Analysis of oligonucleotides by HPLC-electrospray ionization mass spectrometry

被引:310
作者
Apffel, A [1 ]
Chakel, JA [1 ]
Fischer, S [1 ]
Lichtenwalter, K [1 ]
Hancock, WS [1 ]
机构
[1] HEWLETT PACKARD CORP,CALIF ANALYT DIV,PALO ALTO,CA 94304
关键词
D O I
10.1021/ac960916h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new interface procedure has been developed that allows, for the first time, the high-efficiency analysis of synthetic oligonucleotides up to 75 bases by reversed-phase HPLC and on-line electrospray ionization mass spectrometry, For oligonucleotides up to 30 bases in length, single-base resolution can be obtained with low levels of cation adduct formation in the negative ion electrospray mass spectra, A key part of the method uses 1,1,1,3,3,3-hexafluoro-2-propanol as an additive to the HPLC mobile phase, adjusted to pH 7.0 with triethylamine. This novel additive results in both good HPLC separation and efficient electrospray ionization, The broad potential of this new method is demonstrated for synthetic homopolymers of thymidine (PolyT), fragments based on the pBR322 plasmid sequence, and phosphorothioate ester antisense oligonucleotides. This approach will be of particular utility for the characterization of DNA probes and PCR primers and quality control of antisense compounds such as phosphorothioates and their metabolites, as well as of materials used in clinical trials.
引用
收藏
页码:1320 / 1325
页数:6
相关论文
共 20 条
  • [1] ANTISENSE DNA OLIGONUCLEOTIDES .1. THE USE OF IONSPRAY TANDEM MASS-SPECTROMETRY FOR THE SEQUENCE VERIFICATION OF METHYLPHOSPHONATE OLIGODEOXYRIBONUCLEOTIDES
    BAKER, TR
    KEOUGH, T
    DOBSON, RLM
    RILEY, TA
    HASSELFIELD, JA
    HESSELBERTH, PE
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (03) : 190 - 194
  • [2] ANALYSIS OF DOUBLE-STRANDED OLIGONUCLEOTIDES BY ELECTROSPRAY MASS-SPECTROMETRY
    BAYER, E
    BAUER, T
    SCHMEER, K
    BLEICHER, K
    MALER, M
    GAUS, HJ
    [J]. ANALYTICAL CHEMISTRY, 1994, 66 (22) : 3858 - 3863
  • [3] VARIOUS FACTORS INFLUENCING THE SIGNAL INTENSITY OF OLIGONUCLEOTIDES IN ELECTROSPRAY MASS-SPECTROMETRY
    BLEICHER, K
    BAYER, E
    [J]. BIOLOGICAL MASS SPECTROMETRY, 1994, 23 (06) : 320 - 322
  • [4] ANALYSIS OF OLIGONUCLEOTIDES USING COUPLED HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ELECTROSPRAY MASS-SPECTROMETRY
    BLEICHER, K
    BAYER, E
    [J]. CHROMATOGRAPHIA, 1994, 39 (7-8) : 405 - 408
  • [5] LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY OF ANTISENSE OLIGONUCLEOTIDES
    BOTHNER, B
    CHATMAN, K
    SARKISIAN, M
    SIUZDAK, G
    [J]. BIOORGANIC & MEDICINAL CHEMISTRY LETTERS, 1995, 5 (23) : 2863 - 2868
  • [6] CHARGE-STATE REDUCTION OF OLIGONUCLEOTIDE NEGATIVE-IONS FROM ELECTROSPRAY-IONIZATION
    CHENG, XH
    GALE, DC
    UDSETH, HR
    SMITH, RD
    [J]. ANALYTICAL CHEMISTRY, 1995, 67 (03) : 586 - 593
  • [7] ANALYSIS OF POST-SYNTHETICALLY MODIFIED OLIGODEOXYNUCLEOTIDES BY ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY
    COLEMAN, RS
    KESICKI, EA
    ARTHUR, JC
    COTHAM, WE
    [J]. BIOORGANIC & MEDICINAL CHEMISTRY LETTERS, 1994, 4 (15) : 1869 - 1872
  • [8] SPECIFIC AND NONSPECIFIC DIMER FORMATION IN THE ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY OF OLIGONUCLEOTIDES
    DING, JM
    ANDEREGG, RJ
    [J]. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1995, 6 (03) : 159 - 164
  • [9] FRITZ HJ, 1978, BIOCHEMISTRY-US, V17, P1259
  • [10] SEQUENCING OF OLIGONUCLEOTIDES USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND ELECTROSPRAY MASS-SPECTROMETRY
    GLOVER, RP
    SWEETMAN, GMA
    FARMER, PB
    ROBERTS, GCK
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1995, 9 (10) : 897 - 901