Spatial domain method for the design of RF pulses in multicoil parallel excitation

被引:278
作者
Grissom, William
Yip, Chun-yu
Zhang, Zhenghui
Stenger, V. Andrew
Fessler, Jeffrey A.
Noll, Douglas C.
机构
[1] Univ Michigan, Funct MRI Lab, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Biomed Engn, Ann Arbor, MI 48109 USA
[3] Univ Michigan, Dept Elect Engn & Comp Sci, Ann Arbor, MI 48109 USA
[4] Univ Pittsburgh, Dept Bioengn, Pittsburgh, PA USA
[5] Univ Hawaii Manoa, Dept Med, Honolulu, HI 96822 USA
关键词
transmit SENSE; parallel excitation; pulse design; selective excitation; large-tip-angle excitation;
D O I
10.1002/mrm.20978
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 [临床医学]; 100207 [影像医学与核医学]; 1009 [特种医学];
摘要
Parallel excitation has been introduced as a means of accelerating multidimensional, spatially-selective excitation using multiple transmit coils, each driven by a unique RF pulse. Previous approaches to RF pulse design in parallel excitation were either formulated in the frequency domain or restricted to echo-planar trajectories, or both. This paper presents an approach that is formulated as a quadratic optimization problem in the spatial domain and allows the use of arbitrary k-space trajectories. Compared to frequency domain approaches, the new design method has some important advantages. It allows for the specification of a region of interest (ROI), which improves excitation accuracy at high speedup factors. It allows for magnetic field inhomogeneity compensation during excitation. Regularization may be used to control integrated and peak pulse power. The effects of Bloch equation nonlinearity on the large-tip-angle excitation error of RF pulses designed with the method are investigated, and the utility of Tikhonov regularization in mitigating this error is demonstrated.
引用
收藏
页码:620 / 629
页数:10
相关论文
共 22 条
[1]
Conjugate gradient methods for toeplitz systems [J].
Chan, RH ;
Ng, MK .
SIAM REVIEW, 1996, 38 (03) :427-482
[2]
FESSLER JA, 2006, P IEEE INT S BIOM IM, P1015
[3]
GRISWOLD M, 2005, P 13 ANN M ISMRM MIA, P2435
[4]
Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[5]
Transmit SENSE [J].
Katscher, U ;
Börnert, P ;
Leussler, C ;
van den Brink, JS .
MAGNETIC RESONANCE IN MEDICINE, 2003, 49 (01) :144-150
[6]
KATSCHER U, 2005, P 13 ANN M ISMRM MIA, P2256
[7]
A HOMOGENEITY CORRECTION METHOD FOR MAGNETIC-RESONANCE-IMAGING WITH TIME-VARYING GRADIENTS [J].
NOLL, DC ;
MEYER, CH ;
PAULY, JM ;
NISHIMURA, DG ;
MACOVSKI, A .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (04) :629-637
[8]
A LINEAR CLASS OF LARGE-TIP-ANGLE SELECTIVE EXCITATION PULSES [J].
PAULY, J ;
NISHIMURA, D ;
MACOVSKI, A .
JOURNAL OF MAGNETIC RESONANCE, 1989, 82 (03) :571-587
[9]
A K-SPACE ANALYSIS OF SMALL-TIP-ANGLE EXCITATION [J].
PAULY, J ;
NISHIMURA, D ;
MACOVSKI, A .
JOURNAL OF MAGNETIC RESONANCE, 1989, 81 (01) :43-56
[10]
Pruessmann KP, 1999, MAGNET RESON MED, V42, P952, DOI 10.1002/(SICI)1522-2594(199911)42:5<952::AID-MRM16>3.0.CO