Friction, lubrication, and polymer transfer between UHMWPE and CoCrMo hip-implant materials: A fluorescence microscopy study

被引:28
作者
Crockett, Rowena [1 ]
Roba, Marcella [1 ,2 ]
Naka, Marco [2 ]
Gasser, Beat [3 ]
Delfosse, Daniel [4 ]
Frauchiger, Vinzenz [3 ]
Spencer, Nicholas D. [2 ]
机构
[1] Empa, Swiss Fed Inst Mat Sci & Technol, CH-8600 Dubendorf, Switzerland
[2] ETH, Dept Mat, Surface Sci & Technol Lab, CH-8093 Zurich, Switzerland
[3] Dr HC Robert Mathys Fdn, CH-2544 Bettlach, Switzerland
[4] Mathys AG Bettlach, CH-2544 Bettlach, Switzerland
关键词
artificial hip joints; albumin; friction; UHMWPE; CoCrMo; fluorescence; MOLECULAR-WEIGHT POLYETHYLENE; PROTEIN-LUBRICATION; JOINT SIMULATOR; WEAR RATES; IN-VITRO; PROSTHESES; BEHAVIOR; SURFACE; ARTHROPLASTY; CONSTITUENTS;
D O I
10.1002/jbm.a.32036
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The friction coefficients of CoCrMo sliding against UHMWPE and CoCrMo were measured in solutions of albumin and synovial fluid containing fluorescently labeled albumin. No fluorescence could be observed on the CoCrMo disc following incubation in labeled albumin or after sliding against CoCrMo. This was due to quenching of the fluorophore by the metal and indicated that a protein film thicker than 10 nm was not formed on the surface. A more complicated behavior was observed for UHMWPE sliding against CoCrMo. For each lubricating Solution and at each load, a bimodal distribution of steady-state friction values was observed, the friction coefficient either remaining constant or decreasing during the early stages of the measurement. As no quenching of the fluorophores Occurred on the UHMWPE surface, the fluorescence labeling method could be used to reveal polyethylene (PE) transfer and to show that it correlates with the friction coefficient: Low friction coefficients corresponded to a low density of PE spots on the CoCrMo Surface. In addition, it was found that the friction coefficients for UHMWPE sliding against CoCrMo in synovial fluid were not significantly different from those in phosphate-buffered saline (PBS), but that the addition of albumin to PBS did Cause a significant increase in the friction coefficient. (c) 2008 Wilely Periodicals, Inc. J Biomed Mater Res 89A: 1011-1018, 2009
引用
收藏
页码:1011 / 1018
页数:8
相关论文
共 36 条
[1]  
*AM AC ORTH SURG, 2001, IMPL WEAR TOT JOINT
[2]   EFFECT OF ROUGHNESS AND SLIDING SPEED ON THE WEAR AND FRICTION OF ULTRA-HIGH-MOLECULAR-WEIGHT POLYETHYLENE [J].
BARRETT, TS ;
STACHOWIAK, GW ;
BATCHELOR, AW .
WEAR, 1992, 153 (02) :331-350
[3]   Use of radiation in biomaterials science [J].
Benson, RS .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2002, 191 :752-757
[4]   AGGREGATION PHENOMENA IN EGG ALBUMIN SOLUTIONS AS DETERMINED BY LIGHT SCATTERING MEASUREMENTS [J].
BIER, M ;
NORD, FF .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1949, 35 (01) :17-23
[5]   FRICTION AND WEAR OF PTFE - A REVIEW [J].
BISWAS, SK ;
VIJAYAN, K .
WEAR, 1992, 158 (1-2) :193-211
[6]   Effect of counterface on the tribology of UHMWPE in the presence of proteins [J].
Chandrasekaran, M ;
Loh, NL .
WEAR, 2001, 250 (PART 1) :237-241
[7]  
Dedkov GV, 2000, PHYS STATUS SOLIDI A, V179, P3, DOI 10.1002/1521-396X(200005)179:1<3::AID-PSSA3>3.0.CO
[8]  
2-M
[9]   The clinical relevance of hip joint simulator testing: In vitro and in vivo comparisons [J].
Essner, A ;
Schmidig, G ;
Wang, A .
WEAR, 2005, 259 (259) :882-886
[10]   Computational hip joint simulator for wear and heat generation [J].
Fialho, Jorge C. ;
Fernandes, Paulo R. ;
Eca, Luis ;
Folgado, Joao .
JOURNAL OF BIOMECHANICS, 2007, 40 (11) :2358-2366