Monte Carlo-based down-scatter correction of SPECT attenuation maps

被引:4
作者
Bokuli, T
Vastenhouw, B
de Jong, HWAM
van Dongen, AJ
van Rijk, PP
Beekman, FJ
机构
[1] Univ Med Ctr Utrecht, Image Sci Inst, Dept Nucl Med, Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Rudolf Magnus Inst Neurosci, Utrecht, Netherlands
[3] Univ Hosp Sestre Milosrdnice, Dept Oncol & Nucl Med, Zagreb, Croatia
[4] Vrije Univ Amsterdam Med Ctr, Clin PET Ctr, Amsterdam, Netherlands
关键词
quantitative SPECT; attenuation correction; Monte Carlo simulation; scatter correction; cardiac imaging;
D O I
10.1007/s00259-004-1507-z
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Combined acquisition of transmission and emission data in single-photon emission computed tomography (SPECT) can be used for correction of non-uniform photon attenuation. However, down-scatter from a higher energy isotope (e.g. Tc-99m) contaminates lower energy transmission data (e.g. Gd-153, 100 keV), resulting in underestimation of reconstructed attenuation coefficients. Window-based corrections are often not very accurate and increase noise in attenuation maps. We have developed a new correction scheme. It uses accurate scatter modelling to avoid noise amplification and does not require additional energy windows. The correction works as follows: Initially, an approximate attenuation map is reconstructed using down-scatter contaminated transmission data (step 1). An emission map is reconstructed based on the contaminated attenuation map (step 2). Based on this approximate Tc-99m reconstruction and attenuation map, down-scatter in the 153Gd window is simulated using accelerated Monte Carlo simulation (step 3). This down-scatter estimate is used during reconstruction of a corrected attenuation map (step 4). Based on the corrected attenuation map, an improved Tc-99m image is reconstructed (step.5). Steps 3-5 are repeated to incrementally improve the down-scatter estimate. The Monte Carlo simulator provides accurate down-scatter estimation with significantly less noise than down-scatter estimates acquired in an additional window. Errors in the reconstructed attenuation coefficients are reduced from ca. 40% to less than 5%. Furthermore, artefacts in Tc-99m emission reconstructions are almost completely removed. These results are better than for window-based correction, both in simulation experiments and in physical phantom experiments. Monte Carlo down-scatter simulation in concert with statistical reconstruction provides accurate down-scatter correction of attenuation maps.
引用
收藏
页码:1173 / 1181
页数:9
相关论文
共 27 条
[21]   A multicenter evaluation of commercial attenuation compensation techniques in cardiac SPECT using phantom models [J].
O'Connor, MK ;
Kemp, B ;
Anstett, F ;
Christian, P ;
Ficaro, EP ;
Frey, E ;
Jacobs, M ;
Kritzman, JN ;
Pooley, RA ;
Wilk, M .
JOURNAL OF NUCLEAR CARDIOLOGY, 2002, 9 (04) :361-376
[22]  
OGAWA K, 1985, JPN J NUCL MED, V22, P477
[23]  
TAN P, 1993, J NUCL MED, V34, P1752
[24]   QUANTITATIVE CARDIAC SPECT RECONSTRUCTION WITH REDUCED IMAGE DEGRADATION DUE TO PATIENT ANATOMY [J].
TSUI, BMW ;
ZHAO, XD ;
GREGORIOU, GK ;
LALUSH, DS ;
FREY, EC ;
JOHNSTON, RE ;
MCCARTNEY, WH .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1994, 41 (06) :2838-2844
[25]  
TSUI BMW, 1989, J NUCL MED, V30, P497
[26]   A SIMULATION OF EMISSION AND TRANSMISSION NOISE-PROPAGATION IN CARDIAC SPECT IMAGING WITH NONUNIFORM ATTENUATION CORRECTION [J].
TUNG, CH ;
GULLBERG, GT .
MEDICAL PHYSICS, 1994, 21 (10) :1565-1576
[27]  
Zaidi H, 2003, J NUCL MED, V44, P291