Corrosion and viscous ash deposition of a rotary air preheater in a coal-fired power plant

被引:71
作者
Chen, Heng [1 ]
Pan, Peiyuan [1 ]
Shao, Huaishuang [1 ]
Wang, Yungang [1 ]
Zhao, Qinxin [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Key Lab Thermofluid Sci & Engn MOE, Xian 710049, Shaanxi, Peoples R China
基金
中国国家自然科学基金;
关键词
Air preheater; Coal-fired power plant; Dew point corrosion; Viscous ash deposition; Sulphuric acid condensation; DEW-POINT CORROSION; FAILURE ANALYSIS; TEMPERATURE; MECHANISM; TUBE;
D O I
10.1016/j.applthermaleng.2016.10.160
中图分类号
O414.1 [热力学];
学科分类号
070201 [理论物理];
摘要
The corrosion and viscous ash deposition characteristics of a rotary air preheater were investigated. Deposit samples and corroded heat transfer elements were taken from the air preheater of a 300 MW coal-fired power plant in China and analyzed by X-ray fluorescence, X-ray diffraction and scanning electron microscope equipped with energy dispersive X-ray spectroscopy. The results show that the serious corrosion and viscous ash deposition were both caused by sulphuric acid condensation rather than ammonium bisulfate deposition. The mechanisms of corrosion and viscous ash deposition were discussed and the coupling formation model of corrosion and viscous ash deposition was proposed. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:373 / 385
页数:13
相关论文
共 30 条
[2]
Behavior of a high-capacity steam boiler using heavy fuel oil Part II: cold-end corrosion [J].
Barreras, F ;
Barroso, J .
FUEL PROCESSING TECHNOLOGY, 2004, 86 (02) :107-121
[3]
Increase in the boiler's performance in terms of the acid dew point temperature:: Environmental advantages of replacing fuels [J].
Blanco, J. M. ;
Pena, F. .
APPLIED THERMAL ENGINEERING, 2008, 28 (07) :777-784
[4]
Analytical study of the effects of the clogging of a mechanical precipitator unit in air preheaters in a high-performance thermoelectric power plant based on available data [J].
Blanco, J. M. ;
Pena, F. .
JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2008, 130 (02)
[5]
Cen K, 1994, Prevention principle and calculation of ash deposition, slagging, wear and corrosion of boiler and heat exchanger
[6]
Che D.F., 2008, BOILER
[7]
Sulfuric acid dew point corrosion in waste heat boiler tube for copper smelting furnace [J].
Ebara, R. ;
Tanaka, F. ;
Kawasaki, M. .
ENGINEERING FAILURE ANALYSIS, 2013, 33 :29-36
[8]
Electrical Machinery Agency of China Power Company, 2002, AIR PREH POW PLANT B
[9]
SO3 Formation under Oxyfuel Combustion Conditions [J].
Fleig, Daniel ;
Andersson, Klas ;
Normann, Fredrik ;
Johnsson, Filip .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2011, 50 (14) :8505-8514
[10]
Experimental and sensitivity analysis of a rotary air preheater for the flue gas heat recovery [J].
Ghodsipour, N ;
Sadrameli, M .
APPLIED THERMAL ENGINEERING, 2003, 23 (05) :571-580