Intraoperative ultrasound for guidance and tissue shift correction in image-guided neurosurgery

被引:197
作者
Comeau, RM
Sadikot, AF
Fenster, A
Peters, TM
机构
[1] McGill Univ, Montreal Neurol Inst, McConnell Brain Imaging Ctr, Montreal, PQ H3A 2B4, Canada
[2] McGill Univ, Dept Biomed Engn, Montreal, PQ H3A 2B4, Canada
[3] McGill Univ, Montreal Neurol Inst, Dept Neurol & Neurosurg, Montreal, PQ H3A 2B4, Canada
[4] Univ Western Ontario, John P Robarts Res LAbs, Imaging Res Labs, London, ON N6A 5K8, Canada
关键词
image-guided surgery; ultrasound; tissue deformation; image warping; image registration; neurosurgery; intraoperative imaging;
D O I
10.1118/1.598942
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We present a surgical guidance system that incorporates pre-operative image information (e.g., MRI) with intraoperative ultrasound (US) imaging to detect and correct for brain tissue deformation during image-guided neurosurgery (IGNS). Many interactive IGNS implementations employ preoperative images as a guide to the surgeons throughout the procedure. However, when a craniotomy is involved, tissue movement during a procedure can be a significant source of error in these systems. By incorporating intraoperative US imaging, the target volume can be scanned at any time, and two-dimensional US images may be compared directly to the corresponding slice from the pre-operative image. Homologous points may be mapped from the intraoperative to the preoperative image space with an accuracy of better than 2 mm, enabling the surgeon to use this information to assess the accuracy of the guidance system along with the progress of the procedure (e.g., extent of lesion removal) at any time during the operation. Anatomical features may be identified on both the pre-operative and intraoperative images and used to generate a deformation map, which can be used to warp the pre-operative image to match the intraoperative US image. System validation is achieved using a deformable multi-modality imaging phantom, and preliminary clinical results are presented. (C) 2000 American Association of Physicists in Medicine.
引用
收藏
页码:787 / 800
页数:14
相关论文
共 64 条
  • [1] MAGNETIC-RESONANCE IMAGE-DIRECTED STEREOTAXIC NEUROSURGERY - USE OF IMAGE FUSION WITH COMPUTERIZED-TOMOGRAPHY TO ENHANCE SPATIAL ACCURACY
    ALEXANDER, E
    KOOY, HM
    VANHERK, M
    SCHWARTZ, M
    BARNES, PD
    TARBELL, N
    MULKERN, RV
    HOLUPKA, EJ
    LOEFFLER, JS
    [J]. JOURNAL OF NEUROSURGERY, 1995, 83 (02) : 271 - 276
  • [2] LEAST-SQUARES FITTING OF 2 3-D POINT SETS
    ARUN, KS
    HUANG, TS
    BLOSTEIN, SD
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1987, 9 (05) : 699 - 700
  • [3] AUDETTE M, 1999, SPIE IMAGE PROCESSIN, V3661, P110
  • [4] Auer L M, 1992, Acta Neurochir Suppl (Wien), V54, P34
  • [5] INTRAOPERATIVE ULTRASOUND (US) IMAGING - COMPARISON OF PATHOMORPHOLOGICAL FINDINGS IN US AND CT
    AUER, LM
    VANVELTHOVEN, V
    [J]. ACTA NEUROCHIRURGICA, 1990, 104 (3-4) : 84 - 95
  • [6] Systematic distortions in magnetic position digitizers
    Birkfellner, W
    Watzinger, F
    Wanschitz, F
    Enislidis, G
    Kollmann, C
    Rafolt, D
    Nowotny, R
    [J]. MEDICAL PHYSICS, 1998, 25 (11) : 2242 - 2248
  • [8] Polyvinyl alcohol cryogel: An ideal phantom material for MR studies of arterial flow and elasticity
    Chu, KC
    Rutt, BK
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (02) : 314 - 319
  • [9] Integrated MR and ultrasound imaging for improved image guidance in neurosurgery
    Comeau, RM
    Fenster, A
    Peters, TM
    [J]. MEDICAL IMAGING 1998: IMAGE PROCESSING, PTS 1 AND 2, 1998, 3338 : 747 - 754
  • [10] Intraoperative US in interactive image-guided neurosurgery
    Comeau, RM
    Fenster, A
    Peters, TM
    [J]. RADIOGRAPHICS, 1998, 18 (04) : 1019 - 1027