Intrinsic Gating for Small-Animal Computed Tomography A Robust ECG-Less Paradigm for Deriving Cardiac Phase Information and Functional Imaging

被引:31
作者
Dinkel, Julien [1 ]
Bartling, Soenke H. [2 ]
Kuntz, Jan [2 ]
Grasruck, Michael [4 ]
Kopp-Schneider, Annette [3 ]
Iwasaki, Masayoshi [5 ]
Dimmeler, Stefanie [5 ]
Gupta, Rajiv [6 ]
Semmler, Wolfhard [2 ]
Kauczor, Hans-Ulrich [1 ,7 ]
Kiessling, Fabian [2 ,8 ]
机构
[1] German Canc Res Ctr, Dept Radiol, D-69120 Heidelberg, Germany
[2] German Canc Res Ctr, Dept Med Phys Radiol, D-69120 Heidelberg, Germany
[3] German Canc Res Ctr, Dept Stat, D-69120 Heidelberg, Germany
[4] Siemens Med Solut, Forchheim, Germany
[5] Goethe Univ Frankfurt, Dept Mol Cardiol, D-6000 Frankfurt, Germany
[6] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[7] Univ Heidelberg Hosp, Dept Radiol, Heidelberg, Germany
[8] Rhein Westfal TH Aachen, Dept Expt Mol Imaging, Aachen, Germany
关键词
flat-panel detector; imaging; intrinsic gating; small-animal imaging; tomography;
D O I
10.1161/CIRCIMAGING.108.784702
中图分类号
R5 [内科学];
学科分类号
1002 [临床医学]; 100201 [内科学];
摘要
Background-A projection-based method of intrinsic cardiac gating in small-animal computed tomography imaging is presented. Methods and Results-In this method, which operates without external ECG monitoring, the gating reference signal is derived from the raw data of the computed tomography projections. After filtering, the derived gating reference signal is used to rearrange the projection images retrospectively into data sets representing different time points in the cardiac cycle during expiration. These time-stamped projection images are then used for tomographic reconstruction of different phases of the cardiac cycle. Intrinsic gating was evaluated in mice and rats and compared with extrinsic retrospective gating. An excellent agreement was achieved between ECG-derived gating signal and self-gating signal (coverage probability for a difference between the 2 measurements to be less than 5 ins was 89.2% in mice and 85.9% in rats). Functional parameters (ventricular volumes and ejection fraction) obtained from the intrinsic and the extrinsic data sets were not significantly different. The ease of use and reliability of intrinsic gating were demonstrated via a chemical stress test on 2 mice, in which the system performed flawlessly despite an increased heart rate. Because of intrinsic Gating, the image quality was improved to the extent that even the coronary arteries of mice could be Visualized in vivo despite a heart rate approaching 430 bpm. Feasibility of intrinsic gating for functional imaging and assessment of cardiac wall motion abnormalities was successfully tested in a mouse model of myocardial infarction. Conclusions-Our results demonstrate that self-gating using advanced software postprocessing of projection data promises to be a valuable tool for rodent computed tomography imaging and renders ECG gating with external electrodes superfluous. (Circ Cardiovasc Imaging. 2008;1:235-243.)
引用
收藏
页码:235 / 243
页数:9
相关论文
共 29 条
[1]
Badea C.T., 2005, Molecular Imaging, V4, DOI [10.1162/15353500200504187, DOI 10.1162/15353500200504187]
[2]
Intrinsic respiratory gating in small-animal CT [J].
Bartling, Soenke H. ;
Dinkel, Julien ;
Stiller, Wolfram ;
Grasruck, Michael ;
Madisch, Ijad ;
Kauczor, Hans-Ulrich ;
Semmler, Wolfhard ;
Gupta, Rajiv ;
Kiessling, Fabian .
EUROPEAN RADIOLOGY, 2008, 18 (07) :1375-1384
[3]
Retrospective motion Gating in small animal CT of mice and rats [J].
Bartling, Soenke H. ;
Stiller, Wolfram ;
Grasruck, Michael ;
Schmidt, Bernhard ;
Peschke, Peter ;
Semmler, Wolfhard ;
Kiessling, Fabian .
INVESTIGATIVE RADIOLOGY, 2007, 42 (10) :704-714
[4]
Small animal computed tomography Imaging [J].
Bartling, Soenke H. ;
Stiller, Wolfram ;
Semmler, Wolfhard ;
Kiessling, Fabian .
CURRENT MEDICAL IMAGING, 2007, 3 (01) :45-59
[5]
Boone John M, 2004, Mol Imaging, V3, P149, DOI 10.1162/1535350042380326
[6]
Estimation of the heart respiratory motion with applications for cone beam computed tomography imaging: A simulation study [J].
Buliev, IG ;
Badea, CT ;
Kolitsi, Z ;
Pallikarakis, N .
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2003, 7 (04) :404-411
[7]
Quantitative 3-dimensional echocardiography for accurate and rapid cardiac phenotype characterization in mice [J].
Dawson, D ;
Lygate, CA ;
Saunders, J ;
Schneider, JE ;
Ye, XJ ;
Hulbert, K ;
Noble, JA ;
Neubauer, S .
CIRCULATION, 2004, 110 (12) :1632-1637
[8]
DRAGOVA M, 2007, INVEST RADIAL, V42, P85
[9]
Validation of a raw data-based synchronization signal (kymogram) for phase-correlated cardiac image reconstruction [J].
Ertel, Dirk ;
Pflederer, Tobias ;
Achenbach, Stephan ;
Kachelriess, Marc ;
Steffen, Peter ;
Kalender, Willi A. .
EUROPEAN RADIOLOGY, 2008, 18 (02) :253-262
[10]
Prospective respiratory-gated micro-CT of free breathing rodents [J].
Ford, NL ;
Nikolov, HN ;
Norley, CJD ;
Thornton, MM ;
Foster, PJ ;
Drangova, M ;
Holdsworth, DW .
MEDICAL PHYSICS, 2005, 32 (09) :2888-2898