Two-dimensional magnetic manipulation of microdroplets on a chip as a platform for bioanalytical applications

被引:116
作者
Lehmann, U. [1 ]
Hadjidj, S.
Parashar, V. K.
Vandevyver, C.
Rida, A.
Gijs, M. A. M.
机构
[1] Ecole Polytech Fed Lausanne, Inst Microelectron & Microsyst, CH-1015 Lausanne, Switzerland
[2] Ecole Polytech Fed Lausanne, Lab Chem Biotechnol, CH-1015 Lausanne, Switzerland
关键词
droplet; magnetism; actuation; lab-on-a-chip; microfluidics; ELISA;
D O I
10.1016/j.snb.2005.12.053
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Manipulating biological samples in microliter droplets has vast potential in molecular diagnostics. We present a system for the two-dimensional (213) magnetic manipulation of aqueous droplets suspended in silicone oil as a platform for on-chip bioanalysis. Superparamagnetic microparticles inside the droplets provide the means of the magnetic actuation. The droplets can be displaced, merged, mixed and separated on the chip without the use of external moving magnets or parts. In our system three-dimensional surface structures are replaced by an optimised hydrophilic/hydrophobic patterning of the chip surface to facilitating droplet splitting. We compare the functionality of the droplet manipulation system for magnetic particles of different sizes and demonstrate a dependency between particle size and performance. Finally we present the potential of the proposed system in droplet-based biomedical analysis by performing the dilution and detection of the secondary antibody of an enzyme-linked immuno-sorbent assay (ELISA) on-chip. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:457 / 463
页数:7
相关论文
共 21 条
[1]   Creating, transporting, cutting, and merging liquid droplets by electrowetting-based actuation for digital microfluidic circuits [J].
Cho, SK ;
Moon, HJ ;
Kim, CJ .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2003, 12 (01) :70-80
[2]   Manipulation of liquid droplets using amphiphilic, magnetic one-dimensional photonic crystal chaperones [J].
Dorvee, JR ;
Derfus, AM ;
Bhatia, SN ;
Sailor, MJ .
NATURE MATERIALS, 2004, 3 (12) :896-899
[3]  
Frohn A., 2000, EXP FLUID MECH
[4]   Magnetic bead handling on-chip: new opportunities for analytical applications [J].
Gijs, MAM .
MICROFLUIDICS AND NANOFLUIDICS, 2004, 1 (01) :22-40
[5]  
HADJIDJ S, 2004, THESIS EPFL
[6]   Handling of picoliter liquid samples in a poly(dimethylsiloxane)-based microfluidic device [J].
Hosokawa, K ;
Fujii, T ;
Endo, I .
ANALYTICAL CHEMISTRY, 1999, 71 (20) :4781-4785
[7]  
Hunt R.W., 1998, MEASURING COLOUR
[8]   Surface characterization of plasma-modified poly(ethylene terephthalate) film surfaces [J].
Inagaki, N ;
Narushim, K ;
Tuchida, N ;
Miyazak, K .
JOURNAL OF POLYMER SCIENCE PART B-POLYMER PHYSICS, 2004, 42 (20) :3727-3740
[9]   The science & applications of droplets in microfluidic devices - Foreword [J].
Jensen, K ;
Lee, A .
LAB ON A CHIP, 2004, 4 (04) :31N-32N
[10]  
Madou MJ., 2002, FUNDAMENTALS MICROFA