Software volumetric evaluation of doubling times for differentiating benign versus malignant pulmonary nodules

被引:106
作者
Revel, MP
Merlin, A
Peyrard, S
Triki, R
Couchon, S
Chatellier, G
Frija, G
机构
[1] Assistance Publ Hop Paris, Dept Radiol, F-75015 Paris, France
[2] Univ Paris Descartes, Fac Med, F-75015 Paris, France
[3] Hop Europeen Georges Pompidou, Dept Radiol, F-75015 Paris, France
[4] Hop Europeen Georges Pompidou, Ctr Invest Clin, F-75015 Paris, France
[5] Hop europeen George Pompidou, Unite Rech Clin, F-75015 Paris, France
关键词
chest; comparative studies; computer applications-3D; CT; lung; lung cancer; MDCT; oncologic imaging;
D O I
10.2214/AJR.05.1228
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of our study was to evaluate the reliability of software-calculated doubling times for discerning malignant versus benign nodules. MATERIALS AND METHODS. CT lung analysis volumetric software was used to retrospectively calculate the doubling times of 63 solid noncalcified nodules by comparing nodule volumes on baseline and follow-up CT scans obtained a median of 3.7 months apart. A final diagnosis based on validated criteria was available for all 63 nodules. All CT examinations were performed with 1.25-mm-thick slices on a four-detector unit. Taking 500 days as the upper value for malignancies, we evaluated whether the software-calculated doubling times could be used to distinguish malignant from benign solid nodules. We also examined whether the relative volume variation of benign nodules correlated with initial nodule size, interscan interval, or differences in contrast administration or exposure parameters between baseline and follow-up CT. RESULTS. There were 52 benign and 11 malignant nodules. Benign nodules had a median doubling time of 947 days and a mean relative volume variation of -4.4% (range, -50% to 38%). Malignant nodules had a median doubling time of 117 days and a mean relative volume variation of 102% (22-462%). The sensitivity, specificity, and negative and positive predictive values of the volumetric software for diagnosing malignancy were 91% (95% confidence interval [Cl], 0.59-1.00), 90% (95% Cl, 0.79-0.97), 98% (95% Cl, 0.89-1.00), and 67% (95% CI, 0.38-0.88), respectively. No correlation was found between the relative volume variation of benign nodules and their initial size, the interscan interval, or differences in contrast administration or exposure parameters between the two CT examinations. CONCLUSION. Software-calculated pulmonary nodule doubling times of more than 500 days have a 98% negative predictive value for the diagnosis of solid malignant pulmonary nodules. This method may be useful for diagnosing malignant pulmonary nodules on follow-up CT.
引用
收藏
页码:135 / 142
页数:8
相关论文
共 19 条
[1]   Seeking a home for a PET, Part 1 - Defining the appropriate place for positron emission tomography Imaging in the diagnosis of pulmonary nodules or masses [J].
Detterbeck, FC ;
Falen, S ;
Rivera, MP ;
Halle, JS ;
Socinski, MA .
CHEST, 2004, 125 (06) :2294-2299
[2]   Screening for early lung cancer with low-dose spiral CT: Prevalence in 817 asymptomatic smokers [J].
Diederich, S ;
Wormanns, D ;
Semik, M ;
Thomas, M ;
Lenzen, H ;
Roos, N ;
Heindel, W .
RADIOLOGY, 2002, 222 (03) :773-781
[3]   Solitary pulmonary nodules: Part I. Morphologic evaluation for differentiation of benign and malignant lesions [J].
Erasmus, JJ ;
Connolly, JE ;
McAdams, HP ;
Roggli, VL .
RADIOGRAPHICS, 2000, 20 (01) :43-58
[4]   Detection of pulmonary nodules by multislice computed tomography: improved detection rate with reduced slice thickness [J].
Fischbach, F ;
Knollmann, F ;
Griesshaber, V ;
Freund, T ;
Akkol, E ;
Felix, R .
EUROPEAN RADIOLOGY, 2003, 13 (10) :2378-2383
[5]   NATURAL-HISTORY OF LUNG-CANCER - REVIEW BASED ON RATES OF TUMOR-GROWTH [J].
GEDDES, DM .
BRITISH JOURNAL OF DISEASES OF THE CHEST, 1979, 73 (01) :1-17
[6]   Growth rate of small lung cancers detected on mass CT screening [J].
Hasegawa, M ;
Sone, S ;
Takashima, S ;
Li, F ;
Yang, ZG ;
Maruyama, Y ;
Watanabe, T .
BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (876) :1252-1259
[7]   CT screening for lung cancer: Suspiciousness of nodules according to size on baseline scans [J].
Henschke, CI ;
Yankelevitz, DF ;
Naidich, DP ;
McCauley, DI ;
McGuinness, G ;
Libby, DM ;
Smith, JP ;
Pasmantier, MW ;
Miettinen, OS .
RADIOLOGY, 2004, 231 (01) :164-168
[8]   Early Lung Cancer Action Project: overall design and findings from baseline screening [J].
Henschke, CI ;
McCauley, DI ;
Yankelevitz, DF ;
Naidich, DP ;
McGuinness, G ;
Miettinen, OS ;
Libby, DM ;
Pasmantier, MW ;
Koizumi, J ;
Altorki, NK ;
Smith, JP .
LANCET, 1999, 354 (9173) :99-105
[9]   Malignant versus benign nodules at CT screening for lung cancer: Comparison of thin-section CT findings [J].
Li, F ;
Sone, S ;
Abe, H ;
MacMhon, H ;
Doi, K .
RADIOLOGY, 2004, 233 (03) :793-798
[10]   Managing the small pulmonary nodule discovered by CT [J].
Libby, DM ;
Smith, JP ;
Altorki, NK ;
Pasmantier, MW ;
Yankelevitz, D ;
Henschke, CI .
CHEST, 2004, 125 (04) :1522-1529