared to the overall structural stiffness measured at the micrometer and larger scales because of the fine nanometer-scale structure, and enzyme-induced structural changes can affect this scale-dependent stiffness differently.
引用
收藏
页码:3269 / 3283
页数:15
相关论文
共 58 条
[1]   Relative microelastic mapping of living cells by atomic force microscopy [J].
A-Hassan, E ;
Heinz, WF ;
Antonik, MD ;
D'Costa, NP ;
Nageswaran, S ;
Schoenenberger, CA ;
Hoh, JH .
BIOPHYSICAL JOURNAL, 1998, 74 (03) :1564-1578
[2]   The accuracy and reliability of a novel handheld dynamic indentation probe for analysing articular cartilage [J].
Appleyard, RC ;
Swain, MV ;
Khanna, S ;
Murrell, GAC .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (02) :541-550
[3]   COMPUTER-CONTROLLED MECHANICAL TESTING MACHINE FOR SMALL SAMPLES OF BIOLOGICAL VISCOELASTIC MATERIALS [J].
ASPDEN, RM ;
LARSSON, T ;
SVENSSON, R ;
HEINEGARD, D .
JOURNAL OF BIOMEDICAL ENGINEERING, 1991, 13 (06) :521-525
[4]  
BADER DL, 1994, BIO-MED MATER ENG, V4, P245
[5]  
Bueckle H., 1973, SCI HARDNESS TESTING
[6]   Force-distance curves by AFM - A powerful technique for studying surface interactions [J].
Capella, B ;
Baschieri, P ;
Frediani, C ;
Miccoli, P ;
Ascoli, C .
IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1997, 16 (02) :58-65
[7]   A NONDESTRUCTIVE METHOD FOR DETERMINING THE SPRING CONSTANT OF CANTILEVERS FOR SCANNING FORCE MICROSCOPY [J].
CLEVELAND, JP ;
MANNE, S ;
BOCEK, D ;
HANSMA, PK .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (02) :403-405
[8]   Composition and dynamics of articular cartilage: Structure, function, and maintaining healthy state [J].
Cohen, NP ;
Foster, RJ ;
Mow, VC .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1998, 28 (04) :203-215
[9]   Determination of the spring constants of probes for force microscopy/spectroscopy [J].
Gibson, CT ;
Watson, GS ;
Myhra, S .
NANOTECHNOLOGY, 1996, 7 (03) :259-262
[10]  
Hay JL, 2000, ASM Handbook: Mechanical Testing and Evaluation, P232, DOI [10.31399/asm.hb.v08.a0003273, DOI 10.31399/ASM.HB.V08.A0003273, DOI 10.31399/asm.hb.v08.a0003273]