Transthoracic echocardiographic visualization of coronary artery blood flow and assessment of coronary flow reserve in the right coronary artery: A first report of 3 patients

被引:10
作者
Tries, HP [1 ]
Lambertz, H [1 ]
Lethen, H [1 ]
机构
[1] Deutsch Klin Diagnost, Dept Cardiol, D-65191 Wiesbaden, Germany
关键词
D O I
10.1067/mje.2002.118525
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Assessment of coronary flow reserve (CFR) has proven to be an important diagnostic tool providing useful clinical and physiologic information about coronary artery function. In several studies, the transthoracic echocardiographic assessment of CFR, defined as a ratio of hyperemic to basal coronary flow velocity, was validated in the left anterior descending artery. But so far, the visualization of coronary flow and the measurement of CFR were limited to the mid and distal portion of the left anterior descending artery. introduction of a modified 2-chamber view enables the recording of coronary blood flow and the assessment of CFR in the posterior descending branch of the right coronary artery in selected patients. This report of 3 cases describes for the first time a method to visualize and measure coronary blood flow in the distal right coronary artery by precordial Doppler echocardiography.
引用
收藏
页码:739 / 742
页数:4
相关论文
共 16 条
[1]   Improved high-frequency transthoracic flow velocity measurement in the left anterior descending coronary artery after intravenous peripheral injection of levovist [J].
Bartel, T ;
Müller, S ;
Baumgart, D ;
Mathew, BT ;
Haude, M ;
Erbel, R .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1999, 12 (04) :252-256
[2]   Validation of a new noninvasive, method (contrast-enhanced transthoracic second harmonic echo Doppler) for the evaluation of coronary flow reserve - Comparison with intracoronary Doppler flow wire [J].
Caiati, C ;
Montaldo, C ;
Zedda, N ;
Montisci, R ;
Ruscazio, V ;
Lai, G ;
Cadeddu, J ;
Meloni, L ;
Iliceto, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1999, 34 (04) :1193-1200
[3]   New noninvasive method for coronary flow reserve assessment - Contrast-enhanced transthoracic second harmonic echo Doppler [J].
Caiati, C ;
Montaldo, C ;
Zedda, N ;
Bina, A ;
Iliceto, S .
CIRCULATION, 1999, 99 (06) :771-778
[4]   Transthoracic echocardiographic measurement of coronary blood flow and reserve [J].
Crowley, JJ ;
Shapiro, LM .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1997, 10 (04) :337-343
[5]   VALIDATION OF A DOPPLER GUIDE WIRE FOR INTRAVASCULAR MEASUREMENT OF CORONARY-ARTERY FLOW VELOCITY [J].
DOUCETTE, JW ;
CORL, PD ;
PAYNE, HM ;
FLYNN, AE ;
GOTO, M ;
NASSI, M ;
SEGAL, J .
CIRCULATION, 1992, 85 (05) :1899-1911
[7]   EFFECTS OF CORONARY STENOSES ON CORONARY FLOW RESERVE AND RESISTANCE [J].
GOULD, KL ;
LIPSCOMB, K .
AMERICAN JOURNAL OF CARDIOLOGY, 1974, 34 (01) :48-55
[8]   Potential use of transthoracic echocardiography in the assessment of coronary flow reserve [J].
Hildick-Smith, DJR ;
Shapiro, LM .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1999, 12 (07) :590-595
[9]   Noninvasive assessment of significant left anterior descending coronary artery stenosis by coronary flow velocity reserve with transthoracic color Doppler echocardiography [J].
Hozumi, T ;
Yoshida, K ;
Ogata, Y ;
Akasaka, T ;
Asami, Y ;
Takagi, T ;
Morioka, S .
CIRCULATION, 1998, 97 (16) :1557-1562
[10]   Noninvasive assessment of coronary flow velocity and coronary flow velocity reserve in the left anterior descending coronary artery by Doppler echocardiography - Comparison with invasive technique [J].
Hozumi, T ;
Yoshida, K ;
Akasaka, T ;
Asami, Y ;
Ogata, Y ;
Takagi, T ;
Kaji, S ;
Kawamoto, T ;
Ueda, Y ;
Morioka, S .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (05) :1251-1259