Surface EMG signal processing during isometric contractions

被引:179
作者
Merletti, R [1 ]
LoConte, LR [1 ]
机构
[1] BOSTON UNIV, BOSTON, MA 02215 USA
关键词
muscle fatigue; electromyography; signal processing;
D O I
10.1016/S1050-6411(97)00010-2
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
This paper provides an overview of techniques suitable for the estimation, interpretation and understanding of time variations that affect the surface electromyographic (EMG) Signal during sustained voluntary or electrically elicited contractions. These variations concern amplitude variables, spectral variables and muscle fiber conduction velocity, are interdependent and are referred to as the 'fatigue plot'. The fatigue plot provides information suitable for the classification of muscle behavior. In addition, the information obtainable by means of linear electrode arrays is discussed, and applications of mathematical models for the interpretation of array signals are presented. The model approach provides additional ways for the classification of muscle behavior. (C) 1997 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:241 / 250
页数:10
相关论文
共 37 条
[11]   Linear and quadratic time-frequency signal representations [J].
Hlawatsch, F. ;
Boudreaux-Bartels, G. F. .
IEEE SIGNAL PROCESSING MAGAZINE, 1992, 9 (02) :21-67
[12]   A RESOLUTION COMPARISON OF SEVERAL TIME-FREQUENCY REPRESENTATIONS [J].
JONES, DL ;
PARKS, TW .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 1992, 40 (02) :413-420
[13]  
KANEKO H, 1995, IEICE T FUNDAM, V79, P373
[14]   A MUSCLE FATIGUE INDEX BASED ON THE RELATIONSHIP BETWEEN PRECEDING BACKGROUND ACTIVITY AND MYOTATIC REFLEX RESPONSE (MRR) [J].
KIRYU, T ;
SAITOH, Y ;
ISHIOKA, K .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (02) :105-111
[15]  
KOSTOV K, 1984, Electromyography and Clinical Neurophysiology, V24, P387
[16]   EFFECTS OF MUSCLE-FIBER TYPE AND SIZE ON EMG MEDIAN FREQUENCY AND CONDUCTION-VELOCITY [J].
KUPA, EJ ;
ROY, SH ;
KANDARIAN, SC ;
DE LUCA, CJ .
JOURNAL OF APPLIED PHYSIOLOGY, 1995, 79 (01) :23-32
[17]   COMPARISON OF 3 RUNNING SPECTRAL-ANALYSIS METHODS FOR ELECTROGASTROGRAPHIC SIGNALS [J].
LIN, ZY ;
CHEN, JDZ .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1995, 33 (04) :596-604
[18]   INTERPRETATION OF MYOELECTRIC POWER SPECTRA - MODEL AND ITS APPLICATIONS [J].
LINDSTROM, LH ;
MAGNUSSON, RI .
PROCEEDINGS OF THE IEEE, 1977, 65 (05) :653-662
[19]   HERMITE EXPANSIONS OF COMPACT SUPPORT WAVE-FORMS - APPLICATIONS TO MYOELECTRIC SIGNALS [J].
LOCONTE, LR ;
MERLETTI, R ;
SANDRI, GV .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1994, 41 (12) :1147-1159
[20]   A SURFACE ELECTRODE ARRAY FOR DETECTING ACTION-POTENTIAL TRAINS OF SINGLE MOTOR UNITS [J].
MASUDA, T ;
MIYANO, H ;
SADOYAMA, T .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1985, 60 (05) :435-443