Tumoural perfusion as measured by dynamic computed tomography in head and neck carcinoma

被引:72
作者
Hermans, R
Lambin, P
Van der Goten, A
Van den Bogaert, W
Verbist, B
Weltens, C
Delaere, PR
机构
[1] Univ Hosp, Dept Radiol, B-3000 Louvain, Belgium
[2] Univ Hosp, Dept Radiat Oncol, Louvain, Belgium
[3] Univ Hosp, Dept Otorhinolaryngol Head & Neck Surg, Louvain, Belgium
关键词
blood flow-head and neck; therapeutic radiology-head and neck; neoplasms;
D O I
10.1016/S0167-8140(99)00132-2
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To investigate the intra- and interobserver variability, as well as the intra- and interpatient variability of CT-determined tumour perfusion in head and neck rumours, and to evaluate the preliminary value of this parameter as predictive factor of local failure after treatment by definitive radiotherapy. Materials and methods: In 41 patients the perfusion of a primary head and neck squamous cell carcinoma was estimated using dynamic CT. A 40-ml intravenous bolus of a low-osmolar non-ionic contrast agent was rapidly injected over 5 s (8 ml/s), while a dynamic acquisition of image data was obtained during the first pass at the level of the largest axial tumour surface. A time-density curve was constructed for the primary tumour and the carotid artery. The perfusion in the selected tumour region of interest was calculated by dividing the slope of the tumour-time density curve by the maximal value in arterial density. Tumour volume was calculated on the CT-images and correlated with perfusion rate. Results: The mean perfusion rate was 86.4 ml/min per 100 g (median, 80.6; SD, 43.05; range, 31.7-239.8 ml/min per 100 g). No systematic difference was found between the measurements performed by two independent observers. The intratumoural COV was 0.22, the intertumoural COV 0.37. No correlation was found with tumour volume. Ten out of 20 patients with a perfusion rate < 80 ml/min per 100 g were not locally controlled, while nine out of 21 patients with a value > 80 ml/min per 100 g did show a local failure (P = 0.19). Conclusions. CT-determined perfusion measurements of head and neck rumours are feasible. No correlation with tumour volume and a sufficiently large COV were found to consider this parameter as a possible prognostic factor for outcome after radiotherapy. More patients need to be investigated to rest the hypothesis that rumours with a low CT determined perfusion rate have a higher risk of local failure. (C) 1999 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:105 / 111
页数:7
相关论文
共 24 条
[1]  
ASPESTRAND F, 1994, ACTA RADIOL, V35, P217
[2]   INTERCAPILLARY DISTANCE MEASUREMENT AS AN INDICATOR OF HYPOXIA IN CARCINOMA OF THE CERVIX UTERI [J].
AWWAD, HK ;
ELNAGGAR, M ;
MOCKTAR, N ;
BARSOUM, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1986, 12 (08) :1329-1333
[3]   VOLUME DETERMINATIONS USING COMPUTED-TOMOGRAPHY [J].
BREIMAN, RS ;
BECK, JW ;
KOROBKIN, M ;
GLENNY, R ;
AKWARI, OE ;
HEASTON, DK ;
MOORE, AV ;
RAM, PC .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 138 (02) :329-333
[4]   Regional blood flow capillary permeability, and compartmental volumes: Measurement with dynamic CT - Initial experience [J].
Brix, G ;
Bahner, ML ;
Hoffmann, UJ ;
Horvath, A ;
Schreiber, W .
RADIOLOGY, 1999, 210 (01) :269-276
[5]  
BRIX G, 1994, ADV MRI CONTRAST, V2, P68
[6]  
Brizel DM, 1996, CANCER RES, V56, P941
[7]   Breast lesions: Correlation of contrast medium enhancement patterns on MR images with histopathologic findings and tumor angiogenesis [J].
Buadu, LD ;
Murakami, J ;
Murayama, S ;
Hashiguchi, N ;
Sakai, S ;
Masuda, K ;
Toyoshima, S ;
Kuroki, S ;
Ohno, S .
RADIOLOGY, 1996, 200 (03) :639-649
[8]   VASCULARIZATION AND CURABILITY OF STAGE-III AND STAGE-IV NASOPHARYNGEAL TUMORS [J].
DELIDES, GS ;
VENIZELOS, J ;
REVESZ, L .
JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 1988, 114 (03) :321-323
[9]  
FELDMANN HJ, 1991, TUMOR BLOOD SUPPLY M, P319
[10]   Non-invasive tumour perfusion measurement by dynamic CT: preliminary results [J].
Hermans, R ;
Lambin, P ;
VandenBogaert, W ;
Haustermans, K ;
VanderGoten, A ;
Baert, AL .
RADIOTHERAPY AND ONCOLOGY, 1997, 44 (02) :159-162