Focal hepatic lesion detection: Comparison of four T2-weighted MR imaging pulse sequences

被引:28
作者
Kanematsu, M
Hoshi, H
Murakami, T
Inaba, Y
Hori, M
Nandate, Y
Yokoyama, R
Nakamura, H
机构
[1] Gifu Univ, Sch Med, Dept Radiol, Gifu 500, Japan
[2] Osaka Univ, Sch Med, Dept Radiol, Osaka, Japan
[3] Aichi Canc Ctr, Dept Diagnost Radiol, Nagoya, Aichi 464, Japan
关键词
liver; MR; liver neoplasms; magnetic resonance (MR); pulse sequences;
D O I
10.1148/radiology.206.1.9423668
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate T2-weighted magnetic resonance (MR) imaging with conventional spin-echo, breath-hold fast spin-echo, respiratory-triggered fast spin-echo, and breath-hold multishot spin-echo echo-planar sequences for detection of focal hepatic lesions. MATERIALS AND METHODS: T2-weighted MR images obtained with the four sequences in 56 patients with 107 solid and 124 nonsolid lesions were retrospectively analyzed. Image review was conducted on a liver segment-by-segment basis; a total of 408 liver segments were reviewed separately and independently for solid and nonsolid lesions by three radiologists. Diagnostic accuracy was evaluated with receiver operating characteristic analysis. RESULTS: Lesions-to-liver contrast-to-noise ratio was highest with multishot echo-planar images of both solid and nonsolid lesions. Diagnostic accuracy for solid lesions was statistically significantly better with conventional spin-echo images than with any other type of image (P<.0001). Diagnostic accuracy for nonsolid lesions was statistically significantly better with respiratory-triggered fast spin-echo images than with any other type of image (P<.0001). Image quality was best with breath-hold fast spin-echo images. CONCLUSION: Conventional spin-echo MR imaging should not be replaced with breath-hold fast spin-echo or multishot spin-echo echo-planar imaging, despite the shorter acquisition times that are possible with the latter two sequences.
引用
收藏
页码:167 / 175
页数:9
相关论文
共 32 条
[1]   RESPIRATORY ORDERED PHASE ENCODING (ROPE) - A METHOD FOR REDUCING RESPIRATORY MOTION ARTIFACTS IN MR IMAGING [J].
BAILES, DR ;
GILDERDALE, DJ ;
BYDDER, GM ;
COLLINS, AG ;
FIRMIN, DN .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1985, 9 (04) :835-838
[2]   ECHO-PLANAR IMAGING OF THE LIVER WITH A STANDARD MR-IMAGING SYSTEM [J].
BUTTS, K ;
RIEDERER, SJ ;
EHMAN, RL ;
FELMLEE, JP ;
GRIMM, RC .
RADIOLOGY, 1993, 189 (01) :259-264
[3]   T2-WEIGHTED MR-IMAGING OF THE ABDOMEN - FAST SPIN-ECHO VS CONVENTIONAL SPIN-ECHO SEQUENCES [J].
CATASCA, JV ;
MIROWITZ, SA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (01) :61-67
[4]  
Couinaud C., 1957, FOIE ETUDES ANATOMIQ
[5]   SOME CONSIDERATIONS FOR MR IMAGING OF THE LIVER [J].
CROOKS, LE .
RADIOLOGY, 1991, 180 (03) :615-616
[6]  
Edelman RR, 1996, CLIN MAGNETIC RESONA, P302
[7]   CONTRAST OPTIMIZATION FOR THE DETECTION OF FOCAL HEPATIC-LESIONS BY MR IMAGING AT 1.5-T [J].
FOLEY, WD ;
KNEELAND, JB ;
CATES, JD ;
KELLMAN, GM ;
LAWSON, TL ;
MIDDLETON, WD ;
HENDRICK, RE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 149 (06) :1155-1160
[8]   DETECTION OF HEPATIC METASTASES - COMPARISON OF CONTRAST-ENHANCED CT, UNENHANCED MR IMAGING, AND IRON-OXIDE ENHANCED MR IMAGING [J].
FRETZ, CJ ;
STARK, DD ;
METZ, CE ;
ELIZONDO, G ;
WEISSLEDER, R ;
SHEN, JH ;
WITTENBERG, J ;
SIMEONE, J ;
FERRUCCI, JT .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1990, 155 (04) :763-770
[9]   Liver masses: Replacement of conventional T2-weighted spin-echo MR imaging with breath-hold MR imaging [J].
Gaa, J ;
Hatabu, H ;
Jenkins, RL ;
Finn, JP ;
Edelman, RR .
RADIOLOGY, 1996, 200 (02) :459-464
[10]   DIFFERENTIATION BETWEEN HEMANGIOMAS AND METASTASES OF THE LIVER WITH ULTRAFAST MR IMAGING - PRELIMINARY-RESULTS WITH T2 CALCULATIONS [J].
GOLDBERG, MA ;
SAINI, S ;
HAHN, PF ;
EGGLIN, TK ;
MUELLER, PR .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (04) :727-730