Axillary Lymph Nodes Suspicious for Breast Cancer Metastasis: Sampling with US-guided 14-Gauge Core-Needle Biopsy-Clinical Experience in 100 Patients

被引:149
作者
Abe, Hiroyuki [1 ]
Schmidt, Robert A. [1 ]
Kulkarni, Kirti [1 ]
Sennett, Charlene A. [1 ]
Mueller, Jeffrey S. [2 ]
Newstead, Gillian M. [1 ]
机构
[1] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
[2] Univ Chicago, Dept Pathol, Chicago, IL 60637 USA
关键词
SENTINEL NODE; ULTRASOUND; DISSECTION; ULTRASONOGRAPHY; DIAGNOSIS; LYMPHADENOPATHY; MULTICENTER; ASPIRATION; CARCINOMA; BENIGN;
D O I
10.1148/radiol.2493071483
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To study the clinical usefulness of ultrasonography (US)-guided core-needle biopsy (CNB) of axillary lymph nodes and the US-depicted abnormalities that may be used to predict nodal metastases. Materials and Methods: This retrospective study was HIPAA compliant and institutional review board approved; the requirement for informed patient consent was waived. US-guided 14-gauge CNB of abnormal axillary lymph nodes was performed in 100 of 144 patients with primary breast cancer who underwent US assessment of axillary lymph nodes. A biopsy needle with controllable action rather than a traditional throw-type needle was used. US findings were considered suspicious for metastasis if cortical thickening and/or non-hilar blood flow (NHBF) to the lymph node cortex was present. The absence of any discernible fatty hilum was also noted. Results: Nodal metastases were documented at CNB in 64 (64%) of the 100 patients. All 36 patients with negative biopsy results underwent subsequent sentinel lymph node biopsy (SLNB), which yielded negative findings in 32 (89%) patients and revealed metastasis in four (11%). All 44 patients who did not undergo CNB because of negative US results subsequently underwent SLNB, which revealed lymph node metastasis in 12 (27%) patients. Cortical thickening was found in 63 (79%) of the total of 80 metastatic nodes, but only a minority (n = 26 [32%]) of the nodes had an absent fatty hilum. NHBF to the cortex was detected in 52 (65%) metastatic nodes. Both absence of a fatty hilum (metastasis detected in 26 [93%] of 28 nodes) and cortical thickening combined with NHBF (metastasis detected in 52 [81%] of 64 nodes) had a high positive predictive value. No clinically important complications were encountered with the biopsy procedures. Conclusion: Axillary lymph nodes with abnormal US findings can be sampled with high accuracy and without major complications by using a modified 14-gauge CNB technique. (C) RSNA, 2008
引用
收藏
页码:41 / 49
页数:9
相关论文
共 33 条
[31]   Ultrasonography and fine-needle aspiration cytology can spare breast cancer patients unnecessary sentinel lymph node biopsy [J].
van Rijk, MC ;
Deurloo, EE ;
Nieweg, OE ;
Gilhuijs, KGA ;
Peterse, JL ;
Rutgers, EJT ;
Kröger, R ;
Kroon, BBR .
ANNALS OF SURGICAL ONCOLOGY, 2006, 13 (01) :31-35
[32]  
Yang WT, 1996, J ULTRAS MED, V15, P241
[33]   Patients with breast cancer: Differences in color Doppler flow and gray-scale US features of benign and malignant axillary lymph nodes [J].
Yang, WT ;
Chang, J ;
Metreweli, C .
RADIOLOGY, 2000, 215 (02) :568-573