Charge reduction electrospray mass spectrometry

被引:126
作者
Scalf, M [1 ]
Westphall, MS [1 ]
Smith, LM [1 ]
机构
[1] Univ Wisconsin, Dept Chem, Madison, WI 53706 USA
关键词
D O I
10.1021/ac990878c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new mass spectrometric technique, charge reduction electrospray mass spectrometry (CREMS), allowing the analysis of complex mixtures of biological molecules is described. The charge state of ions produced by electrospray ionization may be reduced in a controlled manner to yield predominantly singly charged ions through reactions with bipolar (i.e., both positively and negatively charged) ions generated using a Po-210 ex particle source. The electrospray-generated multiply charged ions undergo charge reduction in a "neutralization chamber" positioned before the entrance nozzle to the mass spectrometer. The ions are detected using a commercial orthogonal electrospray time-of-flight mass spectrometer, although the neutralization chamber can be adapted to virtually any mass analyzer. The CREMS results obtained exhibit a signal intensity drop-off with Increasing oligonucleotide size similar to that observed with matrix-assisted laser desorption/ionization mass spectrometry, Proton-transfer reactions were found to be responsible for reducing charge on proteins and oligonucleotides in both positive and negative ion mode.
引用
收藏
页码:52 / 60
页数:9
相关论文
共 63 条
  • [1] Analysis of oligonucleotides by HPLC-electrospray ionization mass spectrometry
    Apffel, A
    Chakel, JA
    Fischer, S
    Lichtenwalter, K
    Hancock, WS
    [J]. ANALYTICAL CHEMISTRY, 1997, 69 (07) : 1320 - 1325
  • [2] EPITAXIAL PROTEIN INCLUSION IN SINAPIC ACID CRYSTALS
    BEAVIS, RC
    BRIDSON, JN
    [J]. JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1993, 26 (03) : 442 - 447
  • [3] ATMOSPHERIC-PRESSURE IONIZATION MASS-SPECTROMETRY
    CARROLL, DI
    DZIDIC, I
    HORNING, EC
    STILLWELL, RN
    [J]. APPLIED SPECTROSCOPY REVIEWS, 1981, 17 (03) : 337 - 406
  • [4] ELECTROSPRAYING OF CONDUCTING LIQUIDS FOR MONODISPERSE AEROSOL GENERATION IN THE 4 NM TO 1.8 MU-M DIAMETER RANGE
    CHEN, DR
    PUI, DYH
    KAUFMAN, SL
    [J]. JOURNAL OF AEROSOL SCIENCE, 1995, 26 (06) : 963 - 977
  • [5] CHARGE-STATE REDUCTION OF OLIGONUCLEOTIDE NEGATIVE-IONS FROM ELECTROSPRAY-IONIZATION
    CHENG, XH
    GALE, DC
    UDSETH, HR
    SMITH, RD
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (03) : 586 - 593
  • [6] Clemmer DE, 1997, J MASS SPECTROM, V32, P577
  • [7] ELECTROSPRAY IONIZATION FOR MASS-SPECTROMETRY OF LARGE BIOMOLECULES
    FENN, JB
    MANN, M
    MENG, CK
    WONG, SF
    WHITEHOUSE, CM
    [J]. SCIENCE, 1989, 246 (4926) : 64 - 71
  • [8] MAXIMUM-ENTROPY DECONVOLUTION IN ELECTROSPRAY MASS-SPECTROMETRY
    FERRIGE, AG
    SEDDON, MJ
    JARVIS, S
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1991, 5 (08) : 374 - 377
  • [9] THE ANALYSIS OF MOCK DNA-SEQUENCING REACTIONS USING MATRIX-ASSISTED LASER-DESORPTION IONIZATION MASS-SPECTROMETRY
    FITZGERALD, MC
    ZHU, L
    SMITH, LM
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (10) : 895 - 897
  • [10] Fuchs N.A., 1963, Geofis. Pura E Appl, V56, P185, DOI [10.1007/BF01993343, DOI 10.1007/BF01993343]