Liver: T2-weighted MR imaging with breath-hold fast-recovery optimized fast spin-echo compared with breath-hold half-Fourier and non-breath-hold respiratory-triggered fast spin-echo pulse sequences

被引:37
作者
Augui, J
Vignaux, O
Argaud, C
Coste, J
Gouya, H
Legmann, P
机构
[1] Univ Paris 05, Hop Cochin, Dept Radiol, F-75674 Paris 14, France
[2] Univ Paris 05, Hop Cochin, Dept Biostat, F-75674 Paris, France
[3] GE Med Syst, Buc, France
关键词
liver neoplasms; MR; magnetic resonance (MR); comparative studies; pulse sequences;
D O I
10.1148/radiol.2233011011
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
At liver magnetic resonance (MR) imaging in 38 patients, a breath-hold T2-weighted fast spin-echo (SE) pulse sequence optimized with fast recovery was compared with a conventional respiratory-triggered fast SE sequence and a breath-hold single-shot fast SE sequence. Mean signal-to-noise ratios for liver and contrast-to-noise ratios for hepatic lesions were higher with the breath-hold fast-recovery fast SE sequence than with the respiratory-triggered fast SE sequence (P < .05). Breath-hold fast-recovery images displayed better lesion clarity than did single-shot fast SE images (P < .05) and fewer image artifacts than did respiratory-triggered fast SE images (P < .05). The ability to determine lesion size and the overall image quality was best with the breath-hold fast-recovery sequence (P < .05). These results may justify use of the breath-hold fast-recovery fast SE pulse sequence for first-line T2-weighted MR imaging of the liver. (C) RSNA, 2002.
引用
收藏
页码:853 / 859
页数:7
相关论文
共 15 条
  • [1] MR of focal liver lesions: Comparison of breath-hold and non-breath-hold hybrid RARE and conventional spin-echo T2-weighted pulse sequences
    Carpenter, KD
    Macaulay, SE
    Schulte, SJ
    Obregon, RG
    Nelson, RC
    Simon, HE
    Schmiedl, UP
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (04): : 596 - 602
  • [2] Hepatic T2-weighted MRI: A prospective comparison of sequences, including breath-hold, half-Fourier turbo spin echo (HASTE)
    Coates, GG
    Borrello, JA
    McFarland, EG
    Mirowitz, SA
    Brown, JJ
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1998, 8 (03): : 642 - 649
  • [3] FACTORS INFLUENCING CONTRAST IN FAST SPIN-ECHO MR IMAGING
    CONSTABLE, RT
    ANDERSON, AW
    ZHONG, J
    GORE, JC
    [J]. MAGNETIC RESONANCE IMAGING, 1992, 10 (04) : 497 - 511
  • [4] THE LOSS OF SMALL OBJECTS IN VARIABLE TE IMAGING - IMPLICATIONS FOR FSE, RARE, AND EPI
    CONSTABLE, RT
    GORE, JC
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (01) : 9 - 24
  • [5] Liver masses: Replacement of conventional T2-weighted spin-echo MR imaging with breath-hold MR imaging
    Gaa, J
    Hatabu, H
    Jenkins, RL
    Finn, JP
    Edelman, RR
    [J]. RADIOLOGY, 1996, 200 (02) : 459 - 464
  • [6] Single breath-hold T2-weighted MR imaging of the liver: Value of single-shot fast spin-echo and multishot spin-echo echoplanar imaging
    Hori, M
    Murakami, T
    Kim, T
    Kanematsu, M
    Tsuda, K
    Takahashi, S
    Takamura, M
    Hoshi, H
    Nakamura, H
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2000, 174 (05) : 1423 - 1431
  • [7] Focal hepatic lesion detection: Comparison of four fat-suppressed T2-weighted MR imaging pulse sequences
    Kanematsu, M
    Hoshi, H
    Itoh, K
    Murakami, T
    Hori, M
    Kondo, H
    Yokoyama, R
    Nakamura, H
    [J]. RADIOLOGY, 1999, 211 (02) : 363 - 371
  • [8] Focal hepatic lesion detection: Comparison of four T2-weighted MR imaging pulse sequences
    Kanematsu, M
    Hoshi, H
    Murakami, T
    Inaba, Y
    Hori, M
    Nandate, Y
    Yokoyama, R
    Nakamura, H
    [J]. RADIOLOGY, 1998, 206 (01) : 167 - 175
  • [9] Fast T2-weighted liver MR imaging: comparison among breath-hold turbo-spin-echo, HASTE, and inversion recovery (IR) HASTE sequences
    Lee, MG
    Jeong, YK
    Kim, JC
    Kang, EM
    Kim, PN
    Auh, YH
    Chien, D
    Laub, G
    [J]. ABDOMINAL IMAGING, 2000, 25 (01): : 93 - 99
  • [10] COMPARISON OF BREATH-HOLD FAST SPIN-ECHO AND CONVENTIONAL SPIN-ECHO PULSE SEQUENCES FOR T2-WEIGHTED MR-IMAGING OF LIVER-LESIONS
    RYDBERG, JN
    LOMAS, DJ
    COAKLEY, KJ
    HOUGH, DM
    EHMAN, RL
    RIEDERER, SJ
    [J]. RADIOLOGY, 1995, 194 (02) : 431 - 437