Dynamic hollow fiber protected liquid phase microextraction and quantification using gas chromatography combined with electron capture detection of organochlorine pesticides in green tea leaves and ready-to-drink tea

被引:76
作者
Huang, Shih-Pin [1 ]
Huang, Shang-Da [1 ]
机构
[1] Natl Tsing Hua Univ, Dept Chem, Hsinchu 30013, Taiwan
关键词
dynamic hollow fiber-LPME; organochlorine; GC-ECD;
D O I
10.1016/j.chroma.2006.09.027
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The dynamic hollow fiber protected liquid phase microextraction (DHFP-LPME) technique was evaluated for the extraction of organochlorine pesticides (OCPs) in green tea leaves and ready-to-drink tea prior to gas chromatography combined-electron capture detection (GC-ECD) analysis. A conventional microsyringe with a 1.5 cm length of hollow fiber attached to its needle was connected to a syringe pump to perform the extraction. The microsyringe was used as both the microextraction device and the sample introduction device for GC-ECD analysis. In this work, the organochlorine pesticides were extracted and condensed to a volume of 3 mu l of organic extracting solvent (1-octanol) confined within a 1.5 cm length of hollow fiber. The effects of extraction solvent, extraction time, sample agitation, plunger speed, and extraction temperature and salt concentration content on the extraction performance were also investigated. Good enrichments were achieved (34-297-fold) with this method, and good repeatabilities of extraction were obtained, with full name (RSDs) below 12.57%. Detection limits were much below 1 mu g l(-1) for ready-to-drink tea and much below 1 mu g g(-1) for green tea leaves. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:6 / 11
页数:6
相关论文
共 25 条
[1]   Development and application of polymer-coated hollow fiber membrane microextraction to the determination of organochlorine pesticides in water [J].
Basheer, C ;
Suresh, V ;
Renu, R ;
Lee, HK .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1033 (02) :213-220
[2]   Application of liquid-phase microextraction and gas chromatography-mass spectrometry for the determination of polychlorinated biphenyls in blood plasma [J].
Basheer, C ;
Lee, HK ;
Obbard, JP .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1022 (1-2) :161-169
[3]   Application of polyphenylmethylsiloxane coated fiber for solid-phase microextraction combined with microwave-assisted extraction for the determination of organochlorine pesticides in Chinese teas [J].
Cai, LS ;
Xing, J ;
Dong, L ;
Wu, CY .
JOURNAL OF CHROMATOGRAPHY A, 2003, 1015 (1-2) :11-21
[4]   Proportional mortality of dichloro-diphenyl-trichloroethane (DDT) workers: A preliminary report [J].
Cocco, P ;
Blair, A ;
Congia, P ;
Saba, G ;
Flore, C ;
Ecca, MR ;
Palmas, C .
ARCHIVES OF ENVIRONMENTAL HEALTH, 1997, 52 (04) :299-303
[5]  
DAVIES DL, 1995, SCI AM OCT, P144
[6]   Preliminary studies of a fast screening method for cocaine and cocaine metabolites in urine using hollow fibre membrane solvent microextraction (HFMSME) [J].
de Jager, LS ;
Andrews, ARJ .
ANALYST, 2001, 126 (08) :1298-1303
[7]  
HILEMAN E, 1994, CHEM ENG NEWS 0131, P19
[8]   Automated hollow fiber-protected dynamic liquid-phase microextraction of pesticides for gas chromatography - Mass spectrometric analysis [J].
Hou, L ;
Shen, G ;
Lee, HK .
JOURNAL OF CHROMATOGRAPHY A, 2003, 985 (1-2) :107-116
[9]   Solvent microextraction into a single drop [J].
Jeannot, MA ;
Cantwell, FF .
ANALYTICAL CHEMISTRY, 1996, 68 (13) :2236-2240
[10]   Mass transfer characteristics of solvent extraction into a single drop at the tip of a syringe needle [J].
Jeannot, MA ;
Cantwell, FF .
ANALYTICAL CHEMISTRY, 1997, 69 (02) :235-239