Effect of membrane composition and structure on solute removal and biocompatibility in hemodialysis

被引:142
作者
Clark, WR
Hamburger, RJ
Lysaght, MJ
机构
[1] Baxter Healthcare Corp, Div Renal, McGaw Pk, IL USA
[2] Indiana Univ, Sch Med, Div Nephrol, Indianapolis, IN USA
[3] Brown Univ, Artificial Organs Program, Providence, RI 02912 USA
关键词
acute renal failure; end-stage renal disease; cellulosic dialysis membranes; synthetic dialysis membranes; hemofiltration; biocompatibility; water flux;
D O I
10.1046/j.1523-1755.1999.00784.x
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Significant changes in extracorporeal membranes have occurred over the past five decades in which hemodialysis (HD) has been available as a therapy for both acute renal failure (ARF) and end-stage renal disease (ESRD). For cellulosic membranes, these changes have included a reduction in thickness, hydroxyl group substitution, and an increase in pore size. These modifications have resulted in enhanced efficiency of small solute removal, a broader spectrum of overall solute removal, and an attenuation of complement activation in comparison to the thick, unsubstituted cellulosic membranes of low permeability used in the early days of HD therapy. Synthetic membranes, originally developed specifically for use in high-flux HD and hemofiltration, have also evolved during this same time period. In fact, the initially clear distinction between low-flux regenerated cellulosic and high-flux synthetic membranes has become blurred, as membrane formulators have developed products designed to appeal to enthusiasts for both membrane formats. The purpose of this review is to characterize both the solute removal and biocompatibility characteristics of dialysis membranes according to their composition (that is, polymeric makeup) and structure. In this regard, the manner in which membrane biocompatibility interacts with flux is highlighted.
引用
收藏
页码:2005 / 2015
页数:11
相关论文
共 82 条
[1]   HETEROGENEITY IN GENTAMICIN CLEARANCE BETWEEN HIGH-EFFICIENCY HEMODIALYZERS [J].
AGARWAL, R ;
CRONIN, RE .
AMERICAN JOURNAL OF KIDNEY DISEASES, 1994, 23 (01) :47-51
[2]  
AKIZAWA T, 1995, CONTRIB NEPHROL, V113, P25
[3]  
Anderstam B, 1996, J AM SOC NEPHROL, V7, P2453
[4]  
ANDRADE JD, 1985, SURFACE INTERFACIAL, V2
[5]   Synthetically modified cellulose (SMC) - A cellulosic hemodialysis membrane with minimized complement activation [J].
Bowry, SK ;
Rintelen, TH .
ASAIO JOURNAL, 1998, 44 (05) :M579-M583
[6]  
Cheung AK, 1999, J AM SOC NEPHROL, V10, P117
[7]   ACTIVATION OF COMPLEMENT BY HEMODIALYSIS MEMBRANES - POLYACRYLONITRILE BINDS MORE C3A THAN CUPROPHAN [J].
CHEUNG, AK ;
PARKER, CJ ;
WILCOX, LA ;
JANATOVA, J .
KIDNEY INTERNATIONAL, 1990, 37 (04) :1055-1059
[8]   MEMBRANE ADSORPTION OF BETA(2)-MICROGLOBULIN - EQUILIBRIUM AND KINETIC CHARACTERIZATION [J].
CLARK, WR ;
MACIAS, WL ;
MOLITORIS, BA ;
WANG, NHL .
KIDNEY INTERNATIONAL, 1994, 46 (04) :1140-1146
[9]   PLASMA-PROTEIN ADSORPTION TO HIGHLY PERMEABLE HEMODIALYSIS MEMBRANES [J].
CLARK, WR ;
MACIAS, WL ;
MOLITORIS, BA ;
WANG, NHL .
KIDNEY INTERNATIONAL, 1995, 48 (02) :481-488
[10]  
Cohen G, 1997, KIDNEY INT, V52, pS79