3D images of paper obtained by phase-contrast X-ray micro tomography:: image quality and binarisation

被引:53
作者
Antoine, C [1 ]
Nygård, P
Gregersen, OW
Holmstad, R
Weitkamp, T
Rau, C
机构
[1] Norwegian Pulp & Paper Res Inst, N-7491 Trondheim, Norway
[2] Norwegian Univ Sci & Technol, Dept Chem Engn, N-7491 Trondheim, Norway
[3] European Synchrotron Radiat Facil, F-38043 Grenoble, France
关键词
3D paper structure; X-ray microtomography; phase contrast; segmentation;
D O I
10.1016/S0168-9002(02)01003-3
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A series of paper samples was investigated using high-resolution phase-contrast microtomography at the beamline 1D 22 of the European Synchrotron Radiation Facility (ESRF) in Grenoble, France. It was shown that X-ray microtomography is a non-destructive method suitable for high resolution depicting real 3D-paper structures. The method detects highly localised changes in the refractive index of the sample, such as fibre-pore interfaces. The resulting tomograms represented an outlined image of the fibre structure with an image resolution of 1 mum. Analyses were performed in dry state, but in addition some were done in wet state The raw data obtained were transformed into 3D images. The reconstructed slices were in general of rather good quality, even if both noise and ring-like artifacts were observed. These required special filtering efforts before a segmented binary volume could be obtained for further use of the data. This approach was made up of semi-automatic routines to convert the structure into a binary format. The resulting binary volumes can be used for further characterisation of the 3D-paper structure. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:392 / 402
页数:11
相关论文
共 28 条
[21]  
Rivers M., TUTORIAL INTRO XRAY
[22]  
Samuelsen EJ, 2001, J PULP PAP SCI, V27, P50
[23]   On the possibilities of x-ray phase contrast microimaging by coherent high-energy synchrotron radiation [J].
Snigirev, A ;
Snigireva, I ;
Kohn, V ;
Kuznetsov, S ;
Schelokov, I .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (12) :5486-5492
[24]   In-line holography and phase-contrast microtomography with high energy x-rays [J].
Spanne, P ;
Raven, C ;
Snigireva, I ;
Snigirev, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (03) :741-749
[25]   An imaging and microtomography facility at the ESRF beamline ID 22 [J].
Weitkamp, T ;
Raven, C ;
Snigirev, A .
DEVELOPMENTS IN X-RAY TOMOGRAPHY II, 1999, 3772 :311-317
[26]  
Xu L, 1997, APPITA J, V50, P325
[27]  
ZHANG XP, IEEE T IMAGE PROCESS, V20, P1020
[28]  
ZIOU D, 1997, 195 U SHERBR DEP MAT