Fast Spin-Echo Triple-Echo Dixon: Initial Clinical Experience With A Novel Pulse Sequence for Fat-Suppressed T2-Weighted Abdominal MR Imaging

被引:20
作者
Low, Russell N. [1 ,2 ]
Ma, Jingfei [3 ]
Panchal, Neeraj [1 ,2 ]
机构
[1] Sharp & Childrens MRI Ctr, San Diego, CA 92123 USA
[2] San Diego Imaging Med Grp, San Diego, CA 92123 USA
[3] Univ Texas MD Anderson Canc Ctr, Houston, TX 77030 USA
关键词
MR imaging; 2-point Dixon; fat suppression; abdomen; INVERSION-RECOVERY; PHASE-CORRECTION; WATER; EFFICIENT; SEPARATION; DECOMPOSITION; FAILURE; PROTON; IMAGES; LIVER;
D O I
10.1002/jmri.21880
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate a prototype fast spin echo (FSE) triple-echo-Dixon (fTED) technique for breath-hold, fat-suppressed, T2-weighted abdominal imaging. Materials and Methods: Forty patients underwent breathhold T2-weighted abdominal imaging with fTED and conventional fast recovery (FR) FSE with chemical shift-selective saturation (CHESS). FRFSE and fTED images were compared for overall image quality, homogeneity of fat suppression. image sharpness, anatomic detail, and phase artifact. Depiction of disease was recorded separately for FRFSE and fTED images. Results: FTED successfully reconstructed water-only and fat-only images from source images in all 40 cases. Water and fat separation was perfect in 36 (0.90) patients. Homogeneity. of fat suppression was superior on the fTED images in 38 (0.95) of 40 cases. FTED images showed better anatomic detail in 27 (0.68), and less susceptibility artifact in 20 (0.50). FRFSE images showed less vascular pulsation artifact in 30 (0.75) cases, and less phase artifact in 21 (0.53) cases. There was no difference in depiction of disease for FRFSE and fTED images. Conclusion: FTED is a robust sequence providing breathhold T2-weighted images with superior fat suppression excellent image quality, and at least equal depiction of disease compared to conventional breath-hold T2-weighted FRFSE imaging.
引用
收藏
页码:569 / 577
页数:9
相关论文
共 31 条
[1]  
ANZAI Y, 1992, AM J NEURORADIOL, V13, P879
[2]   Liver: T2-weighted MR imaging with breath-hold fast-recovery optimized fast spin-echo compared with breath-hold half-Fourier and non-breath-hold respiratory-triggered fast spin-echo pulse sequences [J].
Augui, J ;
Vignaux, O ;
Argaud, C ;
Coste, J ;
Gouya, H ;
Legmann, P .
RADIOLOGY, 2002, 223 (03) :853-859
[3]  
Borges AR, 1997, J NEURO-OPHTHALMOL, V17, P12
[4]   MR IMAGING - CLINICAL USE OF THE INVERSION RECOVERY SEQUENCE [J].
BYDDER, GM ;
YOUNG, IR .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (04) :659-675
[5]   Pelvic imaging using a T1W fat-suppressed three-dimensional dual echo dixon technique at 3T [J].
Cornfeld, Daniel M. ;
Israel, Gary ;
McCarthy, Shirley M. ;
Weinreb, Jeffery C. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (01) :121-127
[6]   Body MRI using IDEAL [J].
Costa, Daniel N. ;
Pedrosa, Ivan ;
McKenzie, Charles ;
Reeder, Scott B. ;
Rofsky, Neil M. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (04) :1076-1084
[7]   Fat suppression in MR imaging: Techniques and pitfalls [J].
Delfaut, EM ;
Beltran, J ;
Johnson, G ;
Rousseau, J ;
Marchandise, X ;
Cotten, A .
RADIOGRAPHICS, 1999, 19 (02) :373-382
[8]   SIMPLE PROTON SPECTROSCOPIC IMAGING [J].
DIXON, WT .
RADIOLOGY, 1984, 153 (01) :189-194
[9]   Rapid MRI using a modified Dixon technique: a non-invasive and effective method for detection and monitoring of fatty metamorphosis of the liver [J].
Fishbein, MH ;
Stevens, WR .
PEDIATRIC RADIOLOGY, 2001, 31 (11) :806-809
[10]   INVERSION IN THE STEADY-STATE - CONTRAST OPTIMIZATION AND REDUCED IMAGING TIME WITH FAST 3-DIMENSIONAL INVERSION-RECOVERY - PREPARED GRE PULSE SEQUENCES [J].
FOO, TKF ;
SAWYER, AM ;
FAULKNER, WH ;
MILLS, DG .
RADIOLOGY, 1994, 191 (01) :85-90