Accuracy of caries detection with four storage phosphor systems and E-speed radiographs

被引:62
作者
Hintze, H [1 ]
Wenzel, A [1 ]
Frydenberg, M [1 ]
机构
[1] Aarhus Univ, Dept Oral Radiol, Royal Dent Coll, Fac Hlth Sci, DK-8000 Aarhus C, Denmark
关键词
dental caries; radiography; dental; digital; ROC curve; diagnostic test;
D O I
10.1038/sj.dmfr.4600686
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective: To evaluate the accuracy of caries detection using four intra-oral storage phosphor plate systems exposed with two different exposure times and one film system. Methods: Under in vitro and standardised conditions 365 approximal and 159 occlusal surfaces were radiographed using four storage phosphor plate systems: DenOptix, Cd-dent. Digora (blue and white plates) and one film system: Ektaspeed Plus. The plates were exposed twice with 10% and 25% of the time needed for the film. Four observers recorded approximal enamel/dentine and occlusal dentine caries using a five-point confidence scale. Caries presence was validated histologically and diagnostic accuracy of the systems by using ROC curve areas (A(z)). Results: The shorter exposure time for approximal caries. Digora(white) (A(z) = 0.68) and Ekta Plus (A(z) = 0.69) were significantly more accurate than the other systems (A(z) = 0.64-0.65). For occlusal caries using the same exposure time, no significant difference was found between the digital systems (A(z) = 0.76-0.77), which all showed to be significantly less accurate than Ekta Plus (A(z) = 0.81). Using the longer exposure time for approximal caries, no significant difference was found between DenOptix (A(z) = 0.68). Digora(blue) (A(z) = 0.69), Digora(white) (A(z) = 0.69) and Ekta Plus (A(z) = 0.69) which were all significantly more accurate than Cd-dent (A(z) = 0.65). For occlusal caries using the same exposure time, Digora(blue) (A(z) = 0.81) was the most significantly accurate of the digital systems. When approximal caries was the diagnostic task, the longer exposure time resulted in significantly higher accuracy with the DenOptix and Digora(blue) systems but not with the Cd-dent and Digora systems. For occlusal caries, the longer exposure time resulted in a significant improvement only with the Digora(blue) system. Conclusion: For approximal caries using the longer exposure time, no significant difference in diagnostic accuracy was found between DenOptix, Digora(blue) Digora(white) and Ekta Plus which were all significantly more accurate than the Cd-dent. For occlusal caries using the longer exposure time. Digora(blue) was found to be the most accurate of the digital systems. The exposure time had an influence on the diagnostic accuracy with the DenOptix and Digora(blue) systems for approximal and with the Digora(blue) System for occlusal caries detection.
引用
收藏
页码:170 / 175
页数:6
相关论文
共 22 条
[1]   Performance of RVGui sensor and Kodak Ektaspeed Plus film for proximal caries detection [J].
Abreu, M ;
Mol, A ;
Ludlow, JB .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2001, 91 (03) :381-385
[2]   Two- and three-dimensional imaging modalities for the detection of caries.: A comparison between film, digital radiography and tuned aperture computed tomography (TACT™) [J].
Abreu, M ;
Tyndall, DA ;
Platin, E ;
Ludlow, JB ;
Phillips, C .
DENTOMAXILLOFACIAL RADIOLOGY, 1999, 28 (03) :152-157
[3]   Marginal bone level buccal to mandibular molars in digital radiographs from charge-coupled device and storage phosphor systems - An in vitro study [J].
Borg, E ;
Grondahl, K ;
Grondahl, HG .
JOURNAL OF CLINICAL PERIODONTOLOGY, 1997, 24 (05) :306-312
[4]   Film and digital radiography for detection of simulated root resorption cavities [J].
Borg, E ;
Kallqvist, A ;
Grondahl, K ;
Grondahl, HG .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1998, 86 (01) :110-114
[5]   Subjective image quality of solid-state and photostimulable phosphor systems for digital intra-oral radiography [J].
Borg, E ;
Attaelmanan, A ;
Gröndahl, HG .
DENTOMAXILLOFACIAL RADIOLOGY, 2000, 29 (02) :70-75
[6]   Sensitometric and image quality performance of ''rapid'' intraoral film processing techniques [J].
Czajka, J ;
Rushton, VE ;
Shearer, AC ;
Horner, K .
BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (817) :49-58
[7]   In vitro comparison of Kodak Ultra-speed, Ektaspeed, and Ektaspeed Plus, and Agfa M2 comfort dental x-ray films for the detection of caries [J].
Hintze, H ;
Christoffersen, L ;
Wenzel, A .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1996, 81 (02) :240-244
[8]   Influence of the validation method on diagnostic accuracy for caries. A comparison of six digital and two conventional radiographic systems [J].
Hintze, H ;
Wenzel, A .
DENTOMAXILLOFACIAL RADIOLOGY, 2002, 31 (01) :44-49
[9]   IN-VITRO COMPARISON OF D-SPEED AND E-SPEED FILM RADIOGRAPHY, RVG, AND VISUALIX DIGITAL RADIOGRAPHY FOR THE DETECTION OF ENAMEL APPROXIMAL AND DENTINAL OCCLUSAL CARIES LESIONS [J].
HINTZE, H ;
WENZEL, A ;
JONES, C .
CARIES RESEARCH, 1994, 28 (05) :363-367
[10]   Storage-phosphor computed radiography versus film radiography in the detection of pathologic periradicular bone loss in cadavers [J].
Holtzmann, DJ ;
Johnson, WT ;
Southard, TE ;
Khademi, JA ;
Chang, PJ ;
Rivera, EM .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1998, 86 (01) :90-97