A rapid and reliable flow cytometric routine method for counting leucocytes in leucocyte-depleted platelet concentrates

被引:14
作者
Backteman, K
Ledent, E
Berlin, G
Ernerudh, J
机构
[1] Linkoping Univ Hosp, Dept Mol & Clin Med, Div Clin Immunol, S-58185 Linkoping, Sweden
[2] Linkoping Univ Hosp, Dept Mol & Clin Med, Div Transfus Med, S-58185 Linkoping, Sweden
关键词
flow cytometry; leucocytes; leucocyte depletion; platelet concentrates;
D O I
10.1046/j.1423-0410.2002.00196.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Objectives To ensure a proper quality control it is important to use a reliable method to count low numbers of leucocytes in leucocyte-reduced platelet concentrates (PCs). Materials and Methods A modified flow cytometric method for counting low numbers of leucocytes, based on a reference population contained in tubes with an exact number of fluorescent beads and staining with propidium iodide was used. To increase the number of events, the original sample volume was increased. Results There was a good correlation in the number of leucocytes (r = 0.99) between the modified flow cytometric method and microscopy of samples from unfiltered and expected numbers from serially diluted PCs. Samples from leucocyte-reduced PCs obtained by apheresis or filtered buffy coats showed no correlation between results from the modified flow cytometric method and microscopy (Nageotte). Conclusion Counting by microscopy gave a lower number of leucocytes than the modified flow cytometric method when counting a low number of cells. However, analysis of the serially diluted PCs proved that the modified flow cytometric method was reliable and rapid, making it suitable for clinical routine use.
引用
收藏
页码:29 / 34
页数:6
相关论文
共 12 条
[1]   Clinical trial and local process evaluation of an apheresis system for preparation of white cell-reduced platelet components [J].
Adams, MR ;
Dumont, LJ ;
McCall, M ;
Heaton, WA .
TRANSFUSION, 1998, 38 (10) :966-974
[2]   Flow cytometric determination of residual leucocytes in filter-depleted blood products: An evaluation of Becton-Dickinson's LeucoCOUNT systems [J].
Barclay, R ;
Walker, B ;
Allan, R ;
Reid, C ;
Duffin, E ;
Kane, E ;
Turner, M .
TRANSFUSION SCIENCE, 1998, 19 (04) :399-403
[3]   A FLOW CYTOMETRIC TECHNIQUE TO ACCURATELY MEASURE POST-FILTRATION WHITE BLOOD-CELL COUNTS [J].
BODENSTEINER, DC .
TRANSFUSION, 1989, 29 (07) :651-653
[4]   RELIABLE AND VERY SENSITIVE FLOW-CYTOMETRIC METHOD FOR COUNTING LOW LEUKOCYTE NUMBERS IN PLATELET CONCENTRATES [J].
DENEYS, V ;
MAZZON, AM ;
ROBERT, A ;
DUVILLIER, H ;
DEBRUYERE, M .
VOX SANGUINIS, 1994, 67 (02) :172-177
[5]  
Dumont LJ, 1996, CYTOMETRY, V26, P311, DOI 10.1002/(SICI)1097-0320(19961215)26:4<311::AID-CYTO12>3.3.CO
[6]  
2-D
[7]   SAMPLING ERRORS AND THE PRECISION ASSOCIATED WITH COUNTING VERY LOW NUMBERS OF WHITE CELLS IN BLOOD COMPONENTS [J].
DUMONT, LJ .
TRANSFUSION, 1991, 31 (05) :428-432
[8]   Principles of counting low numbers of leukocytes in leukoreduced blood components [J].
Dzik, S .
TRANSFUSION MEDICINE REVIEWS, 1997, 11 (01) :44-55
[9]   A multicenter study evaluating three methods for counting residual WBCs in WBC-reduced blood components: Nageotte hemocytometry, flow cytometry, and microfluorometry [J].
Dzik, S ;
Moroff, G ;
Dumont, L .
TRANSFUSION, 2000, 40 (05) :513-520
[10]   FLOW-CYTOMETRIC METHOD FOR COUNTING VERY LOW NUMBERS OF LEUKOCYTES IN PLATELET PRODUCTS [J].
DZIK, WH ;
RAGOSTA, A ;
CUSACK, WF .
VOX SANGUINIS, 1990, 59 (03) :153-159