Analysis of human breath with micro extraction techniques and continuous monitoring of carbon dioxide concentration

被引:39
作者
Ma, Wei [1 ]
Liu, Xinyu [1 ]
Pawliszyn, Janusz [1 ]
机构
[1] Univ Waterloo, Dept Chem, Waterloo, ON N2L 3G1, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
membrane extraction with sorbent interface (MESI); CO2; sensor; internal standard; breath analysis; breath acetone;
D O I
10.1007/s00216-006-0595-y
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The detection of volatile organic compounds (VOCs) in human breath can be useful for the clinical routine diagnosis of several diseases in a non-invasive manner. Traditional methods of breath analysis have some major technical problems and limitations. Membrane extraction with a sorbent interface (MESI), however, has many advantages over current methods, including good selectivity and sensitivity, and is well suited for breath analysis. The aim of this project was to develop a simple and reproducible sampling device and method based on the MESI system for breath analysis. The feasibility and validity of the MESI system was tested with real human breath samples. Internal standard calibration methods were used for the quantitative analysis of various breath samples. Calibration curves for some main components (target analytes such as acetone and pentane) were determined in the research. The optimized stripping-side and feeding-side gas velocities were determined. The use of breath CO2 as an internal standard for the analysis of breath VOCs is an effective method to solve the difficulties associated with variations in the target analyte concentrations in a sample, which are attributed to mass losses and different breathing patterns of different subjects. In this study, the concentration of breath acetone was successfully expressed normalized to CO2 as in the alveolar air. Breath acetone of healthy males and females profiled at different times of the day was plotted using the MESI system, and results were consistent with the literature. This technique can be used for monitoring breath acetone concentrations of diabetic patients and for applications with other biomarker monitoring.
引用
收藏
页码:1398 / 1408
页数:11
相关论文
共 13 条
[1]  
FELDER RM, 1980, METHODS EXPT PHYS C, V16
[2]   Internal calibrant in the stripping gas. An approach to calibration of membrane extraction with a sorbent interface [J].
Liu, Xinyu ;
Pawliszyn, Janusz .
ANALYTICAL CHEMISTRY, 2006, 78 (09) :3001-3009
[3]   On-site monitoring of biogenic emissions from Eucalyptus dunnii leaves using membrane extraction with sorbent interface combined with a portable gas chromatograph system [J].
Liu, XY ;
Pawliszyn, R ;
Wang, LM ;
Pawliszyn, J .
ANALYST, 2004, 129 (01) :55-62
[4]   Breath analysis and monitoring by membrane extraction with sorbent interface [J].
Lord, H ;
Yu, YF ;
Segal, A ;
Pawliszyn, J .
ANALYTICAL CHEMISTRY, 2002, 74 (21) :5650-5657
[5]   Aqueous sample direct extraction and analysis by membrane extraction with a sorbent interface [J].
Luo, YZ ;
Adams, M ;
Pawliszyn, J .
ANALYST, 1997, 122 (12) :1461-1469
[6]  
LUO YZ, 2002, J ANAL CHEM+, V72, P1064
[7]   Diagnostic potential of breath analysis - focus on volatile organic compounds [J].
Miekisch, W ;
Schubert, JK ;
Noeldge-Schomburg, GFE .
CLINICA CHIMICA ACTA, 2004, 347 (1-2) :25-39
[8]  
NANDOR M, 2003, DIS MARKERS EXHALED
[9]  
Pawliszyn J., 2002, SAMPLING SAMPLE PREP
[10]   Variation in volatile organic compounds in the breath of normal humans [J].
Phillips, M ;
Herrera, J ;
Krishnan, S ;
Zain, M ;
Greenberg, J ;
Cataneo, RN .
JOURNAL OF CHROMATOGRAPHY B, 1999, 729 (1-2) :75-88